Environmental impacts on underground power distribution:
"This book studies the factors that affect the maximum current rating of subterranean power cables as well as various methods to maximize electrical current transmission by focusing on the latest tools, methodologies, and research in the field"--Provided by publisher.
Gespeichert in:
1. Verfasser: | |
---|---|
Format: | Elektronisch E-Book |
Sprache: | English |
Veröffentlicht: |
Hershey, Pennsylvania (701 E. Chocolate Avenue, Hershey, Pa., 17033, USA) :
IGI Global,
[2016]
|
Schlagworte: | |
Online-Zugang: | Volltext |
Zusammenfassung: | "This book studies the factors that affect the maximum current rating of subterranean power cables as well as various methods to maximize electrical current transmission by focusing on the latest tools, methodologies, and research in the field"--Provided by publisher. |
Beschreibung: | PDFs (405 pages) : illustrations. Also available in print. |
Format: | Mode of access: World Wide Web. |
Bibliographie: | Includes bibliographical references and index. |
ISBN: | 9781466665101 |
Zugangseinschränkungen: | Restricted to subscribers or individual electronic text purchasers. |
Internformat
MARC
LEADER | 00000nam a2200000 i 4500 | ||
---|---|---|---|
001 | ZDB-98-IGB-00108336 | ||
003 | IGIG | ||
005 | 20160118134337.0 | ||
006 | m eo d | ||
007 | cr bn |||m|||a | ||
008 | 160113s2016 paua fob 001 0 eng d | ||
010 | |z 2015037445 | ||
020 | |a 9781466665101 |q electronic | ||
020 | |z 9781466665095 |q print | ||
024 | 7 | |a 10.4018/978-1-4666-6509-5 |2 doi | |
035 | |a (CaBNVSL)gtp00564645 | ||
035 | |a (OCoLC)934770786 | ||
040 | |a CaBNVSL |b eng |e rda |c CaBNVSL |d CaBNVSL | ||
050 | 4 | |a TK3255 |b .G685 2016e | |
082 | 7 | |a 621.319/23 |2 23 | |
100 | 1 | |a Gouda, Osama El-Sayed, |d 1951- |e author. | |
245 | 1 | 0 | |a Environmental impacts on underground power distribution |c by Osama El-Sayed Gouda. |
264 | 1 | |a Hershey, Pennsylvania (701 E. Chocolate Avenue, Hershey, Pa., 17033, USA) : |b IGI Global, |c [2016] | |
300 | |a PDFs (405 pages) : |b illustrations. | ||
336 | |a text |2 rdacontent | ||
337 | |a electronic |2 isbdmedia | ||
338 | |a online resource |2 rdacarrier | ||
504 | |a Includes bibliographical references and index. | ||
505 | 0 | |a Underground power cable construction -- Cable standards -- Underground cables layout -- Dry band formation around underground cable -- Experimental analysis of backfill soils -- Experimental study of dry zone formation -- De-rating factor due to the dry-band formation -- Sheath bonding and grounding -- Effect of dry-zone formation around underground power cables on their ratings -- Factors affecting the sheath losses in single-core underground power cables -- Sheath overvoltage due to external faults in specially bonded cable system -- Testing of underground power cables -- Electrical and water treeing of cable insulation -- Partial discharges measurements for power cable insulation system -- Cable fault location. | |
506 | |a Restricted to subscribers or individual electronic text purchasers. | ||
520 | 3 | |a "This book studies the factors that affect the maximum current rating of subterranean power cables as well as various methods to maximize electrical current transmission by focusing on the latest tools, methodologies, and research in the field"--Provided by publisher. | |
530 | |a Also available in print. | ||
538 | |a Mode of access: World Wide Web. | ||
588 | |a Description based on title screen (IGI Global, viewed 01/13/2016). | ||
650 | 0 | |a Powerline ampacity. | |
650 | 0 | |a Underground electric lines |x Environmental aspects. | |
650 | 0 | |a Underground electric lines |x Reliability. | |
653 | |a Artificial backfill materials | ||
653 | |a Cable losses | ||
653 | |a Cross bonding system | ||
653 | |a Dry zones | ||
653 | |a Electric power transmission flux density | ||
653 | |a Thermal resistivity | ||
710 | 2 | |a IGI Global, |e publisher. | |
776 | 0 | |c (Original) |w (DLC)2015037445 | |
776 | 0 | 8 | |i Print version: |z 1466665092 |z 9781466665095 |w (DLC) 2015037445 |
856 | 4 | 0 | |l FWS01 |p ZDB-98-IGB |q FWS_PDA_IGB |u http://services.igi-global.com/resolvedoi/resolve.aspx?doi=10.4018/978-1-4666-6509-5 |3 Volltext |
912 | |a ZDB-98-IGB | ||
049 | |a DE-863 |
Datensatz im Suchindex
DE-BY-FWS_katkey | ZDB-98-IGB-00108336 |
---|---|
_version_ | 1816797075825754112 |
adam_text | |
any_adam_object | |
author | Gouda, Osama El-Sayed, 1951- |
author_facet | Gouda, Osama El-Sayed, 1951- |
author_role | aut |
author_sort | Gouda, Osama El-Sayed, 1951- |
author_variant | o e s g oes oesg |
building | Verbundindex |
bvnumber | localFWS |
callnumber-first | T - Technology |
callnumber-label | TK3255 |
callnumber-raw | TK3255 .G685 2016e |
callnumber-search | TK3255 .G685 2016e |
callnumber-sort | TK 43255 G685 42016E |
callnumber-subject | TK - Electrical and Nuclear Engineering |
collection | ZDB-98-IGB |
contents | Underground power cable construction -- Cable standards -- Underground cables layout -- Dry band formation around underground cable -- Experimental analysis of backfill soils -- Experimental study of dry zone formation -- De-rating factor due to the dry-band formation -- Sheath bonding and grounding -- Effect of dry-zone formation around underground power cables on their ratings -- Factors affecting the sheath losses in single-core underground power cables -- Sheath overvoltage due to external faults in specially bonded cable system -- Testing of underground power cables -- Electrical and water treeing of cable insulation -- Partial discharges measurements for power cable insulation system -- Cable fault location. |
ctrlnum | (CaBNVSL)gtp00564645 (OCoLC)934770786 |
dewey-full | 621.319/23 |
dewey-hundreds | 600 - Technology (Applied sciences) |
dewey-ones | 621 - Applied physics |
dewey-raw | 621.319/23 |
dewey-search | 621.319/23 |
dewey-sort | 3621.319 223 |
dewey-tens | 620 - Engineering and allied operations |
discipline | Elektrotechnik / Elektronik / Nachrichtentechnik |
format | Electronic eBook |
fullrecord | <?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>02978nam a2200529 i 4500</leader><controlfield tag="001">ZDB-98-IGB-00108336</controlfield><controlfield tag="003">IGIG</controlfield><controlfield tag="005">20160118134337.0</controlfield><controlfield tag="006">m eo d </controlfield><controlfield tag="007">cr bn |||m|||a</controlfield><controlfield tag="008">160113s2016 paua fob 001 0 eng d</controlfield><datafield tag="010" ind1=" " ind2=" "><subfield code="z"> 2015037445</subfield></datafield><datafield tag="020" ind1=" " ind2=" "><subfield code="a">9781466665101</subfield><subfield code="q">electronic</subfield></datafield><datafield tag="020" ind1=" " ind2=" "><subfield code="z">9781466665095</subfield><subfield code="q">print</subfield></datafield><datafield tag="024" ind1="7" ind2=" "><subfield code="a">10.4018/978-1-4666-6509-5</subfield><subfield code="2">doi</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(CaBNVSL)gtp00564645</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(OCoLC)934770786</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">CaBNVSL</subfield><subfield code="b">eng</subfield><subfield code="e">rda</subfield><subfield code="c">CaBNVSL</subfield><subfield code="d">CaBNVSL</subfield></datafield><datafield tag="050" ind1=" " ind2="4"><subfield code="a">TK3255</subfield><subfield code="b">.G685 2016e</subfield></datafield><datafield tag="082" ind1="7" ind2=" "><subfield code="a">621.319/23</subfield><subfield code="2">23</subfield></datafield><datafield tag="100" ind1="1" ind2=" "><subfield code="a">Gouda, Osama El-Sayed,</subfield><subfield code="d">1951-</subfield><subfield code="e">author.</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">Environmental impacts on underground power distribution </subfield><subfield code="c">by Osama El-Sayed Gouda.</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="a">Hershey, Pennsylvania (701 E. Chocolate Avenue, Hershey, Pa., 17033, USA) :</subfield><subfield code="b">IGI Global,</subfield><subfield code="c">[2016]</subfield></datafield><datafield tag="300" ind1=" " ind2=" "><subfield code="a">PDFs (405 pages) :</subfield><subfield code="b">illustrations.</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">text</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">electronic</subfield><subfield code="2">isbdmedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">online resource</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="504" ind1=" " ind2=" "><subfield code="a">Includes bibliographical references and index.</subfield></datafield><datafield tag="505" ind1="0" ind2=" "><subfield code="a">Underground power cable construction -- Cable standards -- Underground cables layout -- Dry band formation around underground cable -- Experimental analysis of backfill soils -- Experimental study of dry zone formation -- De-rating factor due to the dry-band formation -- Sheath bonding and grounding -- Effect of dry-zone formation around underground power cables on their ratings -- Factors affecting the sheath losses in single-core underground power cables -- Sheath overvoltage due to external faults in specially bonded cable system -- Testing of underground power cables -- Electrical and water treeing of cable insulation -- Partial discharges measurements for power cable insulation system -- Cable fault location.</subfield></datafield><datafield tag="506" ind1=" " ind2=" "><subfield code="a">Restricted to subscribers or individual electronic text purchasers.</subfield></datafield><datafield tag="520" ind1="3" ind2=" "><subfield code="a">"This book studies the factors that affect the maximum current rating of subterranean power cables as well as various methods to maximize electrical current transmission by focusing on the latest tools, methodologies, and research in the field"--Provided by publisher.</subfield></datafield><datafield tag="530" ind1=" " ind2=" "><subfield code="a">Also available in print.</subfield></datafield><datafield tag="538" ind1=" " ind2=" "><subfield code="a">Mode of access: World Wide Web.</subfield></datafield><datafield tag="588" ind1=" " ind2=" "><subfield code="a">Description based on title screen (IGI Global, viewed 01/13/2016).</subfield></datafield><datafield tag="650" ind1=" " ind2="0"><subfield code="a">Powerline ampacity.</subfield></datafield><datafield tag="650" ind1=" " ind2="0"><subfield code="a">Underground electric lines</subfield><subfield code="x">Environmental aspects.</subfield></datafield><datafield tag="650" ind1=" " ind2="0"><subfield code="a">Underground electric lines</subfield><subfield code="x">Reliability.</subfield></datafield><datafield tag="653" ind1=" " ind2=" "><subfield code="a">Artificial backfill materials</subfield></datafield><datafield tag="653" ind1=" " ind2=" "><subfield code="a">Cable losses</subfield></datafield><datafield tag="653" ind1=" " ind2=" "><subfield code="a">Cross bonding system</subfield></datafield><datafield tag="653" ind1=" " ind2=" "><subfield code="a">Dry zones</subfield></datafield><datafield tag="653" ind1=" " ind2=" "><subfield code="a">Electric power transmission flux density</subfield></datafield><datafield tag="653" ind1=" " ind2=" "><subfield code="a">Thermal resistivity</subfield></datafield><datafield tag="710" ind1="2" ind2=" "><subfield code="a">IGI Global,</subfield><subfield code="e">publisher.</subfield></datafield><datafield tag="776" ind1="0" ind2=" "><subfield code="c">(Original)</subfield><subfield code="w">(DLC)2015037445</subfield></datafield><datafield tag="776" ind1="0" ind2="8"><subfield code="i">Print version:</subfield><subfield code="z">1466665092</subfield><subfield code="z">9781466665095</subfield><subfield code="w">(DLC) 2015037445</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="l">FWS01</subfield><subfield code="p">ZDB-98-IGB</subfield><subfield code="q">FWS_PDA_IGB</subfield><subfield code="u">http://services.igi-global.com/resolvedoi/resolve.aspx?doi=10.4018/978-1-4666-6509-5</subfield><subfield code="3">Volltext</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">ZDB-98-IGB</subfield></datafield><datafield tag="049" ind1=" " ind2=" "><subfield code="a">DE-863</subfield></datafield></record></collection> |
id | ZDB-98-IGB-00108336 |
illustrated | Illustrated |
indexdate | 2024-11-26T14:51:49Z |
institution | BVB |
isbn | 9781466665101 |
language | English |
oclc_num | 934770786 |
open_access_boolean | |
owner | DE-863 DE-BY-FWS |
owner_facet | DE-863 DE-BY-FWS |
physical | PDFs (405 pages) : illustrations. Also available in print. |
psigel | ZDB-98-IGB |
publishDate | 2016 |
publishDateSearch | 2016 |
publishDateSort | 2016 |
publisher | IGI Global, |
record_format | marc |
spelling | Gouda, Osama El-Sayed, 1951- author. Environmental impacts on underground power distribution by Osama El-Sayed Gouda. Hershey, Pennsylvania (701 E. Chocolate Avenue, Hershey, Pa., 17033, USA) : IGI Global, [2016] PDFs (405 pages) : illustrations. text rdacontent electronic isbdmedia online resource rdacarrier Includes bibliographical references and index. Underground power cable construction -- Cable standards -- Underground cables layout -- Dry band formation around underground cable -- Experimental analysis of backfill soils -- Experimental study of dry zone formation -- De-rating factor due to the dry-band formation -- Sheath bonding and grounding -- Effect of dry-zone formation around underground power cables on their ratings -- Factors affecting the sheath losses in single-core underground power cables -- Sheath overvoltage due to external faults in specially bonded cable system -- Testing of underground power cables -- Electrical and water treeing of cable insulation -- Partial discharges measurements for power cable insulation system -- Cable fault location. Restricted to subscribers or individual electronic text purchasers. "This book studies the factors that affect the maximum current rating of subterranean power cables as well as various methods to maximize electrical current transmission by focusing on the latest tools, methodologies, and research in the field"--Provided by publisher. Also available in print. Mode of access: World Wide Web. Description based on title screen (IGI Global, viewed 01/13/2016). Powerline ampacity. Underground electric lines Environmental aspects. Underground electric lines Reliability. Artificial backfill materials Cable losses Cross bonding system Dry zones Electric power transmission flux density Thermal resistivity IGI Global, publisher. (Original) (DLC)2015037445 Print version: 1466665092 9781466665095 (DLC) 2015037445 FWS01 ZDB-98-IGB FWS_PDA_IGB http://services.igi-global.com/resolvedoi/resolve.aspx?doi=10.4018/978-1-4666-6509-5 Volltext |
spellingShingle | Gouda, Osama El-Sayed, 1951- Environmental impacts on underground power distribution Underground power cable construction -- Cable standards -- Underground cables layout -- Dry band formation around underground cable -- Experimental analysis of backfill soils -- Experimental study of dry zone formation -- De-rating factor due to the dry-band formation -- Sheath bonding and grounding -- Effect of dry-zone formation around underground power cables on their ratings -- Factors affecting the sheath losses in single-core underground power cables -- Sheath overvoltage due to external faults in specially bonded cable system -- Testing of underground power cables -- Electrical and water treeing of cable insulation -- Partial discharges measurements for power cable insulation system -- Cable fault location. Powerline ampacity. Underground electric lines Environmental aspects. Underground electric lines Reliability. |
title | Environmental impacts on underground power distribution |
title_auth | Environmental impacts on underground power distribution |
title_exact_search | Environmental impacts on underground power distribution |
title_full | Environmental impacts on underground power distribution by Osama El-Sayed Gouda. |
title_fullStr | Environmental impacts on underground power distribution by Osama El-Sayed Gouda. |
title_full_unstemmed | Environmental impacts on underground power distribution by Osama El-Sayed Gouda. |
title_short | Environmental impacts on underground power distribution |
title_sort | environmental impacts on underground power distribution |
topic | Powerline ampacity. Underground electric lines Environmental aspects. Underground electric lines Reliability. |
topic_facet | Powerline ampacity. Underground electric lines Environmental aspects. Underground electric lines Reliability. |
url | http://services.igi-global.com/resolvedoi/resolve.aspx?doi=10.4018/978-1-4666-6509-5 |
work_keys_str_mv | AT goudaosamaelsayed environmentalimpactsonundergroundpowerdistribution AT igiglobal environmentalimpactsonundergroundpowerdistribution |