Why Are So Many Water Points in Nigeria Non-Functional?: An Empirical Analysis of Contributing Factors
This paper utilizes information from the 2015 Nigeria National Water and Sanitation Survey to identify the extent, timing, as well as reasons for the failure of water points. The paper finds that more than 38 percent of all improved water points are nonfunctional. The results indicate that nearly 27...
Gespeichert in:
1. Verfasser: | |
---|---|
Format: | Elektronisch E-Book |
Sprache: | English |
Veröffentlicht: |
Washington, D.C
The World Bank
2018
|
Schriftenreihe: | World Bank E-Library Archive
|
Online-Zugang: | Volltext |
Zusammenfassung: | This paper utilizes information from the 2015 Nigeria National Water and Sanitation Survey to identify the extent, timing, as well as reasons for the failure of water points. The paper finds that more than 38 percent of all improved water points are nonfunctional. The results indicate that nearly 27 percent of the water points are likely to fail in the first year of construction, while nearly 40 percent are likely to fail in the long run (after 8-10 years). The paper considers the reasons behind these failures, looking at whether they can or cannot be controlled. During the first year, a water point's location-the political region and underlying hydrogeology-has the greatest impact on functionality. Other factors-specifically, those that can be controlled in the design, implementation, and operational stages-also contribute significantly. As water points age, their likelihood of failure is best predicted by factors that cannot be modified, as well as by the technology used. The paper concludes that, to improve the sustainability of water points, much can be done at the design, implementation, and operational stages. Over time, technology upgrades are important |
Beschreibung: | 1 Online-Ressource (37 Seiten) |
DOI: | 10.1596/1813-9450-8388 |
Internformat
MARC
LEADER | 00000nmm a2200000zc 4500 | ||
---|---|---|---|
001 | BV048273897 | ||
003 | DE-604 | ||
007 | cr|uuu---uuuuu | ||
008 | 220609s2018 |||| o||u| ||||||eng d | ||
024 | 7 | |a 10.1596/1813-9450-8388 |2 doi | |
035 | |a (ZDB-1-WBA)NLM011148195 | ||
035 | |a (OCoLC)1334025314 | ||
035 | |a (DE-599)GBVNLM011148195 | ||
040 | |a DE-604 |b ger |e rda | ||
041 | 0 | |a eng | |
049 | |a DE-12 |a DE-521 |a DE-573 |a DE-523 |a DE-Re13 |a DE-19 |a DE-355 |a DE-703 |a DE-91 |a DE-706 |a DE-29 |a DE-M347 |a DE-473 |a DE-824 |a DE-20 |a DE-739 |a DE-1043 |a DE-863 |a DE-862 | ||
100 | 1 | |a Andres, Luis |e Verfasser |4 aut | |
245 | 1 | 0 | |a Why Are So Many Water Points in Nigeria Non-Functional? |b An Empirical Analysis of Contributing Factors |c Andres, Luis |
264 | 1 | |a Washington, D.C |b The World Bank |c 2018 | |
300 | |a 1 Online-Ressource (37 Seiten) | ||
336 | |b txt |2 rdacontent | ||
337 | |b c |2 rdamedia | ||
338 | |b cr |2 rdacarrier | ||
490 | 0 | |a World Bank E-Library Archive | |
520 | |a This paper utilizes information from the 2015 Nigeria National Water and Sanitation Survey to identify the extent, timing, as well as reasons for the failure of water points. The paper finds that more than 38 percent of all improved water points are nonfunctional. The results indicate that nearly 27 percent of the water points are likely to fail in the first year of construction, while nearly 40 percent are likely to fail in the long run (after 8-10 years). The paper considers the reasons behind these failures, looking at whether they can or cannot be controlled. During the first year, a water point's location-the political region and underlying hydrogeology-has the greatest impact on functionality. Other factors-specifically, those that can be controlled in the design, implementation, and operational stages-also contribute significantly. As water points age, their likelihood of failure is best predicted by factors that cannot be modified, as well as by the technology used. The paper concludes that, to improve the sustainability of water points, much can be done at the design, implementation, and operational stages. Over time, technology upgrades are important | ||
700 | 1 | |a Andres, Luis |4 oth | |
700 | 1 | |a Chellaraj, Gnanaraj |4 oth | |
700 | 1 | |a Grabinsky, Jonathan |4 oth | |
700 | 1 | |a Gupta, Basab Das |4 oth | |
700 | 1 | |a Joseph, George |4 oth | |
776 | 0 | 8 | |i Erscheint auch als |n Druck-Ausgabe |a Andres, Luis |t Why Are So Many Water Points in Nigeria Non-Functional? An Empirical Analysis of Contributing Factors |d Washington, D.C : The World Bank, 2018 |
856 | 4 | 0 | |u https://doi.org/10.1596/1813-9450-8388 |x Verlag |z kostenfrei |3 Volltext |
912 | |a ZDB-1-WBA | ||
943 | 1 | |a oai:aleph.bib-bvb.de:BVB01-033654092 |
Datensatz im Suchindex
_version_ | 1812671818845126656 |
---|---|
adam_text | |
adam_txt | |
any_adam_object | |
any_adam_object_boolean | |
author | Andres, Luis |
author_facet | Andres, Luis |
author_role | aut |
author_sort | Andres, Luis |
author_variant | l a la |
building | Verbundindex |
bvnumber | BV048273897 |
collection | ZDB-1-WBA |
ctrlnum | (ZDB-1-WBA)NLM011148195 (OCoLC)1334025314 (DE-599)GBVNLM011148195 |
discipline | Wirtschaftswissenschaften |
discipline_str_mv | Wirtschaftswissenschaften |
doi_str_mv | 10.1596/1813-9450-8388 |
format | Electronic eBook |
fullrecord | <?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>00000nmm a2200000zc 4500</leader><controlfield tag="001">BV048273897</controlfield><controlfield tag="003">DE-604</controlfield><controlfield tag="007">cr|uuu---uuuuu</controlfield><controlfield tag="008">220609s2018 |||| o||u| ||||||eng d</controlfield><datafield tag="024" ind1="7" ind2=" "><subfield code="a">10.1596/1813-9450-8388</subfield><subfield code="2">doi</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(ZDB-1-WBA)NLM011148195</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(OCoLC)1334025314</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-599)GBVNLM011148195</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-604</subfield><subfield code="b">ger</subfield><subfield code="e">rda</subfield></datafield><datafield tag="041" ind1="0" ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="049" ind1=" " ind2=" "><subfield code="a">DE-12</subfield><subfield code="a">DE-521</subfield><subfield code="a">DE-573</subfield><subfield code="a">DE-523</subfield><subfield code="a">DE-Re13</subfield><subfield code="a">DE-19</subfield><subfield code="a">DE-355</subfield><subfield code="a">DE-703</subfield><subfield code="a">DE-91</subfield><subfield code="a">DE-706</subfield><subfield code="a">DE-29</subfield><subfield code="a">DE-M347</subfield><subfield code="a">DE-473</subfield><subfield code="a">DE-824</subfield><subfield code="a">DE-20</subfield><subfield code="a">DE-739</subfield><subfield code="a">DE-1043</subfield><subfield code="a">DE-863</subfield><subfield code="a">DE-862</subfield></datafield><datafield tag="100" ind1="1" ind2=" "><subfield code="a">Andres, Luis</subfield><subfield code="e">Verfasser</subfield><subfield code="4">aut</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">Why Are So Many Water Points in Nigeria Non-Functional?</subfield><subfield code="b">An Empirical Analysis of Contributing Factors</subfield><subfield code="c">Andres, Luis</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="a">Washington, D.C</subfield><subfield code="b">The World Bank</subfield><subfield code="c">2018</subfield></datafield><datafield tag="300" ind1=" " ind2=" "><subfield code="a">1 Online-Ressource (37 Seiten)</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="b">txt</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="b">c</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="b">cr</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="490" ind1="0" ind2=" "><subfield code="a">World Bank E-Library Archive</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">This paper utilizes information from the 2015 Nigeria National Water and Sanitation Survey to identify the extent, timing, as well as reasons for the failure of water points. The paper finds that more than 38 percent of all improved water points are nonfunctional. The results indicate that nearly 27 percent of the water points are likely to fail in the first year of construction, while nearly 40 percent are likely to fail in the long run (after 8-10 years). The paper considers the reasons behind these failures, looking at whether they can or cannot be controlled. During the first year, a water point's location-the political region and underlying hydrogeology-has the greatest impact on functionality. Other factors-specifically, those that can be controlled in the design, implementation, and operational stages-also contribute significantly. As water points age, their likelihood of failure is best predicted by factors that cannot be modified, as well as by the technology used. The paper concludes that, to improve the sustainability of water points, much can be done at the design, implementation, and operational stages. Over time, technology upgrades are important</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Andres, Luis</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Chellaraj, Gnanaraj</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Grabinsky, Jonathan</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Gupta, Basab Das</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Joseph, George</subfield><subfield code="4">oth</subfield></datafield><datafield tag="776" ind1="0" ind2="8"><subfield code="i">Erscheint auch als</subfield><subfield code="n">Druck-Ausgabe</subfield><subfield code="a">Andres, Luis</subfield><subfield code="t">Why Are So Many Water Points in Nigeria Non-Functional? An Empirical Analysis of Contributing Factors</subfield><subfield code="d">Washington, D.C : The World Bank, 2018</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">https://doi.org/10.1596/1813-9450-8388</subfield><subfield code="x">Verlag</subfield><subfield code="z">kostenfrei</subfield><subfield code="3">Volltext</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">ZDB-1-WBA</subfield></datafield><datafield tag="943" ind1="1" ind2=" "><subfield code="a">oai:aleph.bib-bvb.de:BVB01-033654092</subfield></datafield></record></collection> |
id | DE-604.BV048273897 |
illustrated | Not Illustrated |
index_date | 2024-07-03T20:00:10Z |
indexdate | 2024-10-12T04:02:37Z |
institution | BVB |
language | English |
oai_aleph_id | oai:aleph.bib-bvb.de:BVB01-033654092 |
oclc_num | 1334025314 |
open_access_boolean | 1 |
owner | DE-12 DE-521 DE-573 DE-523 DE-Re13 DE-BY-UBR DE-19 DE-BY-UBM DE-355 DE-BY-UBR DE-703 DE-91 DE-BY-TUM DE-706 DE-29 DE-M347 DE-473 DE-BY-UBG DE-824 DE-20 DE-739 DE-1043 DE-863 DE-BY-FWS DE-862 DE-BY-FWS |
owner_facet | DE-12 DE-521 DE-573 DE-523 DE-Re13 DE-BY-UBR DE-19 DE-BY-UBM DE-355 DE-BY-UBR DE-703 DE-91 DE-BY-TUM DE-706 DE-29 DE-M347 DE-473 DE-BY-UBG DE-824 DE-20 DE-739 DE-1043 DE-863 DE-BY-FWS DE-862 DE-BY-FWS |
physical | 1 Online-Ressource (37 Seiten) |
psigel | ZDB-1-WBA |
publishDate | 2018 |
publishDateSearch | 2018 |
publishDateSort | 2018 |
publisher | The World Bank |
record_format | marc |
series2 | World Bank E-Library Archive |
spellingShingle | Andres, Luis Why Are So Many Water Points in Nigeria Non-Functional? An Empirical Analysis of Contributing Factors |
title | Why Are So Many Water Points in Nigeria Non-Functional? An Empirical Analysis of Contributing Factors |
title_auth | Why Are So Many Water Points in Nigeria Non-Functional? An Empirical Analysis of Contributing Factors |
title_exact_search | Why Are So Many Water Points in Nigeria Non-Functional? An Empirical Analysis of Contributing Factors |
title_exact_search_txtP | Why Are So Many Water Points in Nigeria Non-Functional? An Empirical Analysis of Contributing Factors |
title_full | Why Are So Many Water Points in Nigeria Non-Functional? An Empirical Analysis of Contributing Factors Andres, Luis |
title_fullStr | Why Are So Many Water Points in Nigeria Non-Functional? An Empirical Analysis of Contributing Factors Andres, Luis |
title_full_unstemmed | Why Are So Many Water Points in Nigeria Non-Functional? An Empirical Analysis of Contributing Factors Andres, Luis |
title_short | Why Are So Many Water Points in Nigeria Non-Functional? |
title_sort | why are so many water points in nigeria non functional an empirical analysis of contributing factors |
title_sub | An Empirical Analysis of Contributing Factors |
url | https://doi.org/10.1596/1813-9450-8388 |
work_keys_str_mv | AT andresluis whyaresomanywaterpointsinnigerianonfunctionalanempiricalanalysisofcontributingfactors AT chellarajgnanaraj whyaresomanywaterpointsinnigerianonfunctionalanempiricalanalysisofcontributingfactors AT grabinskyjonathan whyaresomanywaterpointsinnigerianonfunctionalanempiricalanalysisofcontributingfactors AT guptabasabdas whyaresomanywaterpointsinnigerianonfunctionalanempiricalanalysisofcontributingfactors AT josephgeorge whyaresomanywaterpointsinnigerianonfunctionalanempiricalanalysisofcontributingfactors |