The Supply of Medical Isotopes: An Economic Diagnosis and Possible Solutions
This report explores the main reasons behind the unreliable supply of Technetium-99m (Tc-99m) in health-care systems and policy options to address the issue. Tc-99m is used in 85% of nuclear medicine diagnostic scans performed worldwide - around 30 million patient examinations every year. These scan...
Gespeichert in:
Format: | Elektronisch E-Book |
---|---|
Sprache: | English |
Veröffentlicht: |
Paris
OECD Publishing
2019
|
Schlagworte: | |
Online-Zugang: | kostenfrei |
Zusammenfassung: | This report explores the main reasons behind the unreliable supply of Technetium-99m (Tc-99m) in health-care systems and policy options to address the issue. Tc-99m is used in 85% of nuclear medicine diagnostic scans performed worldwide - around 30 million patient examinations every year. These scans allow diagnoses of diseases in many parts of the human body, including the skeleton, heart and circulatory system, and the brain. Medical isotopes are subject to radioactive decay and have to be delivered just-in-time through a complex supply chain. However, ageing production facilities and a lack of investment have made the supply of Tc-99m unreliable. This report analyses the use and substitutability of Tc-99m in health care, health-care provider payment mechanisms for scans, and the structure of the supply chain. It concludes that the main reasons for unreliable supply are that production is not economically viable and that the structure of the supply chain prevents producers from charging prices that reflect the full costs of production and supply |
Beschreibung: | 1 Online-Ressource (130 Seiten) 21 x 28cm |
ISBN: | 9789264544703 9789264457188 9789264625099 |
DOI: | 10.1787/9b326195-en |
Internformat
MARC
LEADER | 00000nam a2200000zc 4500 | ||
---|---|---|---|
001 | BV047930811 | ||
003 | DE-604 | ||
007 | cr|uuu---uuuuu | ||
008 | 220413s2019 xx o|||| 00||| eng d | ||
020 | |a 9789264544703 |9 978-92-64-54470-3 | ||
020 | |a 9789264457188 |9 978-92-64-45718-8 | ||
020 | |a 9789264625099 |9 978-92-64-62509-9 | ||
024 | 7 | |a 10.1787/9b326195-en |2 doi | |
035 | |a (ZDB-13-SOC)061329649 | ||
035 | |a (OCoLC)1312708208 | ||
035 | |a (DE-599)BVBBV047930811 | ||
040 | |a DE-604 |b ger |e aacr | ||
041 | 0 | |a eng | |
049 | |a DE-384 |a DE-91 |a DE-473 |a DE-824 |a DE-29 |a DE-739 |a DE-355 |a DE-20 |a DE-1028 |a DE-1049 |a DE-188 |a DE-521 |a DE-861 |a DE-898 |a DE-92 |a DE-573 |a DE-19 | ||
245 | 1 | 0 | |a The Supply of Medical Isotopes |b An Economic Diagnosis and Possible Solutions |c Organisation for Economic Co-operation and Development and Nuclear Energy Agency |
264 | 1 | |a Paris |b OECD Publishing |c 2019 | |
300 | |a 1 Online-Ressource (130 Seiten) |c 21 x 28cm | ||
336 | |b txt |2 rdacontent | ||
337 | |b c |2 rdamedia | ||
338 | |b cr |2 rdacarrier | ||
520 | |a This report explores the main reasons behind the unreliable supply of Technetium-99m (Tc-99m) in health-care systems and policy options to address the issue. Tc-99m is used in 85% of nuclear medicine diagnostic scans performed worldwide - around 30 million patient examinations every year. These scans allow diagnoses of diseases in many parts of the human body, including the skeleton, heart and circulatory system, and the brain. Medical isotopes are subject to radioactive decay and have to be delivered just-in-time through a complex supply chain. However, ageing production facilities and a lack of investment have made the supply of Tc-99m unreliable. This report analyses the use and substitutability of Tc-99m in health care, health-care provider payment mechanisms for scans, and the structure of the supply chain. It concludes that the main reasons for unreliable supply are that production is not economically viable and that the structure of the supply chain prevents producers from charging prices that reflect the full costs of production and supply | ||
650 | 4 | |a Social Issues/Migration/Health | |
650 | 4 | |a Science and Technology | |
650 | 4 | |a Industry and Services | |
710 | 2 | |a Nuclear Energy Agency |4 Herausgebendes Organ |4 isb | |
856 | 4 | 0 | |u https://doi.org/10.1787/9b326195-en |x Verlag |z kostenfrei |3 Volltext |
912 | |a ZDB-13-SOC | ||
943 | 1 | |a oai:aleph.bib-bvb.de:BVB01-033312304 |
Datensatz im Suchindex
_version_ | 1818805995085758464 |
---|---|
adam_text | |
adam_txt | |
any_adam_object | |
any_adam_object_boolean | |
building | Verbundindex |
bvnumber | BV047930811 |
collection | ZDB-13-SOC |
ctrlnum | (ZDB-13-SOC)061329649 (OCoLC)1312708208 (DE-599)BVBBV047930811 |
discipline | Wirtschaftswissenschaften |
discipline_str_mv | Wirtschaftswissenschaften |
doi_str_mv | 10.1787/9b326195-en |
format | Electronic eBook |
fullrecord | <?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>00000nam a2200000zc 4500</leader><controlfield tag="001">BV047930811</controlfield><controlfield tag="003">DE-604</controlfield><controlfield tag="007">cr|uuu---uuuuu</controlfield><controlfield tag="008">220413s2019 xx o|||| 00||| eng d</controlfield><datafield tag="020" ind1=" " ind2=" "><subfield code="a">9789264544703</subfield><subfield code="9">978-92-64-54470-3</subfield></datafield><datafield tag="020" ind1=" " ind2=" "><subfield code="a">9789264457188</subfield><subfield code="9">978-92-64-45718-8</subfield></datafield><datafield tag="020" ind1=" " ind2=" "><subfield code="a">9789264625099</subfield><subfield code="9">978-92-64-62509-9</subfield></datafield><datafield tag="024" ind1="7" ind2=" "><subfield code="a">10.1787/9b326195-en</subfield><subfield code="2">doi</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(ZDB-13-SOC)061329649</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(OCoLC)1312708208</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-599)BVBBV047930811</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-604</subfield><subfield code="b">ger</subfield><subfield code="e">aacr</subfield></datafield><datafield tag="041" ind1="0" ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="049" ind1=" " ind2=" "><subfield code="a">DE-384</subfield><subfield code="a">DE-91</subfield><subfield code="a">DE-473</subfield><subfield code="a">DE-824</subfield><subfield code="a">DE-29</subfield><subfield code="a">DE-739</subfield><subfield code="a">DE-355</subfield><subfield code="a">DE-20</subfield><subfield code="a">DE-1028</subfield><subfield code="a">DE-1049</subfield><subfield code="a">DE-188</subfield><subfield code="a">DE-521</subfield><subfield code="a">DE-861</subfield><subfield code="a">DE-898</subfield><subfield code="a">DE-92</subfield><subfield code="a">DE-573</subfield><subfield code="a">DE-19</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">The Supply of Medical Isotopes</subfield><subfield code="b">An Economic Diagnosis and Possible Solutions</subfield><subfield code="c">Organisation for Economic Co-operation and Development and Nuclear Energy Agency</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="a">Paris</subfield><subfield code="b">OECD Publishing</subfield><subfield code="c">2019</subfield></datafield><datafield tag="300" ind1=" " ind2=" "><subfield code="a">1 Online-Ressource (130 Seiten)</subfield><subfield code="c">21 x 28cm</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="b">txt</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="b">c</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="b">cr</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">This report explores the main reasons behind the unreliable supply of Technetium-99m (Tc-99m) in health-care systems and policy options to address the issue. Tc-99m is used in 85% of nuclear medicine diagnostic scans performed worldwide - around 30 million patient examinations every year. These scans allow diagnoses of diseases in many parts of the human body, including the skeleton, heart and circulatory system, and the brain. Medical isotopes are subject to radioactive decay and have to be delivered just-in-time through a complex supply chain. However, ageing production facilities and a lack of investment have made the supply of Tc-99m unreliable. This report analyses the use and substitutability of Tc-99m in health care, health-care provider payment mechanisms for scans, and the structure of the supply chain. It concludes that the main reasons for unreliable supply are that production is not economically viable and that the structure of the supply chain prevents producers from charging prices that reflect the full costs of production and supply</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Social Issues/Migration/Health</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Science and Technology</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Industry and Services</subfield></datafield><datafield tag="710" ind1="2" ind2=" "><subfield code="a">Nuclear Energy Agency</subfield><subfield code="4">Herausgebendes Organ</subfield><subfield code="4">isb</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">https://doi.org/10.1787/9b326195-en</subfield><subfield code="x">Verlag</subfield><subfield code="z">kostenfrei</subfield><subfield code="3">Volltext</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">ZDB-13-SOC</subfield></datafield><datafield tag="943" ind1="1" ind2=" "><subfield code="a">oai:aleph.bib-bvb.de:BVB01-033312304</subfield></datafield></record></collection> |
id | DE-604.BV047930811 |
illustrated | Not Illustrated |
index_date | 2024-07-03T19:34:56Z |
indexdate | 2024-12-18T19:02:44Z |
institution | BVB |
isbn | 9789264544703 9789264457188 9789264625099 |
language | English |
oai_aleph_id | oai:aleph.bib-bvb.de:BVB01-033312304 |
oclc_num | 1312708208 |
open_access_boolean | 1 |
owner | DE-384 DE-91 DE-BY-TUM DE-473 DE-BY-UBG DE-824 DE-29 DE-739 DE-355 DE-BY-UBR DE-20 DE-1028 DE-1049 DE-188 DE-521 DE-861 DE-898 DE-BY-UBR DE-92 DE-573 DE-19 DE-BY-UBM |
owner_facet | DE-384 DE-91 DE-BY-TUM DE-473 DE-BY-UBG DE-824 DE-29 DE-739 DE-355 DE-BY-UBR DE-20 DE-1028 DE-1049 DE-188 DE-521 DE-861 DE-898 DE-BY-UBR DE-92 DE-573 DE-19 DE-BY-UBM |
physical | 1 Online-Ressource (130 Seiten) 21 x 28cm |
psigel | ZDB-13-SOC |
publishDate | 2019 |
publishDateSearch | 2019 |
publishDateSort | 2019 |
publisher | OECD Publishing |
record_format | marc |
spelling | The Supply of Medical Isotopes An Economic Diagnosis and Possible Solutions Organisation for Economic Co-operation and Development and Nuclear Energy Agency Paris OECD Publishing 2019 1 Online-Ressource (130 Seiten) 21 x 28cm txt rdacontent c rdamedia cr rdacarrier This report explores the main reasons behind the unreliable supply of Technetium-99m (Tc-99m) in health-care systems and policy options to address the issue. Tc-99m is used in 85% of nuclear medicine diagnostic scans performed worldwide - around 30 million patient examinations every year. These scans allow diagnoses of diseases in many parts of the human body, including the skeleton, heart and circulatory system, and the brain. Medical isotopes are subject to radioactive decay and have to be delivered just-in-time through a complex supply chain. However, ageing production facilities and a lack of investment have made the supply of Tc-99m unreliable. This report analyses the use and substitutability of Tc-99m in health care, health-care provider payment mechanisms for scans, and the structure of the supply chain. It concludes that the main reasons for unreliable supply are that production is not economically viable and that the structure of the supply chain prevents producers from charging prices that reflect the full costs of production and supply Social Issues/Migration/Health Science and Technology Industry and Services Nuclear Energy Agency Herausgebendes Organ isb https://doi.org/10.1787/9b326195-en Verlag kostenfrei Volltext |
spellingShingle | The Supply of Medical Isotopes An Economic Diagnosis and Possible Solutions Social Issues/Migration/Health Science and Technology Industry and Services |
title | The Supply of Medical Isotopes An Economic Diagnosis and Possible Solutions |
title_auth | The Supply of Medical Isotopes An Economic Diagnosis and Possible Solutions |
title_exact_search | The Supply of Medical Isotopes An Economic Diagnosis and Possible Solutions |
title_exact_search_txtP | The Supply of Medical Isotopes An Economic Diagnosis and Possible Solutions |
title_full | The Supply of Medical Isotopes An Economic Diagnosis and Possible Solutions Organisation for Economic Co-operation and Development and Nuclear Energy Agency |
title_fullStr | The Supply of Medical Isotopes An Economic Diagnosis and Possible Solutions Organisation for Economic Co-operation and Development and Nuclear Energy Agency |
title_full_unstemmed | The Supply of Medical Isotopes An Economic Diagnosis and Possible Solutions Organisation for Economic Co-operation and Development and Nuclear Energy Agency |
title_short | The Supply of Medical Isotopes |
title_sort | the supply of medical isotopes an economic diagnosis and possible solutions |
title_sub | An Economic Diagnosis and Possible Solutions |
topic | Social Issues/Migration/Health Science and Technology Industry and Services |
topic_facet | Social Issues/Migration/Health Science and Technology Industry and Services |
url | https://doi.org/10.1787/9b326195-en |
work_keys_str_mv | AT nuclearenergyagency thesupplyofmedicalisotopesaneconomicdiagnosisandpossiblesolutions |