Clinical PET:
During the past decade Positron Emission Tomography (PET) has turned from a highly sophisticated tool developed for basic research in neurology and cardiology into an advanced nuclear medicine imaging technique ready for routine use. Along with remarkable technical improvements, an overwhelming numb...
Gespeichert in:
Weitere Verfasser: | , |
---|---|
Format: | Elektronisch E-Book |
Sprache: | English |
Veröffentlicht: |
Dordrecht
Springer Netherlands
1996
|
Schriftenreihe: | Developments in Nuclear Medicine
28 |
Schlagworte: | |
Online-Zugang: | UBR01 Volltext |
Zusammenfassung: | During the past decade Positron Emission Tomography (PET) has turned from a highly sophisticated tool developed for basic research in neurology and cardiology into an advanced nuclear medicine imaging technique ready for routine use. Along with remarkable technical improvements, an overwhelming number of PET studies has been published covering not only scientific but also relevant clinical problems. Due to this rapid development, comprehensive information about the current status of 'clinical' PET is lacking. In this book the applications of PET in neurology, cardiology and oncology are discussed in separate sections. In each section, following an introduction reviewing the present clinical demands, special diagnostic problems and their possible solution by PET are addressed. Results of conventional scintigraphic techniques are also mentioned, and compared with PET. In the last section, technical aspects (e.g. instrumentation, software) are presented, including statements of representatives of leading manufacturers in the field. Clinical PET provides a critical overview of relevant applications of PET for all those who are starting to run a PET facility or are planning to do so. The book is also dedicated to interested clinicians who are willing to utilize the diagnostic potential of PET. |
Beschreibung: | 1 Online-Ressource (XII, 140 p) |
ISBN: | 9789400903098 |
DOI: | 10.1007/978-94-009-0309-8 |
Internformat
MARC
LEADER | 00000nmm a2200000zcb4500 | ||
---|---|---|---|
001 | BV046145665 | ||
003 | DE-604 | ||
005 | 00000000000000.0 | ||
007 | cr|uuu---uuuuu | ||
008 | 190905s1996 |||| o||u| ||||||eng d | ||
020 | |a 9789400903098 |9 978-94-009-0309-8 | ||
024 | 7 | |a 10.1007/978-94-009-0309-8 |2 doi | |
035 | |a (ZDB-2-SME)978-94-009-0309-8 | ||
035 | |a (OCoLC)1119148376 | ||
035 | |a (DE-599)BVBBV046145665 | ||
040 | |a DE-604 |b ger |e aacr | ||
041 | 0 | |a eng | |
049 | |a DE-355 | ||
082 | 0 | |a 616.0757 |2 23 | |
245 | 1 | 0 | |a Clinical PET |c edited by Roland B. Bares, Giovanni Lucignani |
264 | 1 | |a Dordrecht |b Springer Netherlands |c 1996 | |
300 | |a 1 Online-Ressource (XII, 140 p) | ||
336 | |b txt |2 rdacontent | ||
337 | |b c |2 rdamedia | ||
338 | |b cr |2 rdacarrier | ||
490 | 0 | |a Developments in Nuclear Medicine |v 28 | |
520 | |a During the past decade Positron Emission Tomography (PET) has turned from a highly sophisticated tool developed for basic research in neurology and cardiology into an advanced nuclear medicine imaging technique ready for routine use. Along with remarkable technical improvements, an overwhelming number of PET studies has been published covering not only scientific but also relevant clinical problems. Due to this rapid development, comprehensive information about the current status of 'clinical' PET is lacking. In this book the applications of PET in neurology, cardiology and oncology are discussed in separate sections. In each section, following an introduction reviewing the present clinical demands, special diagnostic problems and their possible solution by PET are addressed. Results of conventional scintigraphic techniques are also mentioned, and compared with PET. In the last section, technical aspects (e.g. instrumentation, software) are presented, including statements of representatives of leading manufacturers in the field. Clinical PET provides a critical overview of relevant applications of PET for all those who are starting to run a PET facility or are planning to do so. The book is also dedicated to interested clinicians who are willing to utilize the diagnostic potential of PET. | ||
650 | 4 | |a Imaging / Radiology | |
650 | 4 | |a Nuclear Medicine | |
650 | 4 | |a Radiology, Medical | |
650 | 4 | |a Nuclear medicine | |
650 | 0 | 7 | |a Positronen-Emissions-Tomografie |0 (DE-588)4129799-4 |2 gnd |9 rswk-swf |
655 | 7 | |0 (DE-588)1071861417 |a Konferenzschrift |y 1994 |z Düsseldorf |2 gnd-content | |
689 | 0 | 0 | |a Positronen-Emissions-Tomografie |0 (DE-588)4129799-4 |D s |
689 | 0 | |5 DE-604 | |
700 | 1 | |a Bares, Roland B. |4 edt | |
700 | 1 | |a Lucignani, Giovanni |4 edt | |
776 | 0 | 8 | |i Erscheint auch als |n Druck-Ausgabe |z 9789401066242 |
776 | 0 | 8 | |i Erscheint auch als |n Druck-Ausgabe |z 9789400903104 |
776 | 0 | 8 | |i Erscheint auch als |n Druck-Ausgabe |z 9780792341604 |
856 | 4 | 0 | |u https://doi.org/10.1007/978-94-009-0309-8 |x Verlag |z URL des Erstveröffentlichers |3 Volltext |
912 | |a ZDB-2-SME | ||
940 | 1 | |q ZDB-2-SME_1990/2004 | |
999 | |a oai:aleph.bib-bvb.de:BVB01-031525850 | ||
966 | e | |u https://doi.org/10.1007/978-94-009-0309-8 |l UBR01 |p ZDB-2-SME |q ZDB-2-SME_1990/2004 |x Verlag |3 Volltext |
Datensatz im Suchindex
_version_ | 1804180482606235648 |
---|---|
any_adam_object | |
author2 | Bares, Roland B. Lucignani, Giovanni |
author2_role | edt edt |
author2_variant | r b b rb rbb g l gl |
author_facet | Bares, Roland B. Lucignani, Giovanni |
building | Verbundindex |
bvnumber | BV046145665 |
collection | ZDB-2-SME |
ctrlnum | (ZDB-2-SME)978-94-009-0309-8 (OCoLC)1119148376 (DE-599)BVBBV046145665 |
dewey-full | 616.0757 |
dewey-hundreds | 600 - Technology (Applied sciences) |
dewey-ones | 616 - Diseases |
dewey-raw | 616.0757 |
dewey-search | 616.0757 |
dewey-sort | 3616.0757 |
dewey-tens | 610 - Medicine and health |
discipline | Medizin |
doi_str_mv | 10.1007/978-94-009-0309-8 |
format | Electronic eBook |
fullrecord | <?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>03154nmm a2200505zcb4500</leader><controlfield tag="001">BV046145665</controlfield><controlfield tag="003">DE-604</controlfield><controlfield tag="005">00000000000000.0</controlfield><controlfield tag="007">cr|uuu---uuuuu</controlfield><controlfield tag="008">190905s1996 |||| o||u| ||||||eng d</controlfield><datafield tag="020" ind1=" " ind2=" "><subfield code="a">9789400903098</subfield><subfield code="9">978-94-009-0309-8</subfield></datafield><datafield tag="024" ind1="7" ind2=" "><subfield code="a">10.1007/978-94-009-0309-8</subfield><subfield code="2">doi</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(ZDB-2-SME)978-94-009-0309-8</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(OCoLC)1119148376</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-599)BVBBV046145665</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-604</subfield><subfield code="b">ger</subfield><subfield code="e">aacr</subfield></datafield><datafield tag="041" ind1="0" ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="049" ind1=" " ind2=" "><subfield code="a">DE-355</subfield></datafield><datafield tag="082" ind1="0" ind2=" "><subfield code="a">616.0757</subfield><subfield code="2">23</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">Clinical PET</subfield><subfield code="c">edited by Roland B. Bares, Giovanni Lucignani</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="a">Dordrecht</subfield><subfield code="b">Springer Netherlands</subfield><subfield code="c">1996</subfield></datafield><datafield tag="300" ind1=" " ind2=" "><subfield code="a">1 Online-Ressource (XII, 140 p)</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="b">txt</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="b">c</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="b">cr</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="490" ind1="0" ind2=" "><subfield code="a">Developments in Nuclear Medicine</subfield><subfield code="v">28</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">During the past decade Positron Emission Tomography (PET) has turned from a highly sophisticated tool developed for basic research in neurology and cardiology into an advanced nuclear medicine imaging technique ready for routine use. Along with remarkable technical improvements, an overwhelming number of PET studies has been published covering not only scientific but also relevant clinical problems. Due to this rapid development, comprehensive information about the current status of 'clinical' PET is lacking. In this book the applications of PET in neurology, cardiology and oncology are discussed in separate sections. In each section, following an introduction reviewing the present clinical demands, special diagnostic problems and their possible solution by PET are addressed. Results of conventional scintigraphic techniques are also mentioned, and compared with PET. In the last section, technical aspects (e.g. instrumentation, software) are presented, including statements of representatives of leading manufacturers in the field. Clinical PET provides a critical overview of relevant applications of PET for all those who are starting to run a PET facility or are planning to do so. The book is also dedicated to interested clinicians who are willing to utilize the diagnostic potential of PET.</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Imaging / Radiology</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Nuclear Medicine</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Radiology, Medical</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Nuclear medicine</subfield></datafield><datafield tag="650" ind1="0" ind2="7"><subfield code="a">Positronen-Emissions-Tomografie</subfield><subfield code="0">(DE-588)4129799-4</subfield><subfield code="2">gnd</subfield><subfield code="9">rswk-swf</subfield></datafield><datafield tag="655" ind1=" " ind2="7"><subfield code="0">(DE-588)1071861417</subfield><subfield code="a">Konferenzschrift</subfield><subfield code="y">1994</subfield><subfield code="z">Düsseldorf</subfield><subfield code="2">gnd-content</subfield></datafield><datafield tag="689" ind1="0" ind2="0"><subfield code="a">Positronen-Emissions-Tomografie</subfield><subfield code="0">(DE-588)4129799-4</subfield><subfield code="D">s</subfield></datafield><datafield tag="689" ind1="0" ind2=" "><subfield code="5">DE-604</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Bares, Roland B.</subfield><subfield code="4">edt</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Lucignani, Giovanni</subfield><subfield code="4">edt</subfield></datafield><datafield tag="776" ind1="0" ind2="8"><subfield code="i">Erscheint auch als</subfield><subfield code="n">Druck-Ausgabe</subfield><subfield code="z">9789401066242</subfield></datafield><datafield tag="776" ind1="0" ind2="8"><subfield code="i">Erscheint auch als</subfield><subfield code="n">Druck-Ausgabe</subfield><subfield code="z">9789400903104</subfield></datafield><datafield tag="776" ind1="0" ind2="8"><subfield code="i">Erscheint auch als</subfield><subfield code="n">Druck-Ausgabe</subfield><subfield code="z">9780792341604</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">https://doi.org/10.1007/978-94-009-0309-8</subfield><subfield code="x">Verlag</subfield><subfield code="z">URL des Erstveröffentlichers</subfield><subfield code="3">Volltext</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">ZDB-2-SME</subfield></datafield><datafield tag="940" ind1="1" ind2=" "><subfield code="q">ZDB-2-SME_1990/2004</subfield></datafield><datafield tag="999" ind1=" " ind2=" "><subfield code="a">oai:aleph.bib-bvb.de:BVB01-031525850</subfield></datafield><datafield tag="966" ind1="e" ind2=" "><subfield code="u">https://doi.org/10.1007/978-94-009-0309-8</subfield><subfield code="l">UBR01</subfield><subfield code="p">ZDB-2-SME</subfield><subfield code="q">ZDB-2-SME_1990/2004</subfield><subfield code="x">Verlag</subfield><subfield code="3">Volltext</subfield></datafield></record></collection> |
genre | (DE-588)1071861417 Konferenzschrift 1994 Düsseldorf gnd-content |
genre_facet | Konferenzschrift 1994 Düsseldorf |
id | DE-604.BV046145665 |
illustrated | Not Illustrated |
indexdate | 2024-07-10T08:36:28Z |
institution | BVB |
isbn | 9789400903098 |
language | English |
oai_aleph_id | oai:aleph.bib-bvb.de:BVB01-031525850 |
oclc_num | 1119148376 |
open_access_boolean | |
owner | DE-355 DE-BY-UBR |
owner_facet | DE-355 DE-BY-UBR |
physical | 1 Online-Ressource (XII, 140 p) |
psigel | ZDB-2-SME ZDB-2-SME_1990/2004 ZDB-2-SME ZDB-2-SME_1990/2004 |
publishDate | 1996 |
publishDateSearch | 1996 |
publishDateSort | 1996 |
publisher | Springer Netherlands |
record_format | marc |
series2 | Developments in Nuclear Medicine |
spelling | Clinical PET edited by Roland B. Bares, Giovanni Lucignani Dordrecht Springer Netherlands 1996 1 Online-Ressource (XII, 140 p) txt rdacontent c rdamedia cr rdacarrier Developments in Nuclear Medicine 28 During the past decade Positron Emission Tomography (PET) has turned from a highly sophisticated tool developed for basic research in neurology and cardiology into an advanced nuclear medicine imaging technique ready for routine use. Along with remarkable technical improvements, an overwhelming number of PET studies has been published covering not only scientific but also relevant clinical problems. Due to this rapid development, comprehensive information about the current status of 'clinical' PET is lacking. In this book the applications of PET in neurology, cardiology and oncology are discussed in separate sections. In each section, following an introduction reviewing the present clinical demands, special diagnostic problems and their possible solution by PET are addressed. Results of conventional scintigraphic techniques are also mentioned, and compared with PET. In the last section, technical aspects (e.g. instrumentation, software) are presented, including statements of representatives of leading manufacturers in the field. Clinical PET provides a critical overview of relevant applications of PET for all those who are starting to run a PET facility or are planning to do so. The book is also dedicated to interested clinicians who are willing to utilize the diagnostic potential of PET. Imaging / Radiology Nuclear Medicine Radiology, Medical Nuclear medicine Positronen-Emissions-Tomografie (DE-588)4129799-4 gnd rswk-swf (DE-588)1071861417 Konferenzschrift 1994 Düsseldorf gnd-content Positronen-Emissions-Tomografie (DE-588)4129799-4 s DE-604 Bares, Roland B. edt Lucignani, Giovanni edt Erscheint auch als Druck-Ausgabe 9789401066242 Erscheint auch als Druck-Ausgabe 9789400903104 Erscheint auch als Druck-Ausgabe 9780792341604 https://doi.org/10.1007/978-94-009-0309-8 Verlag URL des Erstveröffentlichers Volltext |
spellingShingle | Clinical PET Imaging / Radiology Nuclear Medicine Radiology, Medical Nuclear medicine Positronen-Emissions-Tomografie (DE-588)4129799-4 gnd |
subject_GND | (DE-588)4129799-4 (DE-588)1071861417 |
title | Clinical PET |
title_auth | Clinical PET |
title_exact_search | Clinical PET |
title_full | Clinical PET edited by Roland B. Bares, Giovanni Lucignani |
title_fullStr | Clinical PET edited by Roland B. Bares, Giovanni Lucignani |
title_full_unstemmed | Clinical PET edited by Roland B. Bares, Giovanni Lucignani |
title_short | Clinical PET |
title_sort | clinical pet |
topic | Imaging / Radiology Nuclear Medicine Radiology, Medical Nuclear medicine Positronen-Emissions-Tomografie (DE-588)4129799-4 gnd |
topic_facet | Imaging / Radiology Nuclear Medicine Radiology, Medical Nuclear medicine Positronen-Emissions-Tomografie Konferenzschrift 1994 Düsseldorf |
url | https://doi.org/10.1007/978-94-009-0309-8 |
work_keys_str_mv | AT baresrolandb clinicalpet AT lucignanigiovanni clinicalpet |