Interfaces in Total Hip Arthroplasty:
This book incorporates the experience of numerous experts who explore contemporary opinion of how best to rationalise and optimise the interfaces at total hip replacement to provide the most favourable and durable results. The survival of a total hip replacement depends principally on the enduring i...
Gespeichert in:
Weitere Verfasser: | |
---|---|
Format: | Elektronisch E-Book |
Sprache: | English |
Veröffentlicht: |
London
Springer London
2000
|
Schlagworte: | |
Online-Zugang: | UBR01 Volltext |
Zusammenfassung: | This book incorporates the experience of numerous experts who explore contemporary opinion of how best to rationalise and optimise the interfaces at total hip replacement to provide the most favourable and durable results. The survival of a total hip replacement depends principally on the enduring integrity of the fixation interfaces and of the articular interface. The design of the stem and the material properties of cement largely determine the state of the component-cement inter face, while the bone-cement interface is significantly influenced by both mechanical and biological factors. The surface finish and shape of cementless implants are designed to preserve the integrity of biological fixation (osseo-integration) at the bone-component interface. Once again, both mechanical and biological factors have to be considered, while bioactive coatings accelerate bone ongrowth. Metal-on-polyethylene is the most widely used articular interface. However, it has been suggested that wear of polyethylene is one of the major factors contributing to failure of total hip replacements. The increasing prevalence of total hip replacement in younger patients has stimulated the investigation of alternative, more durable couples -including ceramic-polyethylene, ceramic-ceramic and metal-on-metal. Modularity provides greater intra-operative flexibility, but each new modular interface introduces new mechanisms of failure. These need to be anticipated and appropriate measures taken to avoid them. Hopefully this book will provide a better understanding of the factors that contribute to stable interfaces and long-term survival of total hip arthroplasty |
Beschreibung: | 1 Online-Ressource (XII, 168 p) |
ISBN: | 9781447104773 |
DOI: | 10.1007/978-1-4471-0477-3 |
Internformat
MARC
LEADER | 00000nmm a2200000zc 4500 | ||
---|---|---|---|
001 | BV046145371 | ||
003 | DE-604 | ||
005 | 00000000000000.0 | ||
007 | cr|uuu---uuuuu | ||
008 | 190905s2000 |||| o||u| ||||||eng d | ||
020 | |a 9781447104773 |9 978-1-4471-0477-3 | ||
024 | 7 | |a 10.1007/978-1-4471-0477-3 |2 doi | |
035 | |a (ZDB-2-SME)978-1-4471-0477-3 | ||
035 | |a (OCoLC)1119002792 | ||
035 | |a (DE-599)BVBBV046145371 | ||
040 | |a DE-604 |b ger |e aacr | ||
041 | 0 | |a eng | |
049 | |a DE-355 | ||
082 | 0 | |a 616.7 |2 23 | |
084 | |a YK 3550 |0 (DE-625)153735:13129 |2 rvk | ||
245 | 1 | 0 | |a Interfaces in Total Hip Arthroplasty |c edited by Ian D. Learmonth |
264 | 1 | |a London |b Springer London |c 2000 | |
300 | |a 1 Online-Ressource (XII, 168 p) | ||
336 | |b txt |2 rdacontent | ||
337 | |b c |2 rdamedia | ||
338 | |b cr |2 rdacarrier | ||
520 | |a This book incorporates the experience of numerous experts who explore contemporary opinion of how best to rationalise and optimise the interfaces at total hip replacement to provide the most favourable and durable results. The survival of a total hip replacement depends principally on the enduring integrity of the fixation interfaces and of the articular interface. The design of the stem and the material properties of cement largely determine the state of the component-cement inter face, while the bone-cement interface is significantly influenced by both mechanical and biological factors. The surface finish and shape of cementless implants are designed to preserve the integrity of biological fixation (osseo-integration) at the bone-component interface. Once again, both mechanical and biological factors have to be considered, while bioactive coatings accelerate bone ongrowth. Metal-on-polyethylene is the most widely used articular interface. However, it has been suggested that wear of polyethylene is one of the major factors contributing to failure of total hip replacements. The increasing prevalence of total hip replacement in younger patients has stimulated the investigation of alternative, more durable couples -including ceramic-polyethylene, ceramic-ceramic and metal-on-metal. Modularity provides greater intra-operative flexibility, but each new modular interface introduces new mechanisms of failure. These need to be anticipated and appropriate measures taken to avoid them. Hopefully this book will provide a better understanding of the factors that contribute to stable interfaces and long-term survival of total hip arthroplasty | ||
650 | 4 | |a Orthopedics | |
650 | 4 | |a Imaging / Radiology | |
650 | 4 | |a Rheumatology | |
650 | 4 | |a Orthopedics | |
650 | 4 | |a Radiology, Medical | |
650 | 4 | |a Rheumatology | |
650 | 0 | 7 | |a Hüftgelenk |0 (DE-588)4026025-2 |2 gnd |9 rswk-swf |
650 | 0 | 7 | |a Arthroplastik |0 (DE-588)4204008-5 |2 gnd |9 rswk-swf |
655 | 7 | |0 (DE-588)1071861417 |a Konferenzschrift |2 gnd-content | |
655 | 7 | |0 (DE-588)4143413-4 |a Aufsatzsammlung |2 gnd-content | |
689 | 0 | 0 | |a Hüftgelenk |0 (DE-588)4026025-2 |D s |
689 | 0 | 1 | |a Arthroplastik |0 (DE-588)4204008-5 |D s |
689 | 0 | |5 DE-604 | |
700 | 1 | |a Learmonth, Ian D. |4 edt | |
776 | 0 | 8 | |i Erscheint auch als |n Druck-Ausgabe |z 9781852332051 |
776 | 0 | 8 | |i Erscheint auch als |n Druck-Ausgabe |z 9781447111504 |
776 | 0 | 8 | |i Erscheint auch als |n Druck-Ausgabe |z 9781447104780 |
856 | 4 | 0 | |u https://doi.org/10.1007/978-1-4471-0477-3 |x Verlag |z URL des Erstveröffentlichers |3 Volltext |
912 | |a ZDB-2-SME | ||
940 | 1 | |q ZDB-2-SME_1990/2004 | |
999 | |a oai:aleph.bib-bvb.de:BVB01-031525556 | ||
966 | e | |u https://doi.org/10.1007/978-1-4471-0477-3 |l UBR01 |p ZDB-2-SME |q ZDB-2-SME_1990/2004 |x Verlag |3 Volltext |
Datensatz im Suchindex
_version_ | 1804180481955069952 |
---|---|
any_adam_object | |
author2 | Learmonth, Ian D. |
author2_role | edt |
author2_variant | i d l id idl |
author_facet | Learmonth, Ian D. |
building | Verbundindex |
bvnumber | BV046145371 |
classification_rvk | YK 3550 |
collection | ZDB-2-SME |
ctrlnum | (ZDB-2-SME)978-1-4471-0477-3 (OCoLC)1119002792 (DE-599)BVBBV046145371 |
dewey-full | 616.7 |
dewey-hundreds | 600 - Technology (Applied sciences) |
dewey-ones | 616 - Diseases |
dewey-raw | 616.7 |
dewey-search | 616.7 |
dewey-sort | 3616.7 |
dewey-tens | 610 - Medicine and health |
discipline | Medizin |
doi_str_mv | 10.1007/978-1-4471-0477-3 |
format | Electronic eBook |
fullrecord | <?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>03626nmm a2200553zc 4500</leader><controlfield tag="001">BV046145371</controlfield><controlfield tag="003">DE-604</controlfield><controlfield tag="005">00000000000000.0</controlfield><controlfield tag="007">cr|uuu---uuuuu</controlfield><controlfield tag="008">190905s2000 |||| o||u| ||||||eng d</controlfield><datafield tag="020" ind1=" " ind2=" "><subfield code="a">9781447104773</subfield><subfield code="9">978-1-4471-0477-3</subfield></datafield><datafield tag="024" ind1="7" ind2=" "><subfield code="a">10.1007/978-1-4471-0477-3</subfield><subfield code="2">doi</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(ZDB-2-SME)978-1-4471-0477-3</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(OCoLC)1119002792</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-599)BVBBV046145371</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-604</subfield><subfield code="b">ger</subfield><subfield code="e">aacr</subfield></datafield><datafield tag="041" ind1="0" ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="049" ind1=" " ind2=" "><subfield code="a">DE-355</subfield></datafield><datafield tag="082" ind1="0" ind2=" "><subfield code="a">616.7</subfield><subfield code="2">23</subfield></datafield><datafield tag="084" ind1=" " ind2=" "><subfield code="a">YK 3550</subfield><subfield code="0">(DE-625)153735:13129</subfield><subfield code="2">rvk</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">Interfaces in Total Hip Arthroplasty</subfield><subfield code="c">edited by Ian D. Learmonth</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="a">London</subfield><subfield code="b">Springer London</subfield><subfield code="c">2000</subfield></datafield><datafield tag="300" ind1=" " ind2=" "><subfield code="a">1 Online-Ressource (XII, 168 p)</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="b">txt</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="b">c</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="b">cr</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">This book incorporates the experience of numerous experts who explore contemporary opinion of how best to rationalise and optimise the interfaces at total hip replacement to provide the most favourable and durable results. The survival of a total hip replacement depends principally on the enduring integrity of the fixation interfaces and of the articular interface. The design of the stem and the material properties of cement largely determine the state of the component-cement inter face, while the bone-cement interface is significantly influenced by both mechanical and biological factors. The surface finish and shape of cementless implants are designed to preserve the integrity of biological fixation (osseo-integration) at the bone-component interface. Once again, both mechanical and biological factors have to be considered, while bioactive coatings accelerate bone ongrowth. Metal-on-polyethylene is the most widely used articular interface. However, it has been suggested that wear of polyethylene is one of the major factors contributing to failure of total hip replacements. The increasing prevalence of total hip replacement in younger patients has stimulated the investigation of alternative, more durable couples -including ceramic-polyethylene, ceramic-ceramic and metal-on-metal. Modularity provides greater intra-operative flexibility, but each new modular interface introduces new mechanisms of failure. These need to be anticipated and appropriate measures taken to avoid them. Hopefully this book will provide a better understanding of the factors that contribute to stable interfaces and long-term survival of total hip arthroplasty</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Orthopedics</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Imaging / Radiology</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Rheumatology</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Orthopedics</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Radiology, Medical</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Rheumatology</subfield></datafield><datafield tag="650" ind1="0" ind2="7"><subfield code="a">Hüftgelenk</subfield><subfield code="0">(DE-588)4026025-2</subfield><subfield code="2">gnd</subfield><subfield code="9">rswk-swf</subfield></datafield><datafield tag="650" ind1="0" ind2="7"><subfield code="a">Arthroplastik</subfield><subfield code="0">(DE-588)4204008-5</subfield><subfield code="2">gnd</subfield><subfield code="9">rswk-swf</subfield></datafield><datafield tag="655" ind1=" " ind2="7"><subfield code="0">(DE-588)1071861417</subfield><subfield code="a">Konferenzschrift</subfield><subfield code="2">gnd-content</subfield></datafield><datafield tag="655" ind1=" " ind2="7"><subfield code="0">(DE-588)4143413-4</subfield><subfield code="a">Aufsatzsammlung</subfield><subfield code="2">gnd-content</subfield></datafield><datafield tag="689" ind1="0" ind2="0"><subfield code="a">Hüftgelenk</subfield><subfield code="0">(DE-588)4026025-2</subfield><subfield code="D">s</subfield></datafield><datafield tag="689" ind1="0" ind2="1"><subfield code="a">Arthroplastik</subfield><subfield code="0">(DE-588)4204008-5</subfield><subfield code="D">s</subfield></datafield><datafield tag="689" ind1="0" ind2=" "><subfield code="5">DE-604</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Learmonth, Ian D.</subfield><subfield code="4">edt</subfield></datafield><datafield tag="776" ind1="0" ind2="8"><subfield code="i">Erscheint auch als</subfield><subfield code="n">Druck-Ausgabe</subfield><subfield code="z">9781852332051</subfield></datafield><datafield tag="776" ind1="0" ind2="8"><subfield code="i">Erscheint auch als</subfield><subfield code="n">Druck-Ausgabe</subfield><subfield code="z">9781447111504</subfield></datafield><datafield tag="776" ind1="0" ind2="8"><subfield code="i">Erscheint auch als</subfield><subfield code="n">Druck-Ausgabe</subfield><subfield code="z">9781447104780</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">https://doi.org/10.1007/978-1-4471-0477-3</subfield><subfield code="x">Verlag</subfield><subfield code="z">URL des Erstveröffentlichers</subfield><subfield code="3">Volltext</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">ZDB-2-SME</subfield></datafield><datafield tag="940" ind1="1" ind2=" "><subfield code="q">ZDB-2-SME_1990/2004</subfield></datafield><datafield tag="999" ind1=" " ind2=" "><subfield code="a">oai:aleph.bib-bvb.de:BVB01-031525556</subfield></datafield><datafield tag="966" ind1="e" ind2=" "><subfield code="u">https://doi.org/10.1007/978-1-4471-0477-3</subfield><subfield code="l">UBR01</subfield><subfield code="p">ZDB-2-SME</subfield><subfield code="q">ZDB-2-SME_1990/2004</subfield><subfield code="x">Verlag</subfield><subfield code="3">Volltext</subfield></datafield></record></collection> |
genre | (DE-588)1071861417 Konferenzschrift gnd-content (DE-588)4143413-4 Aufsatzsammlung gnd-content |
genre_facet | Konferenzschrift Aufsatzsammlung |
id | DE-604.BV046145371 |
illustrated | Not Illustrated |
indexdate | 2024-07-10T08:36:27Z |
institution | BVB |
isbn | 9781447104773 |
language | English |
oai_aleph_id | oai:aleph.bib-bvb.de:BVB01-031525556 |
oclc_num | 1119002792 |
open_access_boolean | |
owner | DE-355 DE-BY-UBR |
owner_facet | DE-355 DE-BY-UBR |
physical | 1 Online-Ressource (XII, 168 p) |
psigel | ZDB-2-SME ZDB-2-SME_1990/2004 ZDB-2-SME ZDB-2-SME_1990/2004 |
publishDate | 2000 |
publishDateSearch | 2000 |
publishDateSort | 2000 |
publisher | Springer London |
record_format | marc |
spelling | Interfaces in Total Hip Arthroplasty edited by Ian D. Learmonth London Springer London 2000 1 Online-Ressource (XII, 168 p) txt rdacontent c rdamedia cr rdacarrier This book incorporates the experience of numerous experts who explore contemporary opinion of how best to rationalise and optimise the interfaces at total hip replacement to provide the most favourable and durable results. The survival of a total hip replacement depends principally on the enduring integrity of the fixation interfaces and of the articular interface. The design of the stem and the material properties of cement largely determine the state of the component-cement inter face, while the bone-cement interface is significantly influenced by both mechanical and biological factors. The surface finish and shape of cementless implants are designed to preserve the integrity of biological fixation (osseo-integration) at the bone-component interface. Once again, both mechanical and biological factors have to be considered, while bioactive coatings accelerate bone ongrowth. Metal-on-polyethylene is the most widely used articular interface. However, it has been suggested that wear of polyethylene is one of the major factors contributing to failure of total hip replacements. The increasing prevalence of total hip replacement in younger patients has stimulated the investigation of alternative, more durable couples -including ceramic-polyethylene, ceramic-ceramic and metal-on-metal. Modularity provides greater intra-operative flexibility, but each new modular interface introduces new mechanisms of failure. These need to be anticipated and appropriate measures taken to avoid them. Hopefully this book will provide a better understanding of the factors that contribute to stable interfaces and long-term survival of total hip arthroplasty Orthopedics Imaging / Radiology Rheumatology Radiology, Medical Hüftgelenk (DE-588)4026025-2 gnd rswk-swf Arthroplastik (DE-588)4204008-5 gnd rswk-swf (DE-588)1071861417 Konferenzschrift gnd-content (DE-588)4143413-4 Aufsatzsammlung gnd-content Hüftgelenk (DE-588)4026025-2 s Arthroplastik (DE-588)4204008-5 s DE-604 Learmonth, Ian D. edt Erscheint auch als Druck-Ausgabe 9781852332051 Erscheint auch als Druck-Ausgabe 9781447111504 Erscheint auch als Druck-Ausgabe 9781447104780 https://doi.org/10.1007/978-1-4471-0477-3 Verlag URL des Erstveröffentlichers Volltext |
spellingShingle | Interfaces in Total Hip Arthroplasty Orthopedics Imaging / Radiology Rheumatology Radiology, Medical Hüftgelenk (DE-588)4026025-2 gnd Arthroplastik (DE-588)4204008-5 gnd |
subject_GND | (DE-588)4026025-2 (DE-588)4204008-5 (DE-588)1071861417 (DE-588)4143413-4 |
title | Interfaces in Total Hip Arthroplasty |
title_auth | Interfaces in Total Hip Arthroplasty |
title_exact_search | Interfaces in Total Hip Arthroplasty |
title_full | Interfaces in Total Hip Arthroplasty edited by Ian D. Learmonth |
title_fullStr | Interfaces in Total Hip Arthroplasty edited by Ian D. Learmonth |
title_full_unstemmed | Interfaces in Total Hip Arthroplasty edited by Ian D. Learmonth |
title_short | Interfaces in Total Hip Arthroplasty |
title_sort | interfaces in total hip arthroplasty |
topic | Orthopedics Imaging / Radiology Rheumatology Radiology, Medical Hüftgelenk (DE-588)4026025-2 gnd Arthroplastik (DE-588)4204008-5 gnd |
topic_facet | Orthopedics Imaging / Radiology Rheumatology Radiology, Medical Hüftgelenk Arthroplastik Konferenzschrift Aufsatzsammlung |
url | https://doi.org/10.1007/978-1-4471-0477-3 |
work_keys_str_mv | AT learmonthiand interfacesintotalhiparthroplasty |