Beschreibung: | The book starts with a detailed description of ICP-MS, including quadruple-based, sector-based and time-of-flight instruments. Instrumentation from existing manufacturers is described and compared to show their similarities and differences. Also, a review of the ICP-MS literature is carried out to outline both the strengths and limitations of the technique, whatever its brand, as well as what it can currently accomplish in terms of applications. Then, the book demonstrates how these limitations can be reduced and/or eliminated by combining various techniques with ICP-MS. Great detail is provided on each technique so that the reader can get a good understanding of it before carrying on to the instrumental requirements for its hyphenation to ICP-MS, and the resulting impact on the operation of the hyphenated instrument. Since this book is concerned with the ICP side only, which is fairly similar in all the instruments from the different manufacturers, the information should be useful to all ICP-MS users. The features and limitations of each technique are thoroughly discussed and illustrated with a review of the ICP-MS literature. Approaches which could be used but have not yet been tried with ICP-MS are also suggested. This is particularly true of flow injection techniques which are extremely flexible and have been used extensively in atomic spectroscopy and spectrophotometry. Many of the features of the technique have not yet been combined to ICP-MS, and one purpose of the book will be to point out potentially beneficial combinations Includes bibliographical references and index |
Beschreibung: | xviii, 575 pages |
ISBN: | 9780444899514 0444899510 |
Internformat
MARC
LEADER | 00000nmm a2200000zcb4500 | ||
---|---|---|---|
001 | BV044382379 | ||
003 | DE-604 | ||
005 | 00000000000000.0 | ||
007 | cr|uuu---uuuuu | ||
008 | 170630s2000 |||| o||u| ||||||eng d | ||
020 | |a 9780444899514 |9 978-0-444-89951-4 | ||
020 | |a 0444899510 |9 0-444-89951-0 | ||
035 | |a (ZDB-33-ESD)ocn772908173 | ||
035 | |a (OCoLC)772908173 | ||
035 | |a (DE-599)BVBBV044382379 | ||
040 | |a DE-604 |b ger |e aacr | ||
041 | 0 | |a eng | |
049 | |a DE-1046 | ||
082 | 0 | |a 543.0873 |2 22 | |
245 | 1 | 0 | |a Discrete sample introduction techniques for inductively coupled plasma mass spectrometry |c edited by Diane Beauchemin [and five others] |
264 | 1 | |a Amsterdam |b Elsevier |c 2000 | |
300 | |a xviii, 575 pages | ||
336 | |b txt |2 rdacontent | ||
337 | |b c |2 rdamedia | ||
338 | |b cr |2 rdacarrier | ||
490 | 0 | |a Comprehensive analytical chemistry |v v. 34 | |
500 | |a The book starts with a detailed description of ICP-MS, including quadruple-based, sector-based and time-of-flight instruments. Instrumentation from existing manufacturers is described and compared to show their similarities and differences. Also, a review of the ICP-MS literature is carried out to outline both the strengths and limitations of the technique, whatever its brand, as well as what it can currently accomplish in terms of applications. Then, the book demonstrates how these limitations can be reduced and/or eliminated by combining various techniques with ICP-MS. Great detail is provided on each technique so that the reader can get a good understanding of it before carrying on to the instrumental requirements for its hyphenation to ICP-MS, and the resulting impact on the operation of the hyphenated instrument. Since this book is concerned with the ICP side only, which is fairly similar in all the instruments from the different manufacturers, the information should be useful to all ICP-MS users. The features and limitations of each technique are thoroughly discussed and illustrated with a review of the ICP-MS literature. Approaches which could be used but have not yet been tried with ICP-MS are also suggested. This is particularly true of flow injection techniques which are extremely flexible and have been used extensively in atomic spectroscopy and spectrophotometry. Many of the features of the technique have not yet been combined to ICP-MS, and one purpose of the book will be to point out potentially beneficial combinations | ||
500 | |a Includes bibliographical references and index | ||
650 | 7 | |a Inductively coupled plasma mass spectrometry |2 fast | |
650 | 7 | |a Spectroscopie de masse à plasma induit par haute fréquence |2 ram | |
650 | 4 | |a Inductively coupled plasma mass spectrometry | |
700 | 1 | |a Beauchemin, Diane |e Sonstige |4 oth | |
856 | 4 | 0 | |u http://www.sciencedirect.com/science/handbooks/0166526X/34 |x Verlag |z URL des Erstveröffentlichers |3 Volltext |
912 | |a ZDB-33-ESD | ||
999 | |a oai:aleph.bib-bvb.de:BVB01-029784600 | ||
966 | e | |u http://www.sciencedirect.com/science/handbooks/0166526X/34 |l FAW01 |p ZDB-33-ESD |q FAW_PDA_ESD |x Verlag |3 Volltext |
Datensatz im Suchindex
_version_ | 1804177646646460416 |
---|---|
any_adam_object | |
building | Verbundindex |
bvnumber | BV044382379 |
collection | ZDB-33-ESD |
ctrlnum | (ZDB-33-ESD)ocn772908173 (OCoLC)772908173 (DE-599)BVBBV044382379 |
dewey-full | 543.0873 |
dewey-hundreds | 500 - Natural sciences and mathematics |
dewey-ones | 543 - Analytical chemistry |
dewey-raw | 543.0873 |
dewey-search | 543.0873 |
dewey-sort | 3543.0873 |
dewey-tens | 540 - Chemistry and allied sciences |
discipline | Chemie / Pharmazie |
format | Electronic eBook |
fullrecord | <?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>03089nmm a2200397zcb4500</leader><controlfield tag="001">BV044382379</controlfield><controlfield tag="003">DE-604</controlfield><controlfield tag="005">00000000000000.0</controlfield><controlfield tag="007">cr|uuu---uuuuu</controlfield><controlfield tag="008">170630s2000 |||| o||u| ||||||eng d</controlfield><datafield tag="020" ind1=" " ind2=" "><subfield code="a">9780444899514</subfield><subfield code="9">978-0-444-89951-4</subfield></datafield><datafield tag="020" ind1=" " ind2=" "><subfield code="a">0444899510</subfield><subfield code="9">0-444-89951-0</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(ZDB-33-ESD)ocn772908173</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(OCoLC)772908173</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-599)BVBBV044382379</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-604</subfield><subfield code="b">ger</subfield><subfield code="e">aacr</subfield></datafield><datafield tag="041" ind1="0" ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="049" ind1=" " ind2=" "><subfield code="a">DE-1046</subfield></datafield><datafield tag="082" ind1="0" ind2=" "><subfield code="a">543.0873</subfield><subfield code="2">22</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">Discrete sample introduction techniques for inductively coupled plasma mass spectrometry</subfield><subfield code="c">edited by Diane Beauchemin [and five others]</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="a">Amsterdam</subfield><subfield code="b">Elsevier</subfield><subfield code="c">2000</subfield></datafield><datafield tag="300" ind1=" " ind2=" "><subfield code="a">xviii, 575 pages</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="b">txt</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="b">c</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="b">cr</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="490" ind1="0" ind2=" "><subfield code="a">Comprehensive analytical chemistry</subfield><subfield code="v">v. 34</subfield></datafield><datafield tag="500" ind1=" " ind2=" "><subfield code="a">The book starts with a detailed description of ICP-MS, including quadruple-based, sector-based and time-of-flight instruments. Instrumentation from existing manufacturers is described and compared to show their similarities and differences. Also, a review of the ICP-MS literature is carried out to outline both the strengths and limitations of the technique, whatever its brand, as well as what it can currently accomplish in terms of applications. Then, the book demonstrates how these limitations can be reduced and/or eliminated by combining various techniques with ICP-MS. Great detail is provided on each technique so that the reader can get a good understanding of it before carrying on to the instrumental requirements for its hyphenation to ICP-MS, and the resulting impact on the operation of the hyphenated instrument. Since this book is concerned with the ICP side only, which is fairly similar in all the instruments from the different manufacturers, the information should be useful to all ICP-MS users. The features and limitations of each technique are thoroughly discussed and illustrated with a review of the ICP-MS literature. Approaches which could be used but have not yet been tried with ICP-MS are also suggested. This is particularly true of flow injection techniques which are extremely flexible and have been used extensively in atomic spectroscopy and spectrophotometry. Many of the features of the technique have not yet been combined to ICP-MS, and one purpose of the book will be to point out potentially beneficial combinations</subfield></datafield><datafield tag="500" ind1=" " ind2=" "><subfield code="a">Includes bibliographical references and index</subfield></datafield><datafield tag="650" ind1=" " ind2="7"><subfield code="a">Inductively coupled plasma mass spectrometry</subfield><subfield code="2">fast</subfield></datafield><datafield tag="650" ind1=" " ind2="7"><subfield code="a">Spectroscopie de masse à plasma induit par haute fréquence</subfield><subfield code="2">ram</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Inductively coupled plasma mass spectrometry</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Beauchemin, Diane</subfield><subfield code="e">Sonstige</subfield><subfield code="4">oth</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">http://www.sciencedirect.com/science/handbooks/0166526X/34</subfield><subfield code="x">Verlag</subfield><subfield code="z">URL des Erstveröffentlichers</subfield><subfield code="3">Volltext</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">ZDB-33-ESD</subfield></datafield><datafield tag="999" ind1=" " ind2=" "><subfield code="a">oai:aleph.bib-bvb.de:BVB01-029784600</subfield></datafield><datafield tag="966" ind1="e" ind2=" "><subfield code="u">http://www.sciencedirect.com/science/handbooks/0166526X/34</subfield><subfield code="l">FAW01</subfield><subfield code="p">ZDB-33-ESD</subfield><subfield code="q">FAW_PDA_ESD</subfield><subfield code="x">Verlag</subfield><subfield code="3">Volltext</subfield></datafield></record></collection> |
id | DE-604.BV044382379 |
illustrated | Not Illustrated |
indexdate | 2024-07-10T07:51:23Z |
institution | BVB |
isbn | 9780444899514 0444899510 |
language | English |
oai_aleph_id | oai:aleph.bib-bvb.de:BVB01-029784600 |
oclc_num | 772908173 |
open_access_boolean | |
owner | DE-1046 |
owner_facet | DE-1046 |
physical | xviii, 575 pages |
psigel | ZDB-33-ESD ZDB-33-ESD FAW_PDA_ESD |
publishDate | 2000 |
publishDateSearch | 2000 |
publishDateSort | 2000 |
publisher | Elsevier |
record_format | marc |
series2 | Comprehensive analytical chemistry |
spelling | Discrete sample introduction techniques for inductively coupled plasma mass spectrometry edited by Diane Beauchemin [and five others] Amsterdam Elsevier 2000 xviii, 575 pages txt rdacontent c rdamedia cr rdacarrier Comprehensive analytical chemistry v. 34 The book starts with a detailed description of ICP-MS, including quadruple-based, sector-based and time-of-flight instruments. Instrumentation from existing manufacturers is described and compared to show their similarities and differences. Also, a review of the ICP-MS literature is carried out to outline both the strengths and limitations of the technique, whatever its brand, as well as what it can currently accomplish in terms of applications. Then, the book demonstrates how these limitations can be reduced and/or eliminated by combining various techniques with ICP-MS. Great detail is provided on each technique so that the reader can get a good understanding of it before carrying on to the instrumental requirements for its hyphenation to ICP-MS, and the resulting impact on the operation of the hyphenated instrument. Since this book is concerned with the ICP side only, which is fairly similar in all the instruments from the different manufacturers, the information should be useful to all ICP-MS users. The features and limitations of each technique are thoroughly discussed and illustrated with a review of the ICP-MS literature. Approaches which could be used but have not yet been tried with ICP-MS are also suggested. This is particularly true of flow injection techniques which are extremely flexible and have been used extensively in atomic spectroscopy and spectrophotometry. Many of the features of the technique have not yet been combined to ICP-MS, and one purpose of the book will be to point out potentially beneficial combinations Includes bibliographical references and index Inductively coupled plasma mass spectrometry fast Spectroscopie de masse à plasma induit par haute fréquence ram Inductively coupled plasma mass spectrometry Beauchemin, Diane Sonstige oth http://www.sciencedirect.com/science/handbooks/0166526X/34 Verlag URL des Erstveröffentlichers Volltext |
spellingShingle | Discrete sample introduction techniques for inductively coupled plasma mass spectrometry Inductively coupled plasma mass spectrometry fast Spectroscopie de masse à plasma induit par haute fréquence ram Inductively coupled plasma mass spectrometry |
title | Discrete sample introduction techniques for inductively coupled plasma mass spectrometry |
title_auth | Discrete sample introduction techniques for inductively coupled plasma mass spectrometry |
title_exact_search | Discrete sample introduction techniques for inductively coupled plasma mass spectrometry |
title_full | Discrete sample introduction techniques for inductively coupled plasma mass spectrometry edited by Diane Beauchemin [and five others] |
title_fullStr | Discrete sample introduction techniques for inductively coupled plasma mass spectrometry edited by Diane Beauchemin [and five others] |
title_full_unstemmed | Discrete sample introduction techniques for inductively coupled plasma mass spectrometry edited by Diane Beauchemin [and five others] |
title_short | Discrete sample introduction techniques for inductively coupled plasma mass spectrometry |
title_sort | discrete sample introduction techniques for inductively coupled plasma mass spectrometry |
topic | Inductively coupled plasma mass spectrometry fast Spectroscopie de masse à plasma induit par haute fréquence ram Inductively coupled plasma mass spectrometry |
topic_facet | Inductively coupled plasma mass spectrometry Spectroscopie de masse à plasma induit par haute fréquence |
url | http://www.sciencedirect.com/science/handbooks/0166526X/34 |
work_keys_str_mv | AT beauchemindiane discretesampleintroductiontechniquesforinductivelycoupledplasmamassspectrometry |