Voltage source converter HVDC connection of offshore wind farms and the application of batteries:
Gespeichert in:
1. Verfasser: | |
---|---|
Format: | Abschlussarbeit Buch |
Sprache: | English |
Veröffentlicht: |
Aachen
Shaker
2009
|
Schlagworte: | |
Online-Zugang: | Inhaltsverzeichnis |
Beschreibung: | III, 165 S. Ill., graph. Darst. |
ISBN: | 9783832278687 |
Internformat
MARC
LEADER | 00000nam a2200000 c 4500 | ||
---|---|---|---|
001 | BV035640043 | ||
003 | DE-604 | ||
005 | 20090807 | ||
007 | t | ||
008 | 090722s2009 gw ad|| m||| 00||| eng d | ||
015 | |a 09,H07,2449 |2 dnb | ||
016 | 7 | |a 992480779 |2 DE-101 | |
020 | |a 9783832278687 |c kart. : EUR 48.80 |9 978-3-8322-7868-7 | ||
035 | |a (OCoLC)916483369 | ||
035 | |a (DE-599)DNB992480779 | ||
040 | |a DE-604 |b ger |e rakddb | ||
041 | 0 | |a eng | |
044 | |a gw |c XA-DE | ||
049 | |a DE-634 |a DE-83 | ||
082 | 0 | |a 621.312136 |2 22/ger | |
084 | |a ZN 8555 |0 (DE-625)157634: |2 rvk | ||
084 | |a 620 |2 sdnb | ||
100 | 1 | |a Spahić, Ervin |d 1972- |e Verfasser |0 (DE-588)137292783 |4 aut | |
245 | 1 | 0 | |a Voltage source converter HVDC connection of offshore wind farms and the application of batteries |c Ervin Spahić |
264 | 1 | |a Aachen |b Shaker |c 2009 | |
300 | |a III, 165 S. |b Ill., graph. Darst. | ||
336 | |b txt |2 rdacontent | ||
337 | |b n |2 rdamedia | ||
338 | |b nc |2 rdacarrier | ||
502 | |a Zugl.: Darmstadt, Techn. Univ., Diss., 2008 | ||
650 | 0 | 7 | |a Spannungswandler |0 (DE-588)4182091-5 |2 gnd |9 rswk-swf |
650 | 0 | 7 | |a Netzstabilität |g Elektrische Energietechnik |0 (DE-588)4415875-0 |2 gnd |9 rswk-swf |
650 | 0 | 7 | |a Hochspannungsgleichstromübertragung |0 (DE-588)4620681-4 |2 gnd |9 rswk-swf |
650 | 0 | 7 | |a Offshorebauwerk |0 (DE-588)4128556-6 |2 gnd |9 rswk-swf |
650 | 0 | 7 | |a Natrium-Schwefel-Akkumulator |0 (DE-588)4171277-8 |2 gnd |9 rswk-swf |
650 | 0 | 7 | |a Windpark |0 (DE-588)4543294-6 |2 gnd |9 rswk-swf |
655 | 7 | |0 (DE-588)4113937-9 |a Hochschulschrift |2 gnd-content | |
689 | 0 | 0 | |a Windpark |0 (DE-588)4543294-6 |D s |
689 | 0 | 1 | |a Offshorebauwerk |0 (DE-588)4128556-6 |D s |
689 | 0 | 2 | |a Hochspannungsgleichstromübertragung |0 (DE-588)4620681-4 |D s |
689 | 0 | 3 | |a Spannungswandler |0 (DE-588)4182091-5 |D s |
689 | 0 | 4 | |a Natrium-Schwefel-Akkumulator |0 (DE-588)4171277-8 |D s |
689 | 0 | 5 | |a Netzstabilität |g Elektrische Energietechnik |0 (DE-588)4415875-0 |D s |
689 | 0 | |5 DE-604 | |
856 | 4 | 2 | |m DNB Datenaustausch |q application/pdf |u http://bvbr.bib-bvb.de:8991/F?func=service&doc_library=BVB01&local_base=BVB01&doc_number=017694848&sequence=000001&line_number=0001&func_code=DB_RECORDS&service_type=MEDIA |3 Inhaltsverzeichnis |
999 | |a oai:aleph.bib-bvb.de:BVB01-017694848 |
Datensatz im Suchindex
_version_ | 1804139320462802944 |
---|---|
adam_text | CONTENTS 1 PREFACE 1 1.1 BACKGROUND 1 1.2 MOTIVATION AND MAIN
CONTRIBUTIONS 3 1.3 OVERVIEW OF RELATED RESEARCH 4 1.4 THESIS OUTLINE 5
2 WIND POWER 7 2.1 WIND IN GENERAL 7 2.2 POWER FLUCTUATIONS 9 2.2.1 WIND
SPEED AND FLUCTUATIONS 11 2.2.2 WIND FARM SIZE AND SHAPE 12 2.2.3 WIND
DIRECTION 14 2.2.4 WAKE EFFECT 16 2.2.5 SUMMARY OF WIND POWER
FLUCTUATIONS 17 2.3 WIND TURBINE SYSTEMS 17 2.3.1 INDUCTION GENERATOR 19
2.3.2 SYNCHRONOUS GENERATOR 20 2.3.3 DOUBLY FED INDUCTION GENERATOR
(DFIG) 21 3 RELIABILITY ANALYSIS 23 3.1 BASIC PRINCIPLES 23 3.2
RELIABILITY CALCULATIONS 25 3.2.1 RESULTS FOR AN OFFSHORE WIND FARM 29
3.2.2 WIND FARM CONNECTED TO ONE POWER SYSTEM 31 4 TRANSMISSION
POSSIBILITIES 35 4.1 HVAC TRANSMISSION 35 4.2 CLASSICAL HVDC (LCC HVDC)
36 4.3 VOLTAGE SOURCE CONVERTER HVDC (VSC HVDC) 37 4.4 COMBINATION OF
DIFFERENT TECHNOLOGIES 39 4.5 TRANSMISSION TECHNOLOGY COMPARISON 39
BIBLIOGRAFISCHE INFORMATIONEN HTTP://D-NB.INFO/992480779 DIGITALISIERT
DURCH APPENDIX 147 II CONTENTS 5 VSC HVDC 43 5.1 BASIC PRINCIPLES 43 5.2
CONVERTER OPERATION AND PWM PRINCIPLE 47 5.3 CONTROL OF VSC HVDC 51 5.4
LOSSES AND HARMONICS 56 5.5 OPERATION OF VSC HVDC 58 5.6 VSC HVDC RESUME
67 6 BATTERY 69 6.1 STORAGE POSSIBILITIES OF WIND POWER 69 6.2
PRINCIPLES OF WIND FARM - BATTERY OPERATION 74 6.2.1 MODELLING AND
SIMULATION 76 6.2.2 ELECTRICAL MODEL OF BATTERY 80 6.3 ECONOMICAL
ANALYSIS OF BATTERY APPLICATION 82 6.3.1 INVESTMENT COSTS OF NAS BATTERY
82 6.3.2 MARKET ELECTRICITY PRICE 83 6.3.3 FEED-IN TARIFFS - GERMAN CASE
85 6.3.4 RESULTS 88 7 STABILITY ASSESSMENT OF WIND FARM, VSC HVDC,
BATTERY AND SYSTEM 95 7.1 STABILITY OF VSC HVDC 95 7.1.1 SMALL SIGNAL
DISTURBANCE 95 7.1.2 LARGE SIGNAL DISTURBANCE 112 7.2 VSC HVDC IN A TEST
POWER SYSTEM 119 7.2.1 NINE BUS TEST SYSTEM 119 7.2.2 DISTURBANCE IN THE
SYSTEM - BUSBAR B8 120 7.2.3 DISTURBANCE AT THE PCC 122 7.2.4
DISTURBANCE AT WIND FARM SIDE 123 7.2.5 WIND FLUCTUATIONS 125 7.3
BATTERY WITH A TEST SYSTEM 127 7.3.1 BASE CASE 127 7.3.2 CONTROLLABLE
LOADS 128 7.3.3 BATTERY BACKUP 131 7.4 LARGE WIND POWER FLUCTUATIONS AND
BATTERY APPLICATION 133 8 CONCLUSIONS AND OUTLOOK 137 BIBLIOGRAPHY 141 G
ZUSAMMENFASSUNG UND AUSBLICK IN DEUTSCH 163 CONTENTS III A LIST OF
SYMBOLS AND ABBREVIATIONS 147 B MATHEMATICAL MODEL OF DFIG 152 C VSC
HVDC CABLE 158 D ECONOMIC COMPARISON OF HVAC AND VSC HVDC SOLUTIONS 159
E VSC HVDC PROJECTS 160 F PUBLICATIONS 161
|
any_adam_object | 1 |
author | Spahić, Ervin 1972- |
author_GND | (DE-588)137292783 |
author_facet | Spahić, Ervin 1972- |
author_role | aut |
author_sort | Spahić, Ervin 1972- |
author_variant | e s es |
building | Verbundindex |
bvnumber | BV035640043 |
classification_rvk | ZN 8555 |
ctrlnum | (OCoLC)916483369 (DE-599)DNB992480779 |
dewey-full | 621.312136 |
dewey-hundreds | 600 - Technology (Applied sciences) |
dewey-ones | 621 - Applied physics |
dewey-raw | 621.312136 |
dewey-search | 621.312136 |
dewey-sort | 3621.312136 |
dewey-tens | 620 - Engineering and allied operations |
discipline | Maschinenbau / Maschinenwesen Elektrotechnik / Elektronik / Nachrichtentechnik |
format | Thesis Book |
fullrecord | <?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>02245nam a2200517 c 4500</leader><controlfield tag="001">BV035640043</controlfield><controlfield tag="003">DE-604</controlfield><controlfield tag="005">20090807 </controlfield><controlfield tag="007">t</controlfield><controlfield tag="008">090722s2009 gw ad|| m||| 00||| eng d</controlfield><datafield tag="015" ind1=" " ind2=" "><subfield code="a">09,H07,2449</subfield><subfield code="2">dnb</subfield></datafield><datafield tag="016" ind1="7" ind2=" "><subfield code="a">992480779</subfield><subfield code="2">DE-101</subfield></datafield><datafield tag="020" ind1=" " ind2=" "><subfield code="a">9783832278687</subfield><subfield code="c">kart. : EUR 48.80</subfield><subfield code="9">978-3-8322-7868-7</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(OCoLC)916483369</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-599)DNB992480779</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-604</subfield><subfield code="b">ger</subfield><subfield code="e">rakddb</subfield></datafield><datafield tag="041" ind1="0" ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="044" ind1=" " ind2=" "><subfield code="a">gw</subfield><subfield code="c">XA-DE</subfield></datafield><datafield tag="049" ind1=" " ind2=" "><subfield code="a">DE-634</subfield><subfield code="a">DE-83</subfield></datafield><datafield tag="082" ind1="0" ind2=" "><subfield code="a">621.312136</subfield><subfield code="2">22/ger</subfield></datafield><datafield tag="084" ind1=" " ind2=" "><subfield code="a">ZN 8555</subfield><subfield code="0">(DE-625)157634:</subfield><subfield code="2">rvk</subfield></datafield><datafield tag="084" ind1=" " ind2=" "><subfield code="a">620</subfield><subfield code="2">sdnb</subfield></datafield><datafield tag="100" ind1="1" ind2=" "><subfield code="a">Spahić, Ervin</subfield><subfield code="d">1972-</subfield><subfield code="e">Verfasser</subfield><subfield code="0">(DE-588)137292783</subfield><subfield code="4">aut</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">Voltage source converter HVDC connection of offshore wind farms and the application of batteries</subfield><subfield code="c">Ervin Spahić</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="a">Aachen</subfield><subfield code="b">Shaker</subfield><subfield code="c">2009</subfield></datafield><datafield tag="300" ind1=" " ind2=" "><subfield code="a">III, 165 S.</subfield><subfield code="b">Ill., graph. Darst.</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="b">txt</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="b">n</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="b">nc</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="502" ind1=" " ind2=" "><subfield code="a">Zugl.: Darmstadt, Techn. Univ., Diss., 2008</subfield></datafield><datafield tag="650" ind1="0" ind2="7"><subfield code="a">Spannungswandler</subfield><subfield code="0">(DE-588)4182091-5</subfield><subfield code="2">gnd</subfield><subfield code="9">rswk-swf</subfield></datafield><datafield tag="650" ind1="0" ind2="7"><subfield code="a">Netzstabilität</subfield><subfield code="g">Elektrische Energietechnik</subfield><subfield code="0">(DE-588)4415875-0</subfield><subfield code="2">gnd</subfield><subfield code="9">rswk-swf</subfield></datafield><datafield tag="650" ind1="0" ind2="7"><subfield code="a">Hochspannungsgleichstromübertragung</subfield><subfield code="0">(DE-588)4620681-4</subfield><subfield code="2">gnd</subfield><subfield code="9">rswk-swf</subfield></datafield><datafield tag="650" ind1="0" ind2="7"><subfield code="a">Offshorebauwerk</subfield><subfield code="0">(DE-588)4128556-6</subfield><subfield code="2">gnd</subfield><subfield code="9">rswk-swf</subfield></datafield><datafield tag="650" ind1="0" ind2="7"><subfield code="a">Natrium-Schwefel-Akkumulator</subfield><subfield code="0">(DE-588)4171277-8</subfield><subfield code="2">gnd</subfield><subfield code="9">rswk-swf</subfield></datafield><datafield tag="650" ind1="0" ind2="7"><subfield code="a">Windpark</subfield><subfield code="0">(DE-588)4543294-6</subfield><subfield code="2">gnd</subfield><subfield code="9">rswk-swf</subfield></datafield><datafield tag="655" ind1=" " ind2="7"><subfield code="0">(DE-588)4113937-9</subfield><subfield code="a">Hochschulschrift</subfield><subfield code="2">gnd-content</subfield></datafield><datafield tag="689" ind1="0" ind2="0"><subfield code="a">Windpark</subfield><subfield code="0">(DE-588)4543294-6</subfield><subfield code="D">s</subfield></datafield><datafield tag="689" ind1="0" ind2="1"><subfield code="a">Offshorebauwerk</subfield><subfield code="0">(DE-588)4128556-6</subfield><subfield code="D">s</subfield></datafield><datafield tag="689" ind1="0" ind2="2"><subfield code="a">Hochspannungsgleichstromübertragung</subfield><subfield code="0">(DE-588)4620681-4</subfield><subfield code="D">s</subfield></datafield><datafield tag="689" ind1="0" ind2="3"><subfield code="a">Spannungswandler</subfield><subfield code="0">(DE-588)4182091-5</subfield><subfield code="D">s</subfield></datafield><datafield tag="689" ind1="0" ind2="4"><subfield code="a">Natrium-Schwefel-Akkumulator</subfield><subfield code="0">(DE-588)4171277-8</subfield><subfield code="D">s</subfield></datafield><datafield tag="689" ind1="0" ind2="5"><subfield code="a">Netzstabilität</subfield><subfield code="g">Elektrische Energietechnik</subfield><subfield code="0">(DE-588)4415875-0</subfield><subfield code="D">s</subfield></datafield><datafield tag="689" ind1="0" ind2=" "><subfield code="5">DE-604</subfield></datafield><datafield tag="856" ind1="4" ind2="2"><subfield code="m">DNB Datenaustausch</subfield><subfield code="q">application/pdf</subfield><subfield code="u">http://bvbr.bib-bvb.de:8991/F?func=service&doc_library=BVB01&local_base=BVB01&doc_number=017694848&sequence=000001&line_number=0001&func_code=DB_RECORDS&service_type=MEDIA</subfield><subfield code="3">Inhaltsverzeichnis</subfield></datafield><datafield tag="999" ind1=" " ind2=" "><subfield code="a">oai:aleph.bib-bvb.de:BVB01-017694848</subfield></datafield></record></collection> |
genre | (DE-588)4113937-9 Hochschulschrift gnd-content |
genre_facet | Hochschulschrift |
id | DE-604.BV035640043 |
illustrated | Illustrated |
indexdate | 2024-07-09T21:42:13Z |
institution | BVB |
isbn | 9783832278687 |
language | English |
oai_aleph_id | oai:aleph.bib-bvb.de:BVB01-017694848 |
oclc_num | 916483369 |
open_access_boolean | |
owner | DE-634 DE-83 |
owner_facet | DE-634 DE-83 |
physical | III, 165 S. Ill., graph. Darst. |
publishDate | 2009 |
publishDateSearch | 2009 |
publishDateSort | 2009 |
publisher | Shaker |
record_format | marc |
spelling | Spahić, Ervin 1972- Verfasser (DE-588)137292783 aut Voltage source converter HVDC connection of offshore wind farms and the application of batteries Ervin Spahić Aachen Shaker 2009 III, 165 S. Ill., graph. Darst. txt rdacontent n rdamedia nc rdacarrier Zugl.: Darmstadt, Techn. Univ., Diss., 2008 Spannungswandler (DE-588)4182091-5 gnd rswk-swf Netzstabilität Elektrische Energietechnik (DE-588)4415875-0 gnd rswk-swf Hochspannungsgleichstromübertragung (DE-588)4620681-4 gnd rswk-swf Offshorebauwerk (DE-588)4128556-6 gnd rswk-swf Natrium-Schwefel-Akkumulator (DE-588)4171277-8 gnd rswk-swf Windpark (DE-588)4543294-6 gnd rswk-swf (DE-588)4113937-9 Hochschulschrift gnd-content Windpark (DE-588)4543294-6 s Offshorebauwerk (DE-588)4128556-6 s Hochspannungsgleichstromübertragung (DE-588)4620681-4 s Spannungswandler (DE-588)4182091-5 s Natrium-Schwefel-Akkumulator (DE-588)4171277-8 s Netzstabilität Elektrische Energietechnik (DE-588)4415875-0 s DE-604 DNB Datenaustausch application/pdf http://bvbr.bib-bvb.de:8991/F?func=service&doc_library=BVB01&local_base=BVB01&doc_number=017694848&sequence=000001&line_number=0001&func_code=DB_RECORDS&service_type=MEDIA Inhaltsverzeichnis |
spellingShingle | Spahić, Ervin 1972- Voltage source converter HVDC connection of offshore wind farms and the application of batteries Spannungswandler (DE-588)4182091-5 gnd Netzstabilität Elektrische Energietechnik (DE-588)4415875-0 gnd Hochspannungsgleichstromübertragung (DE-588)4620681-4 gnd Offshorebauwerk (DE-588)4128556-6 gnd Natrium-Schwefel-Akkumulator (DE-588)4171277-8 gnd Windpark (DE-588)4543294-6 gnd |
subject_GND | (DE-588)4182091-5 (DE-588)4415875-0 (DE-588)4620681-4 (DE-588)4128556-6 (DE-588)4171277-8 (DE-588)4543294-6 (DE-588)4113937-9 |
title | Voltage source converter HVDC connection of offshore wind farms and the application of batteries |
title_auth | Voltage source converter HVDC connection of offshore wind farms and the application of batteries |
title_exact_search | Voltage source converter HVDC connection of offshore wind farms and the application of batteries |
title_full | Voltage source converter HVDC connection of offshore wind farms and the application of batteries Ervin Spahić |
title_fullStr | Voltage source converter HVDC connection of offshore wind farms and the application of batteries Ervin Spahić |
title_full_unstemmed | Voltage source converter HVDC connection of offshore wind farms and the application of batteries Ervin Spahić |
title_short | Voltage source converter HVDC connection of offshore wind farms and the application of batteries |
title_sort | voltage source converter hvdc connection of offshore wind farms and the application of batteries |
topic | Spannungswandler (DE-588)4182091-5 gnd Netzstabilität Elektrische Energietechnik (DE-588)4415875-0 gnd Hochspannungsgleichstromübertragung (DE-588)4620681-4 gnd Offshorebauwerk (DE-588)4128556-6 gnd Natrium-Schwefel-Akkumulator (DE-588)4171277-8 gnd Windpark (DE-588)4543294-6 gnd |
topic_facet | Spannungswandler Netzstabilität Elektrische Energietechnik Hochspannungsgleichstromübertragung Offshorebauwerk Natrium-Schwefel-Akkumulator Windpark Hochschulschrift |
url | http://bvbr.bib-bvb.de:8991/F?func=service&doc_library=BVB01&local_base=BVB01&doc_number=017694848&sequence=000001&line_number=0001&func_code=DB_RECORDS&service_type=MEDIA |
work_keys_str_mv | AT spahicervin voltagesourceconverterhvdcconnectionofoffshorewindfarmsandtheapplicationofbatteries |