Dorsale atlantoaxiale Dreipunkt-Stabilisierung: Vergleich intraoperativer Parameter zwischen offener und perkutaner Methode
Gespeichert in:
1. Verfasser: | |
---|---|
Format: | Buch |
Sprache: | German |
Veröffentlicht: |
2006
|
Schlagworte: | |
Online-Zugang: | Inhaltsverzeichnis |
Beschreibung: | Ulm, Univ., Diss., 2007 |
Beschreibung: | 46 Bl. Ill. 30 cm |
Internformat
MARC
LEADER | 00000nam a2200000 c 4500 | ||
---|---|---|---|
001 | BV022933745 | ||
003 | DE-604 | ||
005 | 20071122 | ||
007 | t | ||
008 | 071023s2006 gw a||| m||| 00||| ger d | ||
015 | |a 07,H11,1651 |2 dnb | ||
016 | 7 | |a 985407166 |2 DE-101 | |
035 | |a (OCoLC)184992574 | ||
035 | |a (DE-599)DNB985407166 | ||
040 | |a DE-604 |b ger |e rakddb | ||
041 | 0 | |a ger | |
044 | |a gw |c XA-DE | ||
049 | |a DE-355 | ||
082 | 0 | |a 617.5 |2 22/ger | |
084 | |a 610 |2 sdnb | ||
100 | 1 | |a Gleichsner, Franziska |d 1976- |e Verfasser |0 (DE-588)133295745 |4 aut | |
245 | 1 | 0 | |a Dorsale atlantoaxiale Dreipunkt-Stabilisierung |b Vergleich intraoperativer Parameter zwischen offener und perkutaner Methode |c Franziska Gleichsner |
264 | 1 | |c 2006 | |
300 | |a 46 Bl. |b Ill. |c 30 cm | ||
336 | |b txt |2 rdacontent | ||
337 | |b n |2 rdamedia | ||
338 | |b nc |2 rdacarrier | ||
500 | |a Ulm, Univ., Diss., 2007 | ||
655 | 7 | |0 (DE-588)4113937-9 |a Hochschulschrift |2 gnd-content | |
856 | 4 | 2 | |m HBZ Datenaustausch |q application/pdf |u http://bvbr.bib-bvb.de:8991/F?func=service&doc_library=BVB01&local_base=BVB01&doc_number=016138531&sequence=000002&line_number=0001&func_code=DB_RECORDS&service_type=MEDIA |3 Inhaltsverzeichnis |
999 | |a oai:aleph.bib-bvb.de:BVB01-016138531 |
Datensatz im Suchindex
_version_ | 1804137166788362240 |
---|---|
adam_text | Inhaltsverzeichnis 4
Inhaltsverzeichnis
Abkiirzungsverzeichnis 6
1 Einleitung 7
1.1 Einfuhrung 7
1.2 Entwicklung von Implantaten und Techniken zur atlantoaxialen Stabilisierung 8
2 Material und Methode 15
2.1 Patientengut. 15
2.2 Patientendaten 15
2.3 Definition der zu untersuchenden Parameter 16
2.4 Zwei Operationstechniken im Vergleich: Offene dorsale transartikulare Verschraubung
nach Magerl in Kombination mit einer Gallie Fusion versus perkutane dorsale
transartikulare Verschraubung in Kombination mit einer Atlasklammer 17
2.4.1 Anasthesie und Lagerung 17
2.4.2 Offene dorsale transartikulare Verschraubung nach Magerl in Kombination mit einer
Gallie Fusion 20
2.4.2.1 Implantate und Instrumentarium 20
2.4.2.2 Operationstechnik der offenen Methode 20
2.4.3 Perkutane dorsale atlantoaxiale Instrumentierung in Kombination mit der Atlasklammer 22
2.4.3.1 Implantate und Istrumentarium 22
2.4.3.2 Operationstechnik der perkutanen Methode 22
2.4.3.3 Technik der Schraubenplatzierung 26
2.4.3.4 Postoperative Behandlung 26
2.4.4 Statistische Methoden 26
3 Ergebnisse 29
3.1 Geschlechtsverteilung und Durchschnittsalter. 29
3.2 Operationsindikationen 29
3.3 Pra und postoperative Laborwerte 30
3.4 Operationszeit 31
3.5 Blutverlust wa hrend der Operation, nach der Operation und Gesamtblutverlust 31
3.6 Schraubenlage 32
3.7 Statistische Ergebnisse 33
3.8 Komplikationen 34
Inhaltsverzeichnis 5
4 Diskussion 35
5 Zusammenfassung 38
6 Literaturverzeichnis 41
Anhang 44
Danksagung 45
Lebenslauf 46
|
adam_txt |
Inhaltsverzeichnis 4
Inhaltsverzeichnis
Abkiirzungsverzeichnis 6
1 Einleitung 7
1.1 Einfuhrung 7
1.2 Entwicklung von Implantaten und Techniken zur atlantoaxialen Stabilisierung 8
2 Material und Methode 15
2.1 Patientengut. 15
2.2 Patientendaten 15
2.3 Definition der zu untersuchenden Parameter 16
2.4 Zwei Operationstechniken im Vergleich: Offene dorsale transartikulare Verschraubung
nach Magerl in Kombination mit einer Gallie Fusion versus perkutane dorsale
transartikulare Verschraubung in Kombination mit einer Atlasklammer 17
2.4.1 Anasthesie und Lagerung 17
2.4.2 Offene dorsale transartikulare Verschraubung nach Magerl in Kombination mit einer
Gallie Fusion 20
2.4.2.1 Implantate und Instrumentarium 20
2.4.2.2 Operationstechnik der offenen Methode 20
2.4.3 Perkutane dorsale atlantoaxiale Instrumentierung in Kombination mit der Atlasklammer 22
2.4.3.1 Implantate und Istrumentarium 22
2.4.3.2 Operationstechnik der perkutanen Methode 22
2.4.3.3 Technik der Schraubenplatzierung 26
2.4.3.4 Postoperative Behandlung 26
2.4.4 Statistische Methoden 26
3 Ergebnisse 29
3.1 Geschlechtsverteilung und Durchschnittsalter. 29
3.2 Operationsindikationen 29
3.3 Pra und postoperative Laborwerte 30
3.4 Operationszeit 31
3.5 Blutverlust wa'hrend der Operation, nach der Operation und Gesamtblutverlust 31
3.6 Schraubenlage 32
3.7 Statistische Ergebnisse 33
3.8 Komplikationen 34
Inhaltsverzeichnis 5
4 Diskussion 35
5 Zusammenfassung 38
6 Literaturverzeichnis 41
Anhang 44
Danksagung 45
Lebenslauf 46 |
any_adam_object | 1 |
any_adam_object_boolean | 1 |
author | Gleichsner, Franziska 1976- |
author_GND | (DE-588)133295745 |
author_facet | Gleichsner, Franziska 1976- |
author_role | aut |
author_sort | Gleichsner, Franziska 1976- |
author_variant | f g fg |
building | Verbundindex |
bvnumber | BV022933745 |
ctrlnum | (OCoLC)184992574 (DE-599)DNB985407166 |
dewey-full | 617.5 |
dewey-hundreds | 600 - Technology (Applied sciences) |
dewey-ones | 617 - Surgery & related medical specialties |
dewey-raw | 617.5 |
dewey-search | 617.5 |
dewey-sort | 3617.5 |
dewey-tens | 610 - Medicine and health |
discipline | Medizin |
discipline_str_mv | Medizin |
format | Book |
fullrecord | <?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01256nam a2200337 c 4500</leader><controlfield tag="001">BV022933745</controlfield><controlfield tag="003">DE-604</controlfield><controlfield tag="005">20071122 </controlfield><controlfield tag="007">t</controlfield><controlfield tag="008">071023s2006 gw a||| m||| 00||| ger d</controlfield><datafield tag="015" ind1=" " ind2=" "><subfield code="a">07,H11,1651</subfield><subfield code="2">dnb</subfield></datafield><datafield tag="016" ind1="7" ind2=" "><subfield code="a">985407166</subfield><subfield code="2">DE-101</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(OCoLC)184992574</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-599)DNB985407166</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-604</subfield><subfield code="b">ger</subfield><subfield code="e">rakddb</subfield></datafield><datafield tag="041" ind1="0" ind2=" "><subfield code="a">ger</subfield></datafield><datafield tag="044" ind1=" " ind2=" "><subfield code="a">gw</subfield><subfield code="c">XA-DE</subfield></datafield><datafield tag="049" ind1=" " ind2=" "><subfield code="a">DE-355</subfield></datafield><datafield tag="082" ind1="0" ind2=" "><subfield code="a">617.5</subfield><subfield code="2">22/ger</subfield></datafield><datafield tag="084" ind1=" " ind2=" "><subfield code="a">610</subfield><subfield code="2">sdnb</subfield></datafield><datafield tag="100" ind1="1" ind2=" "><subfield code="a">Gleichsner, Franziska</subfield><subfield code="d">1976-</subfield><subfield code="e">Verfasser</subfield><subfield code="0">(DE-588)133295745</subfield><subfield code="4">aut</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">Dorsale atlantoaxiale Dreipunkt-Stabilisierung</subfield><subfield code="b">Vergleich intraoperativer Parameter zwischen offener und perkutaner Methode</subfield><subfield code="c">Franziska Gleichsner</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">2006</subfield></datafield><datafield tag="300" ind1=" " ind2=" "><subfield code="a">46 Bl.</subfield><subfield code="b">Ill.</subfield><subfield code="c">30 cm</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="b">txt</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="b">n</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="b">nc</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="500" ind1=" " ind2=" "><subfield code="a">Ulm, Univ., Diss., 2007</subfield></datafield><datafield tag="655" ind1=" " ind2="7"><subfield code="0">(DE-588)4113937-9</subfield><subfield code="a">Hochschulschrift</subfield><subfield code="2">gnd-content</subfield></datafield><datafield tag="856" ind1="4" ind2="2"><subfield code="m">HBZ Datenaustausch</subfield><subfield code="q">application/pdf</subfield><subfield code="u">http://bvbr.bib-bvb.de:8991/F?func=service&doc_library=BVB01&local_base=BVB01&doc_number=016138531&sequence=000002&line_number=0001&func_code=DB_RECORDS&service_type=MEDIA</subfield><subfield code="3">Inhaltsverzeichnis</subfield></datafield><datafield tag="999" ind1=" " ind2=" "><subfield code="a">oai:aleph.bib-bvb.de:BVB01-016138531</subfield></datafield></record></collection> |
genre | (DE-588)4113937-9 Hochschulschrift gnd-content |
genre_facet | Hochschulschrift |
id | DE-604.BV022933745 |
illustrated | Illustrated |
index_date | 2024-07-02T18:55:28Z |
indexdate | 2024-07-09T21:07:59Z |
institution | BVB |
language | German |
oai_aleph_id | oai:aleph.bib-bvb.de:BVB01-016138531 |
oclc_num | 184992574 |
open_access_boolean | |
owner | DE-355 DE-BY-UBR |
owner_facet | DE-355 DE-BY-UBR |
physical | 46 Bl. Ill. 30 cm |
publishDate | 2006 |
publishDateSearch | 2006 |
publishDateSort | 2006 |
record_format | marc |
spelling | Gleichsner, Franziska 1976- Verfasser (DE-588)133295745 aut Dorsale atlantoaxiale Dreipunkt-Stabilisierung Vergleich intraoperativer Parameter zwischen offener und perkutaner Methode Franziska Gleichsner 2006 46 Bl. Ill. 30 cm txt rdacontent n rdamedia nc rdacarrier Ulm, Univ., Diss., 2007 (DE-588)4113937-9 Hochschulschrift gnd-content HBZ Datenaustausch application/pdf http://bvbr.bib-bvb.de:8991/F?func=service&doc_library=BVB01&local_base=BVB01&doc_number=016138531&sequence=000002&line_number=0001&func_code=DB_RECORDS&service_type=MEDIA Inhaltsverzeichnis |
spellingShingle | Gleichsner, Franziska 1976- Dorsale atlantoaxiale Dreipunkt-Stabilisierung Vergleich intraoperativer Parameter zwischen offener und perkutaner Methode |
subject_GND | (DE-588)4113937-9 |
title | Dorsale atlantoaxiale Dreipunkt-Stabilisierung Vergleich intraoperativer Parameter zwischen offener und perkutaner Methode |
title_auth | Dorsale atlantoaxiale Dreipunkt-Stabilisierung Vergleich intraoperativer Parameter zwischen offener und perkutaner Methode |
title_exact_search | Dorsale atlantoaxiale Dreipunkt-Stabilisierung Vergleich intraoperativer Parameter zwischen offener und perkutaner Methode |
title_exact_search_txtP | Dorsale atlantoaxiale Dreipunkt-Stabilisierung Vergleich intraoperativer Parameter zwischen offener und perkutaner Methode |
title_full | Dorsale atlantoaxiale Dreipunkt-Stabilisierung Vergleich intraoperativer Parameter zwischen offener und perkutaner Methode Franziska Gleichsner |
title_fullStr | Dorsale atlantoaxiale Dreipunkt-Stabilisierung Vergleich intraoperativer Parameter zwischen offener und perkutaner Methode Franziska Gleichsner |
title_full_unstemmed | Dorsale atlantoaxiale Dreipunkt-Stabilisierung Vergleich intraoperativer Parameter zwischen offener und perkutaner Methode Franziska Gleichsner |
title_short | Dorsale atlantoaxiale Dreipunkt-Stabilisierung |
title_sort | dorsale atlantoaxiale dreipunkt stabilisierung vergleich intraoperativer parameter zwischen offener und perkutaner methode |
title_sub | Vergleich intraoperativer Parameter zwischen offener und perkutaner Methode |
topic_facet | Hochschulschrift |
url | http://bvbr.bib-bvb.de:8991/F?func=service&doc_library=BVB01&local_base=BVB01&doc_number=016138531&sequence=000002&line_number=0001&func_code=DB_RECORDS&service_type=MEDIA |
work_keys_str_mv | AT gleichsnerfranziska dorsaleatlantoaxialedreipunktstabilisierungvergleichintraoperativerparameterzwischenoffenerundperkutanermethode |