Therapie der In-Stent-Stenose: Vergleich von Excimerlaserangioplastie, Rotablation und konventioneller Ballonangioplastie
Gespeichert in:
1. Verfasser: | |
---|---|
Format: | Buch |
Sprache: | German |
Veröffentlicht: |
2000
|
Schlagworte: | |
Online-Zugang: | Inhaltsverzeichnis |
Beschreibung: | Leipzig, Univ., Diss., 2000 |
Beschreibung: | 106 Bl. Ill., graph. Darst. : 30 cm |
Internformat
MARC
LEADER | 00000nam a2200000 c 4500 | ||
---|---|---|---|
001 | BV013620607 | ||
003 | DE-604 | ||
007 | t | ||
008 | 010228s2000 gw ad|| m||| 00||| ger d | ||
016 | 7 | |a 960648631 |2 DE-101 | |
035 | |a (OCoLC)48717138 | ||
035 | |a (DE-599)BVBBV013620607 | ||
040 | |a DE-604 |b ger |e rakddb | ||
041 | 0 | |a ger | |
044 | |a gw |c DE | ||
049 | |a DE-355 | ||
084 | |a 610 |2 sdnb | ||
100 | 1 | |a Ambrosch, Heiko |d 1965- |e Verfasser |0 (DE-588)122641493 |4 aut | |
245 | 1 | 0 | |a Therapie der In-Stent-Stenose |b Vergleich von Excimerlaserangioplastie, Rotablation und konventioneller Ballonangioplastie |c eingereicht von Heiko Ambrosch |
264 | 1 | |c 2000 | |
300 | |a 106 Bl. |b Ill., graph. Darst. : 30 cm | ||
336 | |b txt |2 rdacontent | ||
337 | |b n |2 rdamedia | ||
338 | |b nc |2 rdacarrier | ||
500 | |a Leipzig, Univ., Diss., 2000 | ||
650 | 7 | |a Hochschulschrift |2 gtt | |
655 | 7 | |0 (DE-588)4113937-9 |a Hochschulschrift |2 gnd-content | |
856 | 4 | 2 | |m DNB Datenaustausch |q application/pdf |u http://bvbr.bib-bvb.de:8991/F?func=service&doc_library=BVB01&local_base=BVB01&doc_number=009305203&sequence=000001&line_number=0001&func_code=DB_RECORDS&service_type=MEDIA |3 Inhaltsverzeichnis |
943 | 1 | |a oai:aleph.bib-bvb.de:BVB01-009305203 |
Datensatz im Suchindex
_version_ | 1812460911803236352 |
---|---|
adam_text |
INHALTSVERZEICHNIS
1
1.1
1*2
1
.
2.1
1
.
2.2
1.2.3
1.2.5
1
.
2.6
2
3
3.1
3.1.1
3.1.2
3.1.3
3.1.3
3.2
3.2.1
3.2.2
3.2.3
3.2.4
3.2.5
3.3
3.3.1
3.3.2
3.3.3
3.3.4
3.3.5
3.3.6.
3.3.7
3.3.8
3.3.9
EINFUEHRUNG
INTRAKORONARE GEFAESSSTUETZEN
IN-STENT-STENOSE
PATHOGENESE DER IN-STENT-STENOSE
KRITERIEN DER IN-STENT-STENOSE
ANGIOGRAFISCHE RESTENOSERATE NACH INTERVENTION DER IN-STENT-STENOSE
INTERVENTIONEILE THERAPIE DER IN-STENT-STENOSE
EXPERIMENTELLE THERAPIEANSAETZE DER IN-STENT-STENOSE
ZIELSETZUNG
PATIENTEN UND METHODEN
STUDIENDESIGN
ANLAGE
GROESSENORDNUNG
EINSCHLUSSKRITERIEN
AUSSCHLUSSKRITERIEN
ERFASSTE PATIENTENBEZOGENE, STENOSE- UND STENTSPEZIFISCHE PARAMETER
V
PATIENTENBEZOGENE PARAMETER
STENTSPEZIFISCHE PARAMETER
STENOSESPEZIFISCHE PARAMETER
VERFAHRENSSPEZIFISCHE PARAMETER
VERLAUFSSPEZIFISCHE PARAMETER
DEFINITIONEN
PRIMAERINTERVENTION
STENOSE
STENOSELAENGE
REFERENCE DIAMETER (RD)
MINIMAL LUMEN DIAMETER (MID)
PROZENTUALE STENOSE
PROZEDURALER ERFOLG
ACUTE GAIN
NETGAIN
-
4
-
BIBLIOGRAFISCHE INFORMATIONEN
HTTP://D-NB.INFO/960648631
3.3.10
3.3.11
3.3.12
3.3.13
3.3.14
3.4
3.4.1
3.4.2
3.4.3
3.5
3.5.1
3.5.2
3.5.3
3.6
4
.
4.1
4.1.1.
4.1.2
4.1.3
4.1.4
4.1.5
4.2
4.2.1
4.2.2
4.2.3
4.2.4
4.2.5
4.3
4.3.1
4.3.2
4.3.3
4.3.4
4
.
3
.
4.1
4
.
3
.
4.2
4.3.5
LATE LUMEN LOSS
REANGIOGRQFIERATE
RESTENOSE
RESTENOSERATE
STENTLAENGE
VERFAHREN
ROTATIONSANGIOPLASTIE
EXCIMER-LASER-ANGIOPLASTIE
PERKUTANE TRANSLUMINALE BALLONANGIOPLASTIE
QUANTITATIVE KORONARANALYSE
TECHNISCHE VORAUSSETZUNGEN
DAS KARDIOVASKULAERE MESSSYSTEM
DURCHFOEHRUNG DER QUANTITATIVEN KORONARANALYSE
DATENERFASSUNG UND STATISTISCHE AUSWERTUNG
ERGEBNISSE
BESCHREIBUNG DER IN-STENT-STENOSE
VERTEILUNG DER STENOSEN
EINTEILUNG ENTSPRECHEND STENOSELAENGE
VERTEILUNG DER STENOSELAENGE
VERTEILUNG DES STENOSEGRADES
ZUSAMMENHANG STENOSELAENGE - STENOSEGRAD
EINFLUSS VON STENTSPEZIFISCHEN PARAMETERN AUF DIE ENTSTEHUNG VON IN-
STENT-STENOSEN
VERTEILUNG DER STENTLAENGE
ZUSAMMENHANG STENTLAENGE - STENOSEGRAD
ZUSAMMENHANG STENTLAENGE - STENOSELAENGE
VERTEILUNG DER STENTDURCHMESSER
ZUSAMMENHANG STENTDURCHMESSER
-
STENOSEGRAD
THERAPIE DER IN-STENT-STENOSE
RESULTATE DER PRIMAERINTERVENTION
PROZEDURALER ERFOLG
ACUTE GAIN
EINFLUSS DES PARAMETERS
YY
REFERENZDURCHMESSER
"
AUF DAS INTERVENTIONSERGEBNIS
ZUSAMMENHANG REFERENZDURCHMESSER - PROZENTUALE STENOSE
ZUSAMMENHANG REFERENZDURCHMESSER - MUD
EINFLUSS DES PARAMETERS YYSTENTLAENGE" AUF DAS INTERVENTIONSERGEBNIS
-
5
-
4.4 KONTR OLLUNTER SUCHUNG
4.4.1 RESTENOSERATE
4.4.2 RESULTATE DER KONTROLLUNTERSUCHUNG
4.4.3 LATE LOSS
4.4.4 NET GAIN
4.4.5 REANGIOGRAFIERATE
4.4.6 EINFLUSS DES PARAMETERS YY REFERENZDURCHMESSER" AUF DAS
KONTROLLERGEBNIS
4.4.6.1 ZUSAMMENHANG REFERENZDURCHMESSER - PROZENTUALE STENOSE
4.4.6.2 ZUSAMMENHANG REFERENZDURCHMESSER - MLD
4.4.7 EINFLUSS DES PARAMETERS YYSTENTLAENGE" AUF DAS KONTROLLERGEBNIS
4.5 VORHERSAGE VON IN-STENT-RESTENOSEN
4.5.1 ABHAENGIGKEIT DES GRADES DER RESTENOSE BEI KONTROLLUNTERSUCHUNG VON
DER STENTLAENGE
VOR PRIMAERINTERVENTION
4.5.2 ABHAENGIGKEIT DES GRADES DER RESTENOSE BEI KONTROLLUNTERSUCHUNG VOM
STENTDURCH
MESSER VOR PRIMAERINTERVENTION
4.5.3 ABHAENGIGKEIT DES GRADES DER RESTENOSE BEI KONTROLLUNTERSUCHUNG VOM
GRAD DER
STENOSE VOR PRIMAERINTERVENTION
4.5.4 ABHAENGIGKEIT DES GRADES DER RESTENOSE BEI KONTROLLUNTERSUCHUNG VON
DER STENOSE
LAENGE VOR PRIMAERINTERVENTION
5. DISKUSSION
5.1 MORPHOLOGIE DER IN-STENT-STENOSE UND DEREN BEZIEHUNG ZUM STENT
5.2
VERGLEICH DER THERAPIEERGEBNISSE DER IN-STENT-STENOSE UNTER BERUECK
SICHTIGUNG VON R^FERENZDURCHMESSER UND STENTLAENGE
5.3 VERGLEICH DER KONTROLLERGEBNISSE UNTER BERUECKSICHTIGUNG VON
REFERENZ
DURCHMESSER UND STENTLAENGE
5.4 VORHERSAGE DER RESTENOSE
LITERATURVERZEICHNIS
THESEN |
any_adam_object | 1 |
author | Ambrosch, Heiko 1965- |
author_GND | (DE-588)122641493 |
author_facet | Ambrosch, Heiko 1965- |
author_role | aut |
author_sort | Ambrosch, Heiko 1965- |
author_variant | h a ha |
building | Verbundindex |
bvnumber | BV013620607 |
ctrlnum | (OCoLC)48717138 (DE-599)BVBBV013620607 |
discipline | Medizin |
format | Book |
fullrecord | <?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>00000nam a2200000 c 4500</leader><controlfield tag="001">BV013620607</controlfield><controlfield tag="003">DE-604</controlfield><controlfield tag="007">t</controlfield><controlfield tag="008">010228s2000 gw ad|| m||| 00||| ger d</controlfield><datafield tag="016" ind1="7" ind2=" "><subfield code="a">960648631</subfield><subfield code="2">DE-101</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(OCoLC)48717138</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-599)BVBBV013620607</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-604</subfield><subfield code="b">ger</subfield><subfield code="e">rakddb</subfield></datafield><datafield tag="041" ind1="0" ind2=" "><subfield code="a">ger</subfield></datafield><datafield tag="044" ind1=" " ind2=" "><subfield code="a">gw</subfield><subfield code="c">DE</subfield></datafield><datafield tag="049" ind1=" " ind2=" "><subfield code="a">DE-355</subfield></datafield><datafield tag="084" ind1=" " ind2=" "><subfield code="a">610</subfield><subfield code="2">sdnb</subfield></datafield><datafield tag="100" ind1="1" ind2=" "><subfield code="a">Ambrosch, Heiko</subfield><subfield code="d">1965-</subfield><subfield code="e">Verfasser</subfield><subfield code="0">(DE-588)122641493</subfield><subfield code="4">aut</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">Therapie der In-Stent-Stenose</subfield><subfield code="b">Vergleich von Excimerlaserangioplastie, Rotablation und konventioneller Ballonangioplastie</subfield><subfield code="c">eingereicht von Heiko Ambrosch</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">2000</subfield></datafield><datafield tag="300" ind1=" " ind2=" "><subfield code="a">106 Bl.</subfield><subfield code="b">Ill., graph. Darst. : 30 cm</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="b">txt</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="b">n</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="b">nc</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="500" ind1=" " ind2=" "><subfield code="a">Leipzig, Univ., Diss., 2000</subfield></datafield><datafield tag="650" ind1=" " ind2="7"><subfield code="a">Hochschulschrift</subfield><subfield code="2">gtt</subfield></datafield><datafield tag="655" ind1=" " ind2="7"><subfield code="0">(DE-588)4113937-9</subfield><subfield code="a">Hochschulschrift</subfield><subfield code="2">gnd-content</subfield></datafield><datafield tag="856" ind1="4" ind2="2"><subfield code="m">DNB Datenaustausch</subfield><subfield code="q">application/pdf</subfield><subfield code="u">http://bvbr.bib-bvb.de:8991/F?func=service&doc_library=BVB01&local_base=BVB01&doc_number=009305203&sequence=000001&line_number=0001&func_code=DB_RECORDS&service_type=MEDIA</subfield><subfield code="3">Inhaltsverzeichnis</subfield></datafield><datafield tag="943" ind1="1" ind2=" "><subfield code="a">oai:aleph.bib-bvb.de:BVB01-009305203</subfield></datafield></record></collection> |
genre | (DE-588)4113937-9 Hochschulschrift gnd-content |
genre_facet | Hochschulschrift |
id | DE-604.BV013620607 |
illustrated | Illustrated |
indexdate | 2024-10-09T18:10:19Z |
institution | BVB |
language | German |
oai_aleph_id | oai:aleph.bib-bvb.de:BVB01-009305203 |
oclc_num | 48717138 |
open_access_boolean | |
owner | DE-355 DE-BY-UBR |
owner_facet | DE-355 DE-BY-UBR |
physical | 106 Bl. Ill., graph. Darst. : 30 cm |
publishDate | 2000 |
publishDateSearch | 2000 |
publishDateSort | 2000 |
record_format | marc |
spelling | Ambrosch, Heiko 1965- Verfasser (DE-588)122641493 aut Therapie der In-Stent-Stenose Vergleich von Excimerlaserangioplastie, Rotablation und konventioneller Ballonangioplastie eingereicht von Heiko Ambrosch 2000 106 Bl. Ill., graph. Darst. : 30 cm txt rdacontent n rdamedia nc rdacarrier Leipzig, Univ., Diss., 2000 Hochschulschrift gtt (DE-588)4113937-9 Hochschulschrift gnd-content DNB Datenaustausch application/pdf http://bvbr.bib-bvb.de:8991/F?func=service&doc_library=BVB01&local_base=BVB01&doc_number=009305203&sequence=000001&line_number=0001&func_code=DB_RECORDS&service_type=MEDIA Inhaltsverzeichnis |
spellingShingle | Ambrosch, Heiko 1965- Therapie der In-Stent-Stenose Vergleich von Excimerlaserangioplastie, Rotablation und konventioneller Ballonangioplastie Hochschulschrift gtt |
subject_GND | (DE-588)4113937-9 |
title | Therapie der In-Stent-Stenose Vergleich von Excimerlaserangioplastie, Rotablation und konventioneller Ballonangioplastie |
title_auth | Therapie der In-Stent-Stenose Vergleich von Excimerlaserangioplastie, Rotablation und konventioneller Ballonangioplastie |
title_exact_search | Therapie der In-Stent-Stenose Vergleich von Excimerlaserangioplastie, Rotablation und konventioneller Ballonangioplastie |
title_full | Therapie der In-Stent-Stenose Vergleich von Excimerlaserangioplastie, Rotablation und konventioneller Ballonangioplastie eingereicht von Heiko Ambrosch |
title_fullStr | Therapie der In-Stent-Stenose Vergleich von Excimerlaserangioplastie, Rotablation und konventioneller Ballonangioplastie eingereicht von Heiko Ambrosch |
title_full_unstemmed | Therapie der In-Stent-Stenose Vergleich von Excimerlaserangioplastie, Rotablation und konventioneller Ballonangioplastie eingereicht von Heiko Ambrosch |
title_short | Therapie der In-Stent-Stenose |
title_sort | therapie der in stent stenose vergleich von excimerlaserangioplastie rotablation und konventioneller ballonangioplastie |
title_sub | Vergleich von Excimerlaserangioplastie, Rotablation und konventioneller Ballonangioplastie |
topic | Hochschulschrift gtt |
topic_facet | Hochschulschrift |
url | http://bvbr.bib-bvb.de:8991/F?func=service&doc_library=BVB01&local_base=BVB01&doc_number=009305203&sequence=000001&line_number=0001&func_code=DB_RECORDS&service_type=MEDIA |
work_keys_str_mv | AT ambroschheiko therapiederinstentstenosevergleichvonexcimerlaserangioplastierotablationundkonventionellerballonangioplastie |