DIN VDE 0100: Daten und Fakten für das Errichten elektrischer Anlagen von Gebäuden
Gespeichert in:
1. Verfasser: | |
---|---|
Format: | Buch |
Sprache: | German |
Veröffentlicht: |
Berlin [u.a.]
VDE-Verl.
2000
|
Schriftenreihe: | VDE-Schriftenreihe
105 |
Schlagworte: | |
Online-Zugang: | Inhaltsverzeichnis |
Beschreibung: | 215 S. graph. Darst. |
ISBN: | 3800723743 |
Internformat
MARC
LEADER | 00000nam a22000008cb4500 | ||
---|---|---|---|
001 | BV013303472 | ||
003 | DE-604 | ||
005 | 20170404 | ||
007 | t | ||
008 | 000808s2000 d||| |||| 00||| ger d | ||
016 | 7 | |a 959489053 |2 DE-101 | |
020 | |a 3800723743 |9 3-8007-2374-3 | ||
035 | |a (OCoLC)247394729 | ||
035 | |a (DE-599)BVBBV013303472 | ||
040 | |a DE-604 |b ger |e rakddb | ||
041 | 0 | |a ger | |
049 | |a DE-M487 |a DE-M490 |a DE-703 |a DE-210 |a DE-Aug4 |a DE-1102 |a DE-862 |a DE-858 |a DE-92 |a DE-634 |a DE-83 |a DE-525 |a DE-B768 |a DE-706 |a DE-91 | ||
084 | |a ZN 3020 |0 (DE-625)157283: |2 rvk | ||
084 | |a ZN 8950 |0 (DE-625)157656: |2 rvk | ||
084 | |a 620 |2 sdnb | ||
084 | |a 37 |2 sdnb | ||
084 | |a 19 |2 sdnb | ||
100 | 1 | |a Krefter, Karl-Heinz |d 1937- |e Verfasser |0 (DE-588)121455998 |4 aut | |
245 | 1 | 0 | |a DIN VDE 0100 |b Daten und Fakten für das Errichten elektrischer Anlagen von Gebäuden |c Karl-Heinz Krefter |
264 | 1 | |a Berlin [u.a.] |b VDE-Verl. |c 2000 | |
300 | |a 215 S. |b graph. Darst. | ||
336 | |b txt |2 rdacontent | ||
337 | |b n |2 rdamedia | ||
338 | |b nc |2 rdacarrier | ||
490 | 1 | |a VDE-Schriftenreihe |v 105 | |
630 | 0 | 7 | |a DIN VDE 0100 |0 (DE-588)4121840-1 |2 gnd |9 rswk-swf |
650 | 0 | 7 | |a Gebäude |0 (DE-588)4156127-2 |2 gnd |9 rswk-swf |
650 | 0 | 7 | |a Elektroinstallation |0 (DE-588)4014277-2 |2 gnd |9 rswk-swf |
655 | 7 | |0 (DE-588)4419668-4 |a Norm |2 gnd-content | |
689 | 0 | 0 | |a DIN VDE 0100 |0 (DE-588)4121840-1 |D u |
689 | 0 | |5 DE-604 | |
689 | 1 | 0 | |a Gebäude |0 (DE-588)4156127-2 |D s |
689 | 1 | 1 | |a Elektroinstallation |0 (DE-588)4014277-2 |D s |
689 | 1 | |5 DE-604 | |
830 | 0 | |a VDE-Schriftenreihe |v 105 |w (DE-604)BV023075735 |9 105 | |
856 | 4 | 2 | |m DNB Datenaustausch |q application/pdf |u http://bvbr.bib-bvb.de:8991/F?func=service&doc_library=BVB01&local_base=BVB01&doc_number=009070418&sequence=000001&line_number=0001&func_code=DB_RECORDS&service_type=MEDIA |3 Inhaltsverzeichnis |
999 | |a oai:aleph.bib-bvb.de:BVB01-009070418 |
Datensatz im Suchindex
DE-BY-862_location | 2000 |
---|---|
DE-BY-FWS_call_number | 2000/ZN 8950 K92 |
DE-BY-FWS_katkey | 180319 |
DE-BY-FWS_media_number | 083000329685 |
_version_ | 1806176086380249088 |
adam_text | VDE-SCHRIFTENREIHE NORMEN VERSTANDLICH
DIN VDE O1OO
DATEN UND FAKTEN FUR DAS ERRICHTEN
ELEKTRISCHER ANLAGEN VON GEBAUDEN
DIPL.-LNG. KARL-HEINZ KREFTER
105
VDE VERLAG * BERLIN * OFFENBACH
INHALT
VORWORT 5
1 GLIEDERUNG DER NORMENREIHE DIN VDE 0100
ELEKTRISCHE ANLAGEN VON GEBAUDEN 12
2 ANWENDUNGSBEREICH [100] 17
3 BEGRIFFE [200] 19
4 CHARAKTERISTISCHE MERKMALE [300] 33
5 SCHUTZ GEGEN ELEKTRISCHEN SCHLAG [410] 34
6 SCHUTZ GEGEN DIREKTES BERIIHREN (BASISSCHUTZ) [410] 35
6.1 SCHUTZ DURCH ISOLIERUNG 35
6.2 SCHUTZ DURCH ABDECKUNGEN ODER UMHIILLUNGEN 35
6.3 SCHUTZ DURCH HINDERNISSE 35
6.4 SCHUTZ DURCH ABSTAND 36
7 SCHUTZ BEI INDIREKTEM BERIIHREN (FEHLERSCHUTZ) [410] 37
7.1 SCHUTZ DURCH AUTOMUTISCHE ABSCHALTUNG DER STROMVERSORGUNG 37
7.2 SCHUTZ DURCH AUTOMATISCHE ABSCHALTUNG IM TN-SYSTEM
(NULLUNG) 40
7.3 SCHUTZ DURCH AUTOMATISCHE ABSCHALTUNG IM TT-SYSTEM
(FL-SCHUTZSCHALTUNG) 41
7.4 SCHUTZ DURCH ANWCNDUNG DES IT-SYSTEMS 42
7.5 SCHUTZISOLIERUNG 43
7.6 SCHUTZTRENNUNG 43
8 SCHUTZ SOWOHL GEGEN DIREKTES ALS AUCH BEI INDIREKTEM BERIIHREN
(SCHUTZ DURCH KLEINSPANNUNG) [410] 45
9 SCHUTZ GEGEN THERMISCHE EINFLIISSE [420, 482] 46
9.1 BRANDSCHUTZ 46
9.2 SCHUTZ GEGEN VERBRENNUNGEN (BRANDWUNDEN) 47
9.3 SCHUTZ GEGEN UBERHITZUNG 47
7
10 BRANDSCHUTZ BEI BESONDEREN RISIKEN UND GEFAHREN [482] 48
10.1 ERGANZENDE ANFORDERUNGEN FIIR FEUERGEFAHRDETE BETRIEBSSTATTEN ....
48
10.2 RAUME UND ORTE MIT BRENNBAREN BAUSTOFFEN 50
10.3 RAUME MIT UNERSETZBAREN GIITERN VON HOHEM WERT 50
11 SCHUTZ VON KABELN UND LEITUNGEN BEI UBERSTROM [430] 51
1.1 ART DER SCHUTZEINRICHTUNGEN 51
.2 SCHUTZ BEI UBERLAST 54
.3 ANORDNUNG DER SCHUTZEINRICHTUNGEN ZUM SCHUTZ BEI UBERLAST 55
.4 VERZICHT AUF DEN SCHUTZ BEI UBERLAST 55
.5 SCHUTZ BEI UBERLAST VON PARALLEL GESCHALTETEN LEITERN 56
.6 SCHUTZ BEI KURZSCHLUSS 56
.7 ANORDNUNG DER SCHUTZEINRICHTUNGEN ZUM SCHUTZ BEI KURZSCHLUSS. . . 59
.8 VERZICHT AUF DEN SCHUTZ BEI KURZSCHLUSS 59
.9 SCHUTZ BEI KURZSCHLUSS VON PARALLEL GESCHALTETEN LEITERN 60
.10 KOORDINIERUNG DES SCHUTZES BEI UBERLAST UND KURZSCHLUSS 60
12 SCHUTZ BEI UBERSPANNUNGEN [442,443, 444] 61
1
2.1 SCHUTZ BEI UBERSPANNUNGEN INFOLGE ATMOSPHARISCHER EINFLIISSE 61
I
MIT
SCHUTZ BEI UBERSPANNUNGEN DURCH SCHALTVORGANGE ....
12.3 SCHUTZ BEI UBERSPANNUNGEN BEI ERDSCHLIISSEN IN NETZEN
HOHERER SPANNUNG 6
12.4 SCHUTZ BEI UBERSPANNUNGEN INFOLGE ELEKTROMAGNETISCHER
STORUNGEN 70
13 SCHUTZ GEGEN UNTERSPANNUNG [450] 72
14 TRENNEN UND SCHALTEN [460] 73
14.1 TRENNEN 73
14.2 AUSSCHALTEN FUR MECHANISCHE INSTANDHALTUNG 74
14.3 NOT-SCHALTUNGEN 74
14.4 BETRIEBSMABIGES SCHALTEN 75
[510] 77
77
15.2 KENNZEICHNUNG 77
15.3 BEEINFLUSSUNG 78
15 4 ELEKTROMAGNETISCHE VERTRAGLICHKEIT 78
8
16 KABEL- UND LEITUNGSSYSTEME [520] 79
16.1 UMGEBUNGSEINFLIISSE 79
16.2 ZULASSIGC STROMBELASTBARKEIT 89
16.3 MINDESTQUERSCHNITTE VON LEITERN 89
16.4 SPANNUNGSFALL IN VERBRAUCHERANLAGEN 91
16.5 ELEKTRISCHE VERBINDUNGEN 91
16.6 BEGRENZUNG VON BRANDEN 91
16.7 NAHE ZU ANDEREN ELEKTRISCHEN ANLAGEN 92
16.8 NIIHE ZU NICHT ELEKTRISCHEN ANLAGEN 92
16.9 INSTANDHALTUNG 92
16.10 ANWENDUNGSBEISPIELE 93
17 ERDUNG [540] 122
17.1 ERDUNGSANLAGE 122
17.2 ERDER 122
17.3 ERDUNGSLEITER 125
17.4 HAUPTERDUNGSKLEMMC ODER -SCHIENE 125
17.5 VERBINDUNG ZWISCHEN ERDUNGSANLAGEN VERSCHIEDENER SYSTEME 125
18 SCHUTZLEITER [540] 127
18.1 QUERSCHNITT 127
18.2 ARTEN VON SCHUTZLEITERN 127
18.3 PEN-LCITER 129
18.4 VERTRAGLICHKEIT VON ANLAGEN DER INFORMATIONSTECHNIK MIT
PEN-LEITERN IN GEBAUDEN. FREMDSPANNUNGSARMER
POTENTIALAUSGLEICH I 30
19 POTENTIALAUSGLEICH [540| 131
20 ERDUNG UND POTENTIALAUSGLEICH FUR ANLAGEN DER
INFORMATIONSTECHNIK |548| 132
21 STECKVORRICHTUNGEN [550] 134
22 NIEDERSPANNUNGS-STROMER/.EUGUNGSANLAGEN [551] 136
23 LEUCHTEN UND BELEUCHTUNGSANLAGEN [559] 139
24 ELEKTRISCHE ANLAGEN FUR SICHERHEITSZWECKE [5601 141
25 PRIIFUNGEN [610, 620 E]
L44
25.1 NACHWEISE VOR DER ERSTEN INBETRIEBNAHME 144
25.2 WIEDERKEHRENDE NACHWEISE I
49
26 ELEKTRISCHE ANLAGEN IN BETRIEBSSTATTEN, RAUMEN UND ANLAGEN
BESONDERER ART 5*
27 ORTE MIT BADEWANNE ODER DUSCHE [701] 151
28 SCHWIMMBADER UND ANDERE BECKEN [702] 156
29 RAUME MIT ELEKTRISCHEN SAUNA-HEIZGERATEN [703] 162
30 BAUSTELLEN [704] 164
31 LANDWIRTSCHAFTLICHE UND GARTENBAULICHE ANWESEN [705] 166
32 LEITFAHIGE BEREICHEMIT BEGRENZTER BEWEGUNGSFREIHEIT [706] 169
33 CAMPINGPLATZE UND CARAVANS [708] 171
34 MARINAS [709] 175
35 AUSSTELLUNGEN, MESSESTANDE, JAHRMARKTE, ZIRKUS [711 E, 722) .... 177
36 PHOTOVOLTAIK-ANLAGEN [712 E] 181
37 MIIBEL [713 E, 724] 185
38 BELEUCHTUNGSANLAGEN IM FREIEN [714] 187
39 KLEINSPANNUNGS-BELEUCHTUNGSANLAGEN [715 E] 189
40 HILFSSTROMKREISE [716 E] 192
41 BEWEGLICHE UND ORTSVERANDERLICHE ELEKTRISCHE ANLAGEN [717] 196
42 EINSATZ VON BETRIEBSMITTELN MIT BEGRENZUNG DES FEHLERSTROMS
UND/ODER MIT GLEICHSTROMANTEILEN IM FEHLERSTROM [719] 198
43 UNTERRICHTSRAUME MIT EXPERIMENTIERSTANDEN [723 E] 199
44 AUFSTELLEN UND ANSCHLIELKN VON SCHALTANLAGEN UND
VERTEILERN [729] 201
45 ELEKTRISCHE BETRIEBSSTATTEN UND ABGESCHLOSSENE ELEKTRISCHE
BETRIEBSSTATTEN [731] 204
46 HAUSANSCHLIISSE IN OFFENTLICHEN KABELNETZEN [732] 206
47 NIEDERSPANNUNGSSTROMKREISE IN
HOCHSPANNUNGSSCHALTFELDERN [736] 208
10
48 FEUCHTE UND NASSE BEREICHE UND RAUME UND ANLAGEN
IM FREIEN [737] 209
49 ZUSATZLICHER SCHUTZ IN WOHNUNGEN DURCH RCD
MIT I
M
30 MA [739] 210
50 FUBBODEN- UND DECKENFLACHENHEIZUNGEN [753 E] 211
STICHWORTVERZEICHNIS 213
II
|
any_adam_object | 1 |
author | Krefter, Karl-Heinz 1937- |
author_GND | (DE-588)121455998 |
author_facet | Krefter, Karl-Heinz 1937- |
author_role | aut |
author_sort | Krefter, Karl-Heinz 1937- |
author_variant | k h k khk |
building | Verbundindex |
bvnumber | BV013303472 |
classification_rvk | ZN 3020 ZN 8950 |
ctrlnum | (OCoLC)247394729 (DE-599)BVBBV013303472 |
discipline | Maschinenbau / Maschinenwesen Elektrotechnik / Elektronik / Nachrichtentechnik |
format | Book |
fullrecord | <?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01900nam a22004698cb4500</leader><controlfield tag="001">BV013303472</controlfield><controlfield tag="003">DE-604</controlfield><controlfield tag="005">20170404 </controlfield><controlfield tag="007">t</controlfield><controlfield tag="008">000808s2000 d||| |||| 00||| ger d</controlfield><datafield tag="016" ind1="7" ind2=" "><subfield code="a">959489053</subfield><subfield code="2">DE-101</subfield></datafield><datafield tag="020" ind1=" " ind2=" "><subfield code="a">3800723743</subfield><subfield code="9">3-8007-2374-3</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(OCoLC)247394729</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-599)BVBBV013303472</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-604</subfield><subfield code="b">ger</subfield><subfield code="e">rakddb</subfield></datafield><datafield tag="041" ind1="0" ind2=" "><subfield code="a">ger</subfield></datafield><datafield tag="049" ind1=" " ind2=" "><subfield code="a">DE-M487</subfield><subfield code="a">DE-M490</subfield><subfield code="a">DE-703</subfield><subfield code="a">DE-210</subfield><subfield code="a">DE-Aug4</subfield><subfield code="a">DE-1102</subfield><subfield code="a">DE-862</subfield><subfield code="a">DE-858</subfield><subfield code="a">DE-92</subfield><subfield code="a">DE-634</subfield><subfield code="a">DE-83</subfield><subfield code="a">DE-525</subfield><subfield code="a">DE-B768</subfield><subfield code="a">DE-706</subfield><subfield code="a">DE-91</subfield></datafield><datafield tag="084" ind1=" " ind2=" "><subfield code="a">ZN 3020</subfield><subfield code="0">(DE-625)157283:</subfield><subfield code="2">rvk</subfield></datafield><datafield tag="084" ind1=" " ind2=" "><subfield code="a">ZN 8950</subfield><subfield code="0">(DE-625)157656:</subfield><subfield code="2">rvk</subfield></datafield><datafield tag="084" ind1=" " ind2=" "><subfield code="a">620</subfield><subfield code="2">sdnb</subfield></datafield><datafield tag="084" ind1=" " ind2=" "><subfield code="a">37</subfield><subfield code="2">sdnb</subfield></datafield><datafield tag="084" ind1=" " ind2=" "><subfield code="a">19</subfield><subfield code="2">sdnb</subfield></datafield><datafield tag="100" ind1="1" ind2=" "><subfield code="a">Krefter, Karl-Heinz</subfield><subfield code="d">1937-</subfield><subfield code="e">Verfasser</subfield><subfield code="0">(DE-588)121455998</subfield><subfield code="4">aut</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">DIN VDE 0100</subfield><subfield code="b">Daten und Fakten für das Errichten elektrischer Anlagen von Gebäuden</subfield><subfield code="c">Karl-Heinz Krefter</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="a">Berlin [u.a.]</subfield><subfield code="b">VDE-Verl.</subfield><subfield code="c">2000</subfield></datafield><datafield tag="300" ind1=" " ind2=" "><subfield code="a">215 S.</subfield><subfield code="b">graph. Darst.</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="b">txt</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="b">n</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="b">nc</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="490" ind1="1" ind2=" "><subfield code="a">VDE-Schriftenreihe</subfield><subfield code="v">105</subfield></datafield><datafield tag="630" ind1="0" ind2="7"><subfield code="a">DIN VDE 0100</subfield><subfield code="0">(DE-588)4121840-1</subfield><subfield code="2">gnd</subfield><subfield code="9">rswk-swf</subfield></datafield><datafield tag="650" ind1="0" ind2="7"><subfield code="a">Gebäude</subfield><subfield code="0">(DE-588)4156127-2</subfield><subfield code="2">gnd</subfield><subfield code="9">rswk-swf</subfield></datafield><datafield tag="650" ind1="0" ind2="7"><subfield code="a">Elektroinstallation</subfield><subfield code="0">(DE-588)4014277-2</subfield><subfield code="2">gnd</subfield><subfield code="9">rswk-swf</subfield></datafield><datafield tag="655" ind1=" " ind2="7"><subfield code="0">(DE-588)4419668-4</subfield><subfield code="a">Norm</subfield><subfield code="2">gnd-content</subfield></datafield><datafield tag="689" ind1="0" ind2="0"><subfield code="a">DIN VDE 0100</subfield><subfield code="0">(DE-588)4121840-1</subfield><subfield code="D">u</subfield></datafield><datafield tag="689" ind1="0" ind2=" "><subfield code="5">DE-604</subfield></datafield><datafield tag="689" ind1="1" ind2="0"><subfield code="a">Gebäude</subfield><subfield code="0">(DE-588)4156127-2</subfield><subfield code="D">s</subfield></datafield><datafield tag="689" ind1="1" ind2="1"><subfield code="a">Elektroinstallation</subfield><subfield code="0">(DE-588)4014277-2</subfield><subfield code="D">s</subfield></datafield><datafield tag="689" ind1="1" ind2=" "><subfield code="5">DE-604</subfield></datafield><datafield tag="830" ind1=" " ind2="0"><subfield code="a">VDE-Schriftenreihe</subfield><subfield code="v">105</subfield><subfield code="w">(DE-604)BV023075735</subfield><subfield code="9">105</subfield></datafield><datafield tag="856" ind1="4" ind2="2"><subfield code="m">DNB Datenaustausch</subfield><subfield code="q">application/pdf</subfield><subfield code="u">http://bvbr.bib-bvb.de:8991/F?func=service&doc_library=BVB01&local_base=BVB01&doc_number=009070418&sequence=000001&line_number=0001&func_code=DB_RECORDS&service_type=MEDIA</subfield><subfield code="3">Inhaltsverzeichnis</subfield></datafield><datafield tag="999" ind1=" " ind2=" "><subfield code="a">oai:aleph.bib-bvb.de:BVB01-009070418</subfield></datafield></record></collection> |
genre | (DE-588)4419668-4 Norm gnd-content |
genre_facet | Norm |
id | DE-604.BV013303472 |
illustrated | Illustrated |
indexdate | 2024-08-01T11:15:44Z |
institution | BVB |
isbn | 3800723743 |
language | German |
oai_aleph_id | oai:aleph.bib-bvb.de:BVB01-009070418 |
oclc_num | 247394729 |
open_access_boolean | |
owner | DE-M487 DE-M490 DE-703 DE-210 DE-Aug4 DE-1102 DE-862 DE-BY-FWS DE-858 DE-92 DE-634 DE-83 DE-525 DE-B768 DE-706 DE-91 DE-BY-TUM |
owner_facet | DE-M487 DE-M490 DE-703 DE-210 DE-Aug4 DE-1102 DE-862 DE-BY-FWS DE-858 DE-92 DE-634 DE-83 DE-525 DE-B768 DE-706 DE-91 DE-BY-TUM |
physical | 215 S. graph. Darst. |
publishDate | 2000 |
publishDateSearch | 2000 |
publishDateSort | 2000 |
publisher | VDE-Verl. |
record_format | marc |
series | VDE-Schriftenreihe |
series2 | VDE-Schriftenreihe |
spellingShingle | Krefter, Karl-Heinz 1937- DIN VDE 0100 Daten und Fakten für das Errichten elektrischer Anlagen von Gebäuden VDE-Schriftenreihe DIN VDE 0100 (DE-588)4121840-1 gnd Gebäude (DE-588)4156127-2 gnd Elektroinstallation (DE-588)4014277-2 gnd |
subject_GND | (DE-588)4121840-1 (DE-588)4156127-2 (DE-588)4014277-2 (DE-588)4419668-4 |
title | DIN VDE 0100 Daten und Fakten für das Errichten elektrischer Anlagen von Gebäuden |
title_auth | DIN VDE 0100 Daten und Fakten für das Errichten elektrischer Anlagen von Gebäuden |
title_exact_search | DIN VDE 0100 Daten und Fakten für das Errichten elektrischer Anlagen von Gebäuden |
title_full | DIN VDE 0100 Daten und Fakten für das Errichten elektrischer Anlagen von Gebäuden Karl-Heinz Krefter |
title_fullStr | DIN VDE 0100 Daten und Fakten für das Errichten elektrischer Anlagen von Gebäuden Karl-Heinz Krefter |
title_full_unstemmed | DIN VDE 0100 Daten und Fakten für das Errichten elektrischer Anlagen von Gebäuden Karl-Heinz Krefter |
title_short | DIN VDE 0100 |
title_sort | din vde 0100 daten und fakten fur das errichten elektrischer anlagen von gebauden |
title_sub | Daten und Fakten für das Errichten elektrischer Anlagen von Gebäuden |
topic | DIN VDE 0100 (DE-588)4121840-1 gnd Gebäude (DE-588)4156127-2 gnd Elektroinstallation (DE-588)4014277-2 gnd |
topic_facet | DIN VDE 0100 Gebäude Elektroinstallation Norm |
url | http://bvbr.bib-bvb.de:8991/F?func=service&doc_library=BVB01&local_base=BVB01&doc_number=009070418&sequence=000001&line_number=0001&func_code=DB_RECORDS&service_type=MEDIA |
volume_link | (DE-604)BV023075735 |
work_keys_str_mv | AT krefterkarlheinz dinvde0100datenundfaktenfurdaserrichtenelektrischeranlagenvongebauden |
Inhaltsverzeichnis
Schweinfurt Zentralbibliothek Lesesaal
Signatur: |
2000 ZN 8950 K92 |
---|---|
Exemplar 1 | ausleihbar Verfügbar Bestellen |