Assessment of interfacial shear and wall heat transfer of RELAP5, MOD2, 36.02 during reflooding:
Gespeichert in:
Hauptverfasser: | , , |
---|---|
Format: | Buch |
Sprache: | German |
Veröffentlicht: |
Würenlingen
EIR
1987
|
Schriftenreihe: | EIR-Bericht
624 |
Online-Zugang: | Inhaltsverzeichnis |
Beschreibung: | 22, [23] S. graph. Darst. |
Internformat
MARC
LEADER | 00000nam a2200000 cb4500 | ||
---|---|---|---|
001 | BV024610447 | ||
003 | DE-604 | ||
005 | 20090910 | ||
007 | t | ||
008 | 090924s1987 d||| |||| 00||| ger d | ||
015 | |a 87,B34,0316 |2 dnb | ||
016 | 7 | |a 870934287 |2 DE-101 | |
035 | |a (OCoLC)721414540 | ||
035 | |a (DE-599)BVBBV024610447 | ||
040 | |a DE-604 |b ger |e rakwb | ||
041 | 0 | |a ger | |
049 | |a DE-83 | ||
100 | 1 | |a Analytis, Gerassimos Th. |e Verfasser |4 aut | |
245 | 1 | 0 | |a Assessment of interfacial shear and wall heat transfer of RELAP5, MOD2, 36.02 during reflooding |c G. Th. Analytis ; M. Richner ; S. N. Aksan |
264 | 1 | |a Würenlingen |b EIR |c 1987 | |
300 | |a 22, [23] S. |b graph. Darst. | ||
336 | |b txt |2 rdacontent | ||
337 | |b n |2 rdamedia | ||
338 | |b nc |2 rdacarrier | ||
490 | 1 | |a EIR-Bericht |v 624 | |
700 | 1 | |a Richner, Martin |e Verfasser |4 aut | |
700 | 1 | |a Aksan, Susret N. |e Verfasser |4 aut | |
830 | 0 | |a EIR-Bericht |v 624 |w (DE-604)BV008919309 |9 624 | |
856 | 4 | 2 | |m DNB Datenaustausch |q application/pdf |u http://bvbr.bib-bvb.de:8991/F?func=service&doc_library=BVB01&local_base=BVB01&doc_number=018583196&sequence=000001&line_number=0001&func_code=DB_RECORDS&service_type=MEDIA |3 Inhaltsverzeichnis |
943 | 1 | |a oai:aleph.bib-bvb.de:BVB01-018583196 |
Datensatz im Suchindex
_version_ | 1807594643576061952 |
---|---|
adam_text |
CONTENTS
1
INTRODUCTION
4
2
DESCRIPTION
OF
THE
NEPTUN
FACILITY
AND
EXPERIMENTAL
MATRIX
4
3
IMPLEMENTATION
OF
A
NEW
BUBBLY/SLUG
INTERFACIAL
SHEAR
CORRELA
TION
IN
RELAP5/MOD2/36.02
5
4
ANALYSIS
OF
REFLOODING
EXPERIMENTS
WITH
RELAP5/MOD2/36.02
AND
ADDITIONAL
CODE
MODIFICATIONS
9
4.1
BASE-CASE
CALCULATIONS
.
9
4.2
RELAP5/MOD2/36.02
POST-CHF
WALL
HEAT
TRANSFER
DURING
RE
FLOODING
.
10
4.3
MODIFICATIONS
IN
REFLOODING
WALL
HEAT
TRANSFER
PACKAGE
OF
RELAP5/MOD2
12
4.4
MODIFICATIONS
IN
THE
INTERFACIAL
SHEAR
PACKAGE
OF
RELAP5/MOD2/36.02
14
4.5
SUPPRESSION
OF
VOID
FRACTION
DISCONTINUITIES
NEAR
THE
QUENCH
FRONT
15
4.6
MODIFICATION
OF
THE
WEISMANN
CORRELATION
AND
ITS
EFFECT
ON
QUENCH
TEMPERATURES
.
16
5
SUMMARY
AND
CONCLUDING
DISCUSSIONS
18 |
any_adam_object | 1 |
author | Analytis, Gerassimos Th Richner, Martin Aksan, Susret N. |
author_facet | Analytis, Gerassimos Th Richner, Martin Aksan, Susret N. |
author_role | aut aut aut |
author_sort | Analytis, Gerassimos Th |
author_variant | g t a gt gta m r mr s n a sn sna |
building | Verbundindex |
bvnumber | BV024610447 |
ctrlnum | (OCoLC)721414540 (DE-599)BVBBV024610447 |
format | Book |
fullrecord | <?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>00000nam a2200000 cb4500</leader><controlfield tag="001">BV024610447</controlfield><controlfield tag="003">DE-604</controlfield><controlfield tag="005">20090910</controlfield><controlfield tag="007">t</controlfield><controlfield tag="008">090924s1987 d||| |||| 00||| ger d</controlfield><datafield tag="015" ind1=" " ind2=" "><subfield code="a">87,B34,0316</subfield><subfield code="2">dnb</subfield></datafield><datafield tag="016" ind1="7" ind2=" "><subfield code="a">870934287</subfield><subfield code="2">DE-101</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(OCoLC)721414540</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-599)BVBBV024610447</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-604</subfield><subfield code="b">ger</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="041" ind1="0" ind2=" "><subfield code="a">ger</subfield></datafield><datafield tag="049" ind1=" " ind2=" "><subfield code="a">DE-83</subfield></datafield><datafield tag="100" ind1="1" ind2=" "><subfield code="a">Analytis, Gerassimos Th.</subfield><subfield code="e">Verfasser</subfield><subfield code="4">aut</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">Assessment of interfacial shear and wall heat transfer of RELAP5, MOD2, 36.02 during reflooding</subfield><subfield code="c">G. Th. Analytis ; M. Richner ; S. N. Aksan</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="a">Würenlingen</subfield><subfield code="b">EIR</subfield><subfield code="c">1987</subfield></datafield><datafield tag="300" ind1=" " ind2=" "><subfield code="a">22, [23] S.</subfield><subfield code="b">graph. Darst.</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="b">txt</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="b">n</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="b">nc</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="490" ind1="1" ind2=" "><subfield code="a">EIR-Bericht</subfield><subfield code="v">624</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Richner, Martin</subfield><subfield code="e">Verfasser</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Aksan, Susret N.</subfield><subfield code="e">Verfasser</subfield><subfield code="4">aut</subfield></datafield><datafield tag="830" ind1=" " ind2="0"><subfield code="a">EIR-Bericht</subfield><subfield code="v">624</subfield><subfield code="w">(DE-604)BV008919309</subfield><subfield code="9">624</subfield></datafield><datafield tag="856" ind1="4" ind2="2"><subfield code="m">DNB Datenaustausch</subfield><subfield code="q">application/pdf</subfield><subfield code="u">http://bvbr.bib-bvb.de:8991/F?func=service&doc_library=BVB01&local_base=BVB01&doc_number=018583196&sequence=000001&line_number=0001&func_code=DB_RECORDS&service_type=MEDIA</subfield><subfield code="3">Inhaltsverzeichnis</subfield></datafield><datafield tag="943" ind1="1" ind2=" "><subfield code="a">oai:aleph.bib-bvb.de:BVB01-018583196</subfield></datafield></record></collection> |
id | DE-604.BV024610447 |
illustrated | Illustrated |
indexdate | 2024-08-17T01:03:04Z |
institution | BVB |
language | German |
oai_aleph_id | oai:aleph.bib-bvb.de:BVB01-018583196 |
oclc_num | 721414540 |
open_access_boolean | |
owner | DE-83 |
owner_facet | DE-83 |
physical | 22, [23] S. graph. Darst. |
publishDate | 1987 |
publishDateSearch | 1987 |
publishDateSort | 1987 |
publisher | EIR |
record_format | marc |
series | EIR-Bericht |
series2 | EIR-Bericht |
spelling | Analytis, Gerassimos Th. Verfasser aut Assessment of interfacial shear and wall heat transfer of RELAP5, MOD2, 36.02 during reflooding G. Th. Analytis ; M. Richner ; S. N. Aksan Würenlingen EIR 1987 22, [23] S. graph. Darst. txt rdacontent n rdamedia nc rdacarrier EIR-Bericht 624 Richner, Martin Verfasser aut Aksan, Susret N. Verfasser aut EIR-Bericht 624 (DE-604)BV008919309 624 DNB Datenaustausch application/pdf http://bvbr.bib-bvb.de:8991/F?func=service&doc_library=BVB01&local_base=BVB01&doc_number=018583196&sequence=000001&line_number=0001&func_code=DB_RECORDS&service_type=MEDIA Inhaltsverzeichnis |
spellingShingle | Analytis, Gerassimos Th Richner, Martin Aksan, Susret N. Assessment of interfacial shear and wall heat transfer of RELAP5, MOD2, 36.02 during reflooding EIR-Bericht |
title | Assessment of interfacial shear and wall heat transfer of RELAP5, MOD2, 36.02 during reflooding |
title_auth | Assessment of interfacial shear and wall heat transfer of RELAP5, MOD2, 36.02 during reflooding |
title_exact_search | Assessment of interfacial shear and wall heat transfer of RELAP5, MOD2, 36.02 during reflooding |
title_full | Assessment of interfacial shear and wall heat transfer of RELAP5, MOD2, 36.02 during reflooding G. Th. Analytis ; M. Richner ; S. N. Aksan |
title_fullStr | Assessment of interfacial shear and wall heat transfer of RELAP5, MOD2, 36.02 during reflooding G. Th. Analytis ; M. Richner ; S. N. Aksan |
title_full_unstemmed | Assessment of interfacial shear and wall heat transfer of RELAP5, MOD2, 36.02 during reflooding G. Th. Analytis ; M. Richner ; S. N. Aksan |
title_short | Assessment of interfacial shear and wall heat transfer of RELAP5, MOD2, 36.02 during reflooding |
title_sort | assessment of interfacial shear and wall heat transfer of relap5 mod2 36 02 during reflooding |
url | http://bvbr.bib-bvb.de:8991/F?func=service&doc_library=BVB01&local_base=BVB01&doc_number=018583196&sequence=000001&line_number=0001&func_code=DB_RECORDS&service_type=MEDIA |
volume_link | (DE-604)BV008919309 |
work_keys_str_mv | AT analytisgerassimosth assessmentofinterfacialshearandwallheattransferofrelap5mod23602duringreflooding AT richnermartin assessmentofinterfacialshearandwallheattransferofrelap5mod23602duringreflooding AT aksansusretn assessmentofinterfacialshearandwallheattransferofrelap5mod23602duringreflooding |