Influence of calorimeter calibration errors on the measurement of deep inelastic scattering:
Gespeichert in:
1. Verfasser: | |
---|---|
Format: | Abschlussarbeit Buch |
Sprache: | German |
Veröffentlicht: |
Hamburg
[Dt. Elektronen-Synchrotron]
1992
|
Schlagworte: | |
Online-Zugang: | Inhaltsverzeichnis |
Beschreibung: | IX, 137 Sp. graph. Darst. 30 cm |
Internformat
MARC
LEADER | 00000nam a2200000 c 4500 | ||
---|---|---|---|
001 | BV024609762 | ||
003 | DE-604 | ||
005 | 20090910 | ||
007 | t | ||
008 | 090924s1992 d||| m||| 00||| ger d | ||
015 | |a 92,B25,0329 |2 dnb | ||
016 | 7 | |a 920723225 |2 DE-101 | |
035 | |a (OCoLC)722386097 | ||
035 | |a (DE-599)BVBBV024609762 | ||
040 | |a DE-604 |b ger |e rakwb | ||
041 | 0 | |a ger | |
049 | |a DE-83 |a DE-11 | ||
084 | |a UN 3040 |0 (DE-625)145972: |2 rvk | ||
088 | |a DESY F 35 92 01 | ||
100 | 1 | |a Woeniger, Torsten |e Verfasser |4 aut | |
245 | 1 | 0 | |a Influence of calorimeter calibration errors on the measurement of deep inelastic scattering |c by T. Woeniger |
264 | 1 | |a Hamburg |b [Dt. Elektronen-Synchrotron] |c 1992 | |
300 | |a IX, 137 Sp. |b graph. Darst. |c 30 cm | ||
336 | |b txt |2 rdacontent | ||
337 | |b n |2 rdamedia | ||
338 | |b nc |2 rdacarrier | ||
502 | |a Zugl.: Hamburg, Univ., Diss., 1991 | ||
650 | 0 | 7 | |a Messfehler |0 (DE-588)4133270-2 |2 gnd |9 rswk-swf |
650 | 0 | 7 | |a Fehler |0 (DE-588)4016606-5 |2 gnd |9 rswk-swf |
650 | 0 | 7 | |a Kalibrieren |g Messtechnik |0 (DE-588)4198763-9 |2 gnd |9 rswk-swf |
650 | 0 | 7 | |a Strahlungskalorimeter |0 (DE-588)4210218-2 |2 gnd |9 rswk-swf |
650 | 0 | 7 | |a Messung |0 (DE-588)4038852-9 |2 gnd |9 rswk-swf |
650 | 0 | 7 | |a Tiefinelastische Streuung |0 (DE-588)4185432-9 |2 gnd |9 rswk-swf |
650 | 0 | 7 | |a Kalorimeter |0 (DE-588)4163121-3 |2 gnd |9 rswk-swf |
655 | 7 | |0 (DE-588)4113937-9 |a Hochschulschrift |2 gnd-content | |
689 | 0 | 0 | |a Tiefinelastische Streuung |0 (DE-588)4185432-9 |D s |
689 | 0 | 1 | |a Messung |0 (DE-588)4038852-9 |D s |
689 | 0 | 2 | |a Kalorimeter |0 (DE-588)4163121-3 |D s |
689 | 0 | 3 | |a Kalibrieren |g Messtechnik |0 (DE-588)4198763-9 |D s |
689 | 0 | 4 | |a Fehler |0 (DE-588)4016606-5 |D s |
689 | 0 | |5 DE-604 | |
689 | 1 | 0 | |a Tiefinelastische Streuung |0 (DE-588)4185432-9 |D s |
689 | 1 | 1 | |a Strahlungskalorimeter |0 (DE-588)4210218-2 |D s |
689 | 1 | 2 | |a Kalibrieren |g Messtechnik |0 (DE-588)4198763-9 |D s |
689 | 1 | |5 DE-604 | |
689 | 2 | 0 | |a Tiefinelastische Streuung |0 (DE-588)4185432-9 |D s |
689 | 2 | 1 | |a Kalorimeter |0 (DE-588)4163121-3 |D s |
689 | 2 | 2 | |a Messfehler |0 (DE-588)4133270-2 |D s |
689 | 2 | |8 1\p |5 DE-604 | |
856 | 4 | 2 | |m DNB Datenaustausch |q application/pdf |u http://bvbr.bib-bvb.de:8991/F?func=service&doc_library=BVB01&local_base=BVB01&doc_number=018582565&sequence=000001&line_number=0001&func_code=DB_RECORDS&service_type=MEDIA |3 Inhaltsverzeichnis |
883 | 1 | |8 1\p |a cgwrk |d 20201028 |q DE-101 |u https://d-nb.info/provenance/plan#cgwrk | |
943 | 1 | |a oai:aleph.bib-bvb.de:BVB01-018582565 |
Datensatz im Suchindex
_version_ | 1807321368734203904 |
---|---|
adam_text |
CONTENTS
ABSTRACT
I
ZUSAMMENFASSUNG
I
1
INTRODUCTION
1
2
THE
ZEUS
-
DETECTOR
4
2.1
REQUIREMENTS
FOR
HERA
DETECTORS
.
4
2.2
COMPONENTS
OF
THE
ZEUS
DETECTOR
.
5
2.2.1
CENTRAL
TRACKING
SYSTEM
.
5
2.2.2
HADRON
ELECTRON
SEPARATOR
(HES)
.
8
2.2.3
HIGH
RESOLUTION
CALORIMETER
.
8
2.2.4
BACKING
CALORIMETER
(BAC)
.
9
2.2.5
MNON
CHAMBERS
.
9
2.2.6
LEADING
PROTON
SPECTROMETER
(LPS)
.
9
2.2.7
LUMINOSITY
MONITOR
.
10
3
DATA
ACQUISITION
AND
TRIGGER
SYSTEM
11
3.1
OVERVIEW
.
11
3.2 FIRST
LEVEL
TRIGGER
(FLT)
.
13
3.3
SECOND
LEVEL
TRIGGER
(SLT)
.
16
3.4
EVENTBUILDER
(EVB)
.
16
3.4.1
CONCEPTS
FOR
A
TRANSPUTER
BASED
EVENTBUILDER
.
18
3.4.2
STRUCTURE
OF
THE
EVENTBUILDER
.
21
3.4.3
PERFORMANCE
.
22
3.5
THIRD
LEVEL
TRIGGER
(TLT)
.
22
4
CALORIMETRY
25
4.1
ELECTROMAGNETIC
SHOWERS
.
27
4.2
HADRONIC
SHOWERS
.
31
4.3
ENERGY
RESOLUTION
OF
SAMPLING
CALORIMETERS
.
33
4.3.1
ENERGY
RESOLUTION
FOR
ELECTROMAGNETIC
SHOWERS
.
33
4.3.2
ENERGY
RESOLUTION
FOR
HADRONIC
SHOWERS
.
33
5
THE
ZEUS
CALORIMETER
36
5.1
PRINCIPLE
.
36
5.2
LAYOUT
OF
THE
ZEUS
CALORIMETER
.
36
5.2.1
OVERVIEW
.
36
5.2.2
DESCRIPTION
OF
A
(FCAL-)MODULE
.
37
5.2.3
READOUT
.
44
5.3
DIGITAL
CARD
.
46
5.4
CALIBRATION
CONSTANTS
.
47
6
CALIBRATION
OF
THE
ZEUS
CALORIMETER
P
52
6.1
BEAM
INDEPENDENT
CALIBRATION
METHODS
.
52
6.1.1
OVERVIEW
.
52
6.1.2
RANDOM
TRIGGERS
.
52
6.1.3
LIGHT
PULSER
SYSTEM
.
53
6.1.4
COBALT
SOURCE
CALIBRATION
.
53
6.1.5
URANIUM
SIGNAL
(UNO)
.
54
6.1.6
COMPLETE
OFF
BEAM
CALIBRATION
PROCEDURE
.
56
6.2
ABSOLUTE
ENERGY
CALIBRATION
WITH
BEAM
PARTICLES
.
56
6.2.1
EXPERIMENTAL
SETUP
OF
THE
BEAM
TESTS
.
56
6.2.2
CALIBRATION
WITH
ELECTRONS
.
59
6.2.3
OTHER
TESTS
WITH
ELECTRONS
.
62
6.2.4
TESTS
WITH
HADRONS
.
64
6.2.5
CALIBRATION
WITH
MUONS
.
65
7
A
HIGH
PRECISION
CALIBRATION
PROCEDURE
WITH
MUONS
66
7.1
MOTIVATION
.
66
7.2
ENERGY
LOSS
OF
MUONS
IN
MATTER
.
67
7.3
FITTING
THE
ENERGY
DISTRIBUTION
.
71
7.4
ESTIMATION
OF
THE
MEAN
VALUES
.
72
7.5
RESULTS
FOR
THE
FCAL
AND
RCAL
MODULES
CALIBRATED
AT
CERN
.
73
8
INFLUENCE
OF
MECHANICAL
TOLERANCES
ON
THE
CALORIMETER
RESPONSE
76
9
RECONSTRUCTION
OF
DEEP
INELASTIC
SCATTERING
PARAMETERS
81
9.1
INTRODUCTION
.
81
9.2
DETERMINATION
OF
STRUCTURE
FUNCTIONS
.
81
9.2.1
ELASTIC
ELECTRON
PROTON
SCATTERING
.
81
9.3
DEEP
INELASTIC
SCATTERING
CROSS
SECTIONS
.
82
9.3.1
DETERMINATION
OF
STRUCTURE
FUNCTIONS
.
83
9.4
RECONSTRUCTION
METHODS
FOR
DIS
VARIABLES
.
84
9.4.1
TOPOLOGY
OF
NC-REACTIONS
.
85
9.4.2
RECONSTRUCTION
USING
THE
ELECTRON
AND
THE
CURRENT
JET
.
85
9.4.3
RECONSTRUCTION
WITH
THE
METHOD
OF
JACQUET
AND
BLONDEL
.
88
9.5
INFLUENCE
OF
THE
DETECTOR
ON
THE
X
-
Y
RECONSTRUCTION
'
.
88
9.5.1
INTRODUCTION
.
88
9.5.2
RESULTS
.
90
9.5.3
SUMMARY
.
103
9.6
EFFECTS
OF
CALIBRATION
ERRORS
AND
NOISE
.
108
9.6.1
NOISE
.
109
9.6.2
CALIBRATION
UNCERTAINTIES
.
ILL
9.7
SUMMARY
OF
RECONSTRUCTION
ERRORS
.
118
10
CONCLUSION
119
A
SOFTWARE
ENVIRONMENT
FOR
THE
MONTE
CARLO
STUDIES
120
A.L
SOFTWARE
STRUCTURE
.
120
A.2
CUTS
TO
REMOVE
CORRUPTED
EVENTS
DUE
TO
MONTE
CARLO
ERRORS
.
120
B
PARAMETERS
CHOSEN
FOR
THE
LEPTO
EVENT
GENERATOR
125
C
COMPARISON
OF
CHI-SQUARE
AND
MAXIMUM
LIKELIHOOD
FITS
128
D
DATA
FOR
NOISE
AND
CALIBRATION
UNCERTAINTIES
126
E
ACKNOWLEDGEMENTS
137
IV |
any_adam_object | 1 |
author | Woeniger, Torsten |
author_facet | Woeniger, Torsten |
author_role | aut |
author_sort | Woeniger, Torsten |
author_variant | t w tw |
building | Verbundindex |
bvnumber | BV024609762 |
classification_rvk | UN 3040 |
ctrlnum | (OCoLC)722386097 (DE-599)BVBBV024609762 |
discipline | Physik |
format | Thesis Book |
fullrecord | <?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>00000nam a2200000 c 4500</leader><controlfield tag="001">BV024609762</controlfield><controlfield tag="003">DE-604</controlfield><controlfield tag="005">20090910</controlfield><controlfield tag="007">t</controlfield><controlfield tag="008">090924s1992 d||| m||| 00||| ger d</controlfield><datafield tag="015" ind1=" " ind2=" "><subfield code="a">92,B25,0329</subfield><subfield code="2">dnb</subfield></datafield><datafield tag="016" ind1="7" ind2=" "><subfield code="a">920723225</subfield><subfield code="2">DE-101</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(OCoLC)722386097</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-599)BVBBV024609762</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-604</subfield><subfield code="b">ger</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="041" ind1="0" ind2=" "><subfield code="a">ger</subfield></datafield><datafield tag="049" ind1=" " ind2=" "><subfield code="a">DE-83</subfield><subfield code="a">DE-11</subfield></datafield><datafield tag="084" ind1=" " ind2=" "><subfield code="a">UN 3040</subfield><subfield code="0">(DE-625)145972:</subfield><subfield code="2">rvk</subfield></datafield><datafield tag="088" ind1=" " ind2=" "><subfield code="a">DESY F 35 92 01</subfield></datafield><datafield tag="100" ind1="1" ind2=" "><subfield code="a">Woeniger, Torsten</subfield><subfield code="e">Verfasser</subfield><subfield code="4">aut</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">Influence of calorimeter calibration errors on the measurement of deep inelastic scattering</subfield><subfield code="c">by T. Woeniger</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="a">Hamburg</subfield><subfield code="b">[Dt. Elektronen-Synchrotron]</subfield><subfield code="c">1992</subfield></datafield><datafield tag="300" ind1=" " ind2=" "><subfield code="a">IX, 137 Sp.</subfield><subfield code="b">graph. Darst.</subfield><subfield code="c">30 cm</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="b">txt</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="b">n</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="b">nc</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="502" ind1=" " ind2=" "><subfield code="a">Zugl.: Hamburg, Univ., Diss., 1991</subfield></datafield><datafield tag="650" ind1="0" ind2="7"><subfield code="a">Messfehler</subfield><subfield code="0">(DE-588)4133270-2</subfield><subfield code="2">gnd</subfield><subfield code="9">rswk-swf</subfield></datafield><datafield tag="650" ind1="0" ind2="7"><subfield code="a">Fehler</subfield><subfield code="0">(DE-588)4016606-5</subfield><subfield code="2">gnd</subfield><subfield code="9">rswk-swf</subfield></datafield><datafield tag="650" ind1="0" ind2="7"><subfield code="a">Kalibrieren</subfield><subfield code="g">Messtechnik</subfield><subfield code="0">(DE-588)4198763-9</subfield><subfield code="2">gnd</subfield><subfield code="9">rswk-swf</subfield></datafield><datafield tag="650" ind1="0" ind2="7"><subfield code="a">Strahlungskalorimeter</subfield><subfield code="0">(DE-588)4210218-2</subfield><subfield code="2">gnd</subfield><subfield code="9">rswk-swf</subfield></datafield><datafield tag="650" ind1="0" ind2="7"><subfield code="a">Messung</subfield><subfield code="0">(DE-588)4038852-9</subfield><subfield code="2">gnd</subfield><subfield code="9">rswk-swf</subfield></datafield><datafield tag="650" ind1="0" ind2="7"><subfield code="a">Tiefinelastische Streuung</subfield><subfield code="0">(DE-588)4185432-9</subfield><subfield code="2">gnd</subfield><subfield code="9">rswk-swf</subfield></datafield><datafield tag="650" ind1="0" ind2="7"><subfield code="a">Kalorimeter</subfield><subfield code="0">(DE-588)4163121-3</subfield><subfield code="2">gnd</subfield><subfield code="9">rswk-swf</subfield></datafield><datafield tag="655" ind1=" " ind2="7"><subfield code="0">(DE-588)4113937-9</subfield><subfield code="a">Hochschulschrift</subfield><subfield code="2">gnd-content</subfield></datafield><datafield tag="689" ind1="0" ind2="0"><subfield code="a">Tiefinelastische Streuung</subfield><subfield code="0">(DE-588)4185432-9</subfield><subfield code="D">s</subfield></datafield><datafield tag="689" ind1="0" ind2="1"><subfield code="a">Messung</subfield><subfield code="0">(DE-588)4038852-9</subfield><subfield code="D">s</subfield></datafield><datafield tag="689" ind1="0" ind2="2"><subfield code="a">Kalorimeter</subfield><subfield code="0">(DE-588)4163121-3</subfield><subfield code="D">s</subfield></datafield><datafield tag="689" ind1="0" ind2="3"><subfield code="a">Kalibrieren</subfield><subfield code="g">Messtechnik</subfield><subfield code="0">(DE-588)4198763-9</subfield><subfield code="D">s</subfield></datafield><datafield tag="689" ind1="0" ind2="4"><subfield code="a">Fehler</subfield><subfield code="0">(DE-588)4016606-5</subfield><subfield code="D">s</subfield></datafield><datafield tag="689" ind1="0" ind2=" "><subfield code="5">DE-604</subfield></datafield><datafield tag="689" ind1="1" ind2="0"><subfield code="a">Tiefinelastische Streuung</subfield><subfield code="0">(DE-588)4185432-9</subfield><subfield code="D">s</subfield></datafield><datafield tag="689" ind1="1" ind2="1"><subfield code="a">Strahlungskalorimeter</subfield><subfield code="0">(DE-588)4210218-2</subfield><subfield code="D">s</subfield></datafield><datafield tag="689" ind1="1" ind2="2"><subfield code="a">Kalibrieren</subfield><subfield code="g">Messtechnik</subfield><subfield code="0">(DE-588)4198763-9</subfield><subfield code="D">s</subfield></datafield><datafield tag="689" ind1="1" ind2=" "><subfield code="5">DE-604</subfield></datafield><datafield tag="689" ind1="2" ind2="0"><subfield code="a">Tiefinelastische Streuung</subfield><subfield code="0">(DE-588)4185432-9</subfield><subfield code="D">s</subfield></datafield><datafield tag="689" ind1="2" ind2="1"><subfield code="a">Kalorimeter</subfield><subfield code="0">(DE-588)4163121-3</subfield><subfield code="D">s</subfield></datafield><datafield tag="689" ind1="2" ind2="2"><subfield code="a">Messfehler</subfield><subfield code="0">(DE-588)4133270-2</subfield><subfield code="D">s</subfield></datafield><datafield tag="689" ind1="2" ind2=" "><subfield code="8">1\p</subfield><subfield code="5">DE-604</subfield></datafield><datafield tag="856" ind1="4" ind2="2"><subfield code="m">DNB Datenaustausch</subfield><subfield code="q">application/pdf</subfield><subfield code="u">http://bvbr.bib-bvb.de:8991/F?func=service&doc_library=BVB01&local_base=BVB01&doc_number=018582565&sequence=000001&line_number=0001&func_code=DB_RECORDS&service_type=MEDIA</subfield><subfield code="3">Inhaltsverzeichnis</subfield></datafield><datafield tag="883" ind1="1" ind2=" "><subfield code="8">1\p</subfield><subfield code="a">cgwrk</subfield><subfield code="d">20201028</subfield><subfield code="q">DE-101</subfield><subfield code="u">https://d-nb.info/provenance/plan#cgwrk</subfield></datafield><datafield tag="943" ind1="1" ind2=" "><subfield code="a">oai:aleph.bib-bvb.de:BVB01-018582565</subfield></datafield></record></collection> |
genre | (DE-588)4113937-9 Hochschulschrift gnd-content |
genre_facet | Hochschulschrift |
id | DE-604.BV024609762 |
illustrated | Illustrated |
indexdate | 2024-08-14T00:39:29Z |
institution | BVB |
language | German |
oai_aleph_id | oai:aleph.bib-bvb.de:BVB01-018582565 |
oclc_num | 722386097 |
open_access_boolean | |
owner | DE-83 DE-11 |
owner_facet | DE-83 DE-11 |
physical | IX, 137 Sp. graph. Darst. 30 cm |
publishDate | 1992 |
publishDateSearch | 1992 |
publishDateSort | 1992 |
publisher | [Dt. Elektronen-Synchrotron] |
record_format | marc |
spelling | Woeniger, Torsten Verfasser aut Influence of calorimeter calibration errors on the measurement of deep inelastic scattering by T. Woeniger Hamburg [Dt. Elektronen-Synchrotron] 1992 IX, 137 Sp. graph. Darst. 30 cm txt rdacontent n rdamedia nc rdacarrier Zugl.: Hamburg, Univ., Diss., 1991 Messfehler (DE-588)4133270-2 gnd rswk-swf Fehler (DE-588)4016606-5 gnd rswk-swf Kalibrieren Messtechnik (DE-588)4198763-9 gnd rswk-swf Strahlungskalorimeter (DE-588)4210218-2 gnd rswk-swf Messung (DE-588)4038852-9 gnd rswk-swf Tiefinelastische Streuung (DE-588)4185432-9 gnd rswk-swf Kalorimeter (DE-588)4163121-3 gnd rswk-swf (DE-588)4113937-9 Hochschulschrift gnd-content Tiefinelastische Streuung (DE-588)4185432-9 s Messung (DE-588)4038852-9 s Kalorimeter (DE-588)4163121-3 s Kalibrieren Messtechnik (DE-588)4198763-9 s Fehler (DE-588)4016606-5 s DE-604 Strahlungskalorimeter (DE-588)4210218-2 s Messfehler (DE-588)4133270-2 s 1\p DE-604 DNB Datenaustausch application/pdf http://bvbr.bib-bvb.de:8991/F?func=service&doc_library=BVB01&local_base=BVB01&doc_number=018582565&sequence=000001&line_number=0001&func_code=DB_RECORDS&service_type=MEDIA Inhaltsverzeichnis 1\p cgwrk 20201028 DE-101 https://d-nb.info/provenance/plan#cgwrk |
spellingShingle | Woeniger, Torsten Influence of calorimeter calibration errors on the measurement of deep inelastic scattering Messfehler (DE-588)4133270-2 gnd Fehler (DE-588)4016606-5 gnd Kalibrieren Messtechnik (DE-588)4198763-9 gnd Strahlungskalorimeter (DE-588)4210218-2 gnd Messung (DE-588)4038852-9 gnd Tiefinelastische Streuung (DE-588)4185432-9 gnd Kalorimeter (DE-588)4163121-3 gnd |
subject_GND | (DE-588)4133270-2 (DE-588)4016606-5 (DE-588)4198763-9 (DE-588)4210218-2 (DE-588)4038852-9 (DE-588)4185432-9 (DE-588)4163121-3 (DE-588)4113937-9 |
title | Influence of calorimeter calibration errors on the measurement of deep inelastic scattering |
title_auth | Influence of calorimeter calibration errors on the measurement of deep inelastic scattering |
title_exact_search | Influence of calorimeter calibration errors on the measurement of deep inelastic scattering |
title_full | Influence of calorimeter calibration errors on the measurement of deep inelastic scattering by T. Woeniger |
title_fullStr | Influence of calorimeter calibration errors on the measurement of deep inelastic scattering by T. Woeniger |
title_full_unstemmed | Influence of calorimeter calibration errors on the measurement of deep inelastic scattering by T. Woeniger |
title_short | Influence of calorimeter calibration errors on the measurement of deep inelastic scattering |
title_sort | influence of calorimeter calibration errors on the measurement of deep inelastic scattering |
topic | Messfehler (DE-588)4133270-2 gnd Fehler (DE-588)4016606-5 gnd Kalibrieren Messtechnik (DE-588)4198763-9 gnd Strahlungskalorimeter (DE-588)4210218-2 gnd Messung (DE-588)4038852-9 gnd Tiefinelastische Streuung (DE-588)4185432-9 gnd Kalorimeter (DE-588)4163121-3 gnd |
topic_facet | Messfehler Fehler Kalibrieren Messtechnik Strahlungskalorimeter Messung Tiefinelastische Streuung Kalorimeter Hochschulschrift |
url | http://bvbr.bib-bvb.de:8991/F?func=service&doc_library=BVB01&local_base=BVB01&doc_number=018582565&sequence=000001&line_number=0001&func_code=DB_RECORDS&service_type=MEDIA |
work_keys_str_mv | AT woenigertorsten influenceofcalorimetercalibrationerrorsonthemeasurementofdeepinelasticscattering |