Plasma source mass spectrometry: applications and emerging technologies
Gespeichert in:
Format: | Buch |
---|---|
Sprache: | English |
Veröffentlicht: |
Cambridge
Royal Soc. of Chemistry
2003
|
Schriftenreihe: | [Special publication / Royal Society of Chemistry
288] |
Schlagworte: | |
Online-Zugang: | Inhaltsverzeichnis |
Beschreibung: | Aufgrund eines techn. Fehlers fehlt die Angabe der Schriftenreihe und der Bandzählung in der Vorlage! |
Beschreibung: | X, 412 S. graph. Darst. |
ISBN: | 0854046038 |
Internformat
MARC
LEADER | 00000nam a2200000 cb4500 | ||
---|---|---|---|
001 | BV017483888 | ||
003 | DE-604 | ||
005 | 20060221 | ||
007 | t | ||
008 | 030910s2003 d||| |||| 10||| eng d | ||
020 | |a 0854046038 |9 0-85404-603-8 | ||
035 | |a (OCoLC)217156239 | ||
035 | |a (DE-599)BVBBV017483888 | ||
040 | |a DE-604 |b ger |e rakwb | ||
041 | 0 | |a eng | |
049 | |a DE-12 |a DE-91G |a DE-19 | ||
084 | |a VG 9808 |0 (DE-625)147244:261 |2 rvk | ||
084 | |a CHE 254f |2 stub | ||
245 | 1 | 0 | |a Plasma source mass spectrometry |b applications and emerging technologies |c ed. by Grenville Holland ... |
264 | 1 | |a Cambridge |b Royal Soc. of Chemistry |c 2003 | |
300 | |a X, 412 S. |b graph. Darst. | ||
336 | |b txt |2 rdacontent | ||
337 | |b n |2 rdamedia | ||
338 | |b nc |2 rdacarrier | ||
490 | 1 | |a [Special publication / Royal Society of Chemistry |v 288] | |
500 | |a Aufgrund eines techn. Fehlers fehlt die Angabe der Schriftenreihe und der Bandzählung in der Vorlage! | ||
650 | 0 | 7 | |a ICP-Massenspektrometrie |0 (DE-588)4280345-7 |2 gnd |9 rswk-swf |
655 | 7 | |0 (DE-588)1071861417 |a Konferenzschrift |y 2002 |z Durham |2 gnd-content | |
689 | 0 | 0 | |a ICP-Massenspektrometrie |0 (DE-588)4280345-7 |D s |
689 | 0 | |5 DE-604 | |
700 | 1 | |a Holland, Grenville |e Sonstige |4 oth | |
810 | 2 | |a Royal Society of Chemistry |t [Special publication |v 288] |w (DE-604)BV001896212 |9 288 | |
856 | 4 | 2 | |m Digitalisierung TU Muenchen |q application/pdf |u http://bvbr.bib-bvb.de:8991/F?func=service&doc_library=BVB01&local_base=BVB01&doc_number=010534545&sequence=000002&line_number=0001&func_code=DB_RECORDS&service_type=MEDIA |3 Inhaltsverzeichnis |
999 | |a oai:aleph.bib-bvb.de:BVB01-010534545 |
Datensatz im Suchindex
_version_ | 1804130285912064000 |
---|---|
adam_text | Contents
1.
Bio-Analytical
Applications
Simultaneous Quantitation of Specific Proteins Using ImmunoAssay ICP-MS
Zoë
A. Quinn, Vladimir
I. Baranov
and Scott D. Tanner
3
New Challenges For ICP-MS Instrumentation and Data Acquisition. Solving
Problems of Real Life Biology
Vladimir
I. Baranov,
Zoë
A. Quinn, Dmitry R.
Bandura
and Scott D. Tanner
16
Some Applications of ICP-MS in the Pharmaceutical Industry
P.S.
Marshall,
0.
Heudi,
С
Ramirez-Molina, S. Mckeown,
N.
Parr, S. Bains,
H.N. Freeman, F. Abou-Shakra
28
Quantitation of Phosphorus in Biologically Active Materials by ICP-MS
Detection of
P
and
S
with Chemical Resolution
Dmitry R.
Bandura,
Vladimir
I. Baranov,
Olga I. Ornatsky
and
Zoë
A. Quinn
43
Application of Sector-Field ICP-MS and ICP-MS with Collision Cell for
Determination of Phosphorus and Iron in Proteins
Sergei F.
Boulyga, Carola
Pickhardt, J.
Susanne
Becker, Michael Przybylski
and J.
Sabine
Becker
54
Combination of ICP-MS and Ion Exchange Chromatography Permits Analyses
of Specific Cisplatin
DNA
Modifications Formed in Cancer Cells
A. Azim-Araghi, C.J. Ottley, D.G. Pearson, and MJ. Tilby
66
Conventional and
Chromatographie ICPMS
Analysis of Cisplatin and
Carboplatin in Plasma and Plasma
Ultrafiltrate
Robbin B.
Burns and David J. Gray
74
Determination, by ICP-MS, of Background and BBR
3464
Induced Levels of
Platinum Bound to
DNA
Isolated From Blood Cells: A Comparison of the
Sensitivity of the PerkinElmer SCIEX ELAN
6000
and the ThermoFinnigan
Neptune Instruments
T. John, C.J Ottley, D.G. Pearson, G.M.
Noweli,
H.
Calven
and M.J. Tilby
82
2.
Environmental Applications
Applications of ICP-MS in Environmental Science
Thomas Prohaska, Gunda
Köllensperger, Stephan
Hann, Herhard Stingeder,
Walter
Fitz
and Walter
Wenzel 93
viii Contents
Development
of All-Ium Analytical Method for Water Samples at Lake Biwa
Y. Takaku, S. Akiba, T. Hayashi, M.
Капо,
Y. Ohtsuka
105
Iron and Arsenic Speciation in Groundwaters from West Bengal, India by
Coupled HPLC-ICP-MS Utilising a Hexapole Collision Cell
Andrew G. Gault, Lois E. Davidson, Paul R. Lythgoe, David A. Poly a,
Fadi R. Abou-Shakra, Heather J. Walker and Debashis Chatterjee
112
Coupled HPLC-ICP-MS Analysis Indicates Highly Hazardous
Concentrations of Dissolved Arsenic Species in Cambodian Groundwaters
David A. Polya, Andrew G. Gault, Nicola J. Bourne, Paul R. Lythgoe and
David A. Cooke
127
An Old Problem of Lead Contamination
T.D.B. Lyon,
R.
Ellam and
С.
Ramsay
141
The Use of Different Enriched Isotope Mixtures for the Determination
of Butyltin Compounds in Environmental Samples Using Isotope Dilution
GC-ICP-MS
Pablo
Rodríguez-González,
Jorge Ruiz
Encinar,
J.
Ignacio García Alonso
and A If redo Sanz-Medel
148
Determination of Cerium, Lead and Uranium in Bivalve Shells Using an
Iminodiacetate Based Preconcentration System and ICP-MS
Ted McGowan and Noel Casey
160
New Applications for GC-ICP-MS; Beyond Sensitive, Selective Analysis
of Organometallic Species
E. McCurdy, S. Wilbur, G. Woods andD. Potter
168
The Use of a High Accuracy Isotope Dilution Mass Spectrometry (IDMS)
Method for the Analysis of Sulfur in Fuel to Support Analytical Technologies
used in Industry
R. Hearn and P. Evans
185
3.
Archaeological Applications
Anglo-Saxon Residential Mobility at West Heslerton, North Yorkshire, UK
from Combined O- and Sr-Isotope Analysis.
Paul Budd, Carolyn Chenery, Janet Montgomery, Jane Evans and
Dominic Powlesland
195
The Use of ICP-MS in Provenancing Igneous Stone Artefacts: Examples
from the Southern Levant
G.P.
Rutter,
D.G. Pearson, G. Philip, J.M.D. Day and C.J. Ottley
209
Contents ix
4.
Preparatory and Delivery Methods
A Routine Method for the Dissolution of Geological Samples for the
Analysis of REE and Trace Elements via ICP-MS
C.J. Ottley, D. G. Pearson and G.J. Irvine
22
1
Calculation Methods for the Determination of Isotope Ratios of Transient
Signals of Volatile
Organometall
ic
Compounds
Silvia Wehmeier, Rob Ellam and
Jörg Feldmann 231
The Uncertainty in REE Determination in Urine By ETV- ICP -MS
:
A New
Approach to Data Evaluation
5.
Spezia,
M.
Bettinelli,
A. Ronchi,
С.
Minoia
240
Trapped Ablation Mode in Laser Ablation ICPMS Experiments for the
Enhancement of the Signal-To-Noise Ratio
Davide
Bleiner
and
Detlef Günther 249
5.
Reaction Cells and Collision Cells
Overcoming Spectral Overlaps: Quadrupole ICP-MS with Reaction Cell and
Sector Based ICP-MS
John W. Olesik and Deanna Jones
261
Determination of Selenium in Biological Samples by Isotope Dilution
Analysis Octapole Reaction System ICP-MS
J.M.
Marchante-Gayón,
L. Hinojosa
Reyes, J.I.
García Alonso
and
A. Sanz-Medel
271
The York University Ion-Molecule Reaction Database: A Biennial Report
Gregory K. Koyanagi,
Vitali
V. Lavrov and Diethard K.
Böhme 282
Determination of
Fé, Ni, Co,
Cu andZn in High
-Са
Samples Using Methane
as a Reaction Cell Gas
Scott D. Tanner and Dmitry R.
Bandura
292
6.
MultiCoIIectors
Long-Term Performance Characteristics of a Plasma
Ionisation
Multi-Collector
Mass Spectrometer (PIMMS): The ThermoFinnigan Neptune
G.M.
Noweli,
D.G. Pearson, C.J. Ottley, J. Schwieters and D.
Dowali
307
χ
Contents
Chemical Pre-Concentration
Procedures
for High-Precision Analysis of Hf-Nd-Sr
Isotopes in Geological Materials by Plasma
Ionisation
Multi-Collector Mass
Spectrometry (PIMMS) Techniques
D.P.
Dowali,
G.M.
Noweli
and D.G. Pearson
321
High Precision MC-ICPMS Measurement of Silver
Isotopie
Compositions
Sarah Woodland, Mark
Rehkämper, Der-Chuen
Lee and Alex
N.
Halliday
338
Precise and Accurate Determination of Iron Isotopes by Multi-Collector
Inductively Coupled Plasma Mass Spectrometry
E. Mullane,
S.S.
Russell, M. Gounelle, T. Mason, V. Din, D. Weiss andB. Coles
351
Measurement of Os Isotopes Using Plasma
Ionisation
Multi-Collector
Mass Spectrometry and a Suggested Scheme for the Accurate Determination
of Interfering Element Ratios
D.G. Pearson and G.M.
Noweli
362
High Precision Rhenium and Platinum Isotope Dilution Analyses by
Plasma
Ionisation Multicollector
Mass Spectrometry
J.M.D. Day, D.G. Pearson and G.M.
Noweli
374
Uranium and Thorium Isotope Ratio Measurements Using Multiple
Collector Inductively Coupled Plasma Mass Spectrometry with
Multi-Ion-Counting Detectors
R.M. Ellam and A. W Tudhope
391
Author Index
404
Subject Index
407
|
any_adam_object | 1 |
building | Verbundindex |
bvnumber | BV017483888 |
classification_rvk | VG 9808 |
classification_tum | CHE 254f |
ctrlnum | (OCoLC)217156239 (DE-599)BVBBV017483888 |
discipline | Chemie / Pharmazie Chemie |
format | Book |
fullrecord | <?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01642nam a2200373 cb4500</leader><controlfield tag="001">BV017483888</controlfield><controlfield tag="003">DE-604</controlfield><controlfield tag="005">20060221 </controlfield><controlfield tag="007">t</controlfield><controlfield tag="008">030910s2003 d||| |||| 10||| eng d</controlfield><datafield tag="020" ind1=" " ind2=" "><subfield code="a">0854046038</subfield><subfield code="9">0-85404-603-8</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(OCoLC)217156239</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-599)BVBBV017483888</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-604</subfield><subfield code="b">ger</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="041" ind1="0" ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="049" ind1=" " ind2=" "><subfield code="a">DE-12</subfield><subfield code="a">DE-91G</subfield><subfield code="a">DE-19</subfield></datafield><datafield tag="084" ind1=" " ind2=" "><subfield code="a">VG 9808</subfield><subfield code="0">(DE-625)147244:261</subfield><subfield code="2">rvk</subfield></datafield><datafield tag="084" ind1=" " ind2=" "><subfield code="a">CHE 254f</subfield><subfield code="2">stub</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">Plasma source mass spectrometry</subfield><subfield code="b">applications and emerging technologies</subfield><subfield code="c">ed. by Grenville Holland ...</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="a">Cambridge</subfield><subfield code="b">Royal Soc. of Chemistry</subfield><subfield code="c">2003</subfield></datafield><datafield tag="300" ind1=" " ind2=" "><subfield code="a">X, 412 S.</subfield><subfield code="b">graph. Darst.</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="b">txt</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="b">n</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="b">nc</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="490" ind1="1" ind2=" "><subfield code="a">[Special publication / Royal Society of Chemistry</subfield><subfield code="v">288]</subfield></datafield><datafield tag="500" ind1=" " ind2=" "><subfield code="a">Aufgrund eines techn. Fehlers fehlt die Angabe der Schriftenreihe und der Bandzählung in der Vorlage!</subfield></datafield><datafield tag="650" ind1="0" ind2="7"><subfield code="a">ICP-Massenspektrometrie</subfield><subfield code="0">(DE-588)4280345-7</subfield><subfield code="2">gnd</subfield><subfield code="9">rswk-swf</subfield></datafield><datafield tag="655" ind1=" " ind2="7"><subfield code="0">(DE-588)1071861417</subfield><subfield code="a">Konferenzschrift</subfield><subfield code="y">2002</subfield><subfield code="z">Durham</subfield><subfield code="2">gnd-content</subfield></datafield><datafield tag="689" ind1="0" ind2="0"><subfield code="a">ICP-Massenspektrometrie</subfield><subfield code="0">(DE-588)4280345-7</subfield><subfield code="D">s</subfield></datafield><datafield tag="689" ind1="0" ind2=" "><subfield code="5">DE-604</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Holland, Grenville</subfield><subfield code="e">Sonstige</subfield><subfield code="4">oth</subfield></datafield><datafield tag="810" ind1="2" ind2=" "><subfield code="a">Royal Society of Chemistry</subfield><subfield code="t">[Special publication</subfield><subfield code="v">288]</subfield><subfield code="w">(DE-604)BV001896212</subfield><subfield code="9">288</subfield></datafield><datafield tag="856" ind1="4" ind2="2"><subfield code="m">Digitalisierung TU Muenchen</subfield><subfield code="q">application/pdf</subfield><subfield code="u">http://bvbr.bib-bvb.de:8991/F?func=service&doc_library=BVB01&local_base=BVB01&doc_number=010534545&sequence=000002&line_number=0001&func_code=DB_RECORDS&service_type=MEDIA</subfield><subfield code="3">Inhaltsverzeichnis</subfield></datafield><datafield tag="999" ind1=" " ind2=" "><subfield code="a">oai:aleph.bib-bvb.de:BVB01-010534545</subfield></datafield></record></collection> |
genre | (DE-588)1071861417 Konferenzschrift 2002 Durham gnd-content |
genre_facet | Konferenzschrift 2002 Durham |
id | DE-604.BV017483888 |
illustrated | Illustrated |
indexdate | 2024-07-09T19:18:37Z |
institution | BVB |
isbn | 0854046038 |
language | English |
oai_aleph_id | oai:aleph.bib-bvb.de:BVB01-010534545 |
oclc_num | 217156239 |
open_access_boolean | |
owner | DE-12 DE-91G DE-BY-TUM DE-19 DE-BY-UBM |
owner_facet | DE-12 DE-91G DE-BY-TUM DE-19 DE-BY-UBM |
physical | X, 412 S. graph. Darst. |
publishDate | 2003 |
publishDateSearch | 2003 |
publishDateSort | 2003 |
publisher | Royal Soc. of Chemistry |
record_format | marc |
series2 | [Special publication / Royal Society of Chemistry |
spelling | Plasma source mass spectrometry applications and emerging technologies ed. by Grenville Holland ... Cambridge Royal Soc. of Chemistry 2003 X, 412 S. graph. Darst. txt rdacontent n rdamedia nc rdacarrier [Special publication / Royal Society of Chemistry 288] Aufgrund eines techn. Fehlers fehlt die Angabe der Schriftenreihe und der Bandzählung in der Vorlage! ICP-Massenspektrometrie (DE-588)4280345-7 gnd rswk-swf (DE-588)1071861417 Konferenzschrift 2002 Durham gnd-content ICP-Massenspektrometrie (DE-588)4280345-7 s DE-604 Holland, Grenville Sonstige oth Royal Society of Chemistry [Special publication 288] (DE-604)BV001896212 288 Digitalisierung TU Muenchen application/pdf http://bvbr.bib-bvb.de:8991/F?func=service&doc_library=BVB01&local_base=BVB01&doc_number=010534545&sequence=000002&line_number=0001&func_code=DB_RECORDS&service_type=MEDIA Inhaltsverzeichnis |
spellingShingle | Plasma source mass spectrometry applications and emerging technologies ICP-Massenspektrometrie (DE-588)4280345-7 gnd |
subject_GND | (DE-588)4280345-7 (DE-588)1071861417 |
title | Plasma source mass spectrometry applications and emerging technologies |
title_auth | Plasma source mass spectrometry applications and emerging technologies |
title_exact_search | Plasma source mass spectrometry applications and emerging technologies |
title_full | Plasma source mass spectrometry applications and emerging technologies ed. by Grenville Holland ... |
title_fullStr | Plasma source mass spectrometry applications and emerging technologies ed. by Grenville Holland ... |
title_full_unstemmed | Plasma source mass spectrometry applications and emerging technologies ed. by Grenville Holland ... |
title_short | Plasma source mass spectrometry |
title_sort | plasma source mass spectrometry applications and emerging technologies |
title_sub | applications and emerging technologies |
topic | ICP-Massenspektrometrie (DE-588)4280345-7 gnd |
topic_facet | ICP-Massenspektrometrie Konferenzschrift 2002 Durham |
url | http://bvbr.bib-bvb.de:8991/F?func=service&doc_library=BVB01&local_base=BVB01&doc_number=010534545&sequence=000002&line_number=0001&func_code=DB_RECORDS&service_type=MEDIA |
volume_link | (DE-604)BV001896212 |
work_keys_str_mv | AT hollandgrenville plasmasourcemassspectrometryapplicationsandemergingtechnologies |