Primärstabilität eines Zementendoprothesenschafts: vergleichende Messungen an humanen Leichenfemora
Saved in:
Main Author: | |
---|---|
Format: | Book |
Language: | German |
Published: |
1995
|
Subjects: | |
Online Access: | Inhaltsverzeichnis |
Item Description: | München, Univ., Med.Fak., Diss., 1995 |
Physical Description: | 80 S. Ill., graph. Darst. |
Staff View
MARC
LEADER | 00000nam a2200000 c 4500 | ||
---|---|---|---|
001 | BV010214927 | ||
003 | DE-604 | ||
005 | 19950808 | ||
007 | t | ||
008 | 950608s1995 ad|| m||| 00||| gerod | ||
016 | 7 | |a 944820085 |2 DE-101 | |
035 | |a (OCoLC)64525882 | ||
035 | |a (DE-599)BVBBV010214927 | ||
040 | |a DE-604 |b ger |e rakddb | ||
041 | 0 | |a ger | |
049 | |a DE-19 |a DE-355 |a DE-12 |a DE-154 |a DE-11 | ||
084 | |a 610 |2 sdnb | ||
100 | 1 | |a Sailer, Fritz Peter |e Verfasser |4 aut | |
245 | 1 | 0 | |a Primärstabilität eines Zementendoprothesenschafts |b vergleichende Messungen an humanen Leichenfemora |c vorgelegt von Fritz Peter Sailer |
264 | 1 | |c 1995 | |
300 | |a 80 S. |b Ill., graph. Darst. | ||
336 | |b txt |2 rdacontent | ||
337 | |b n |2 rdamedia | ||
338 | |b nc |2 rdacarrier | ||
500 | |a München, Univ., Med.Fak., Diss., 1995 | ||
655 | 7 | |0 (DE-588)4113937-9 |a Hochschulschrift |2 gnd-content | |
856 | 4 | 2 | |m DNB Datenaustausch |q application/pdf |u http://bvbr.bib-bvb.de:8991/F?func=service&doc_library=BVB01&local_base=BVB01&doc_number=006787958&sequence=000001&line_number=0001&func_code=DB_RECORDS&service_type=MEDIA |3 Inhaltsverzeichnis |
943 | 1 | |a oai:aleph.bib-bvb.de:BVB01-006787958 |
Record in the Search Index
_version_ | 1807323882946822144 |
---|---|
adam_text |
1.
EINLEITUNG
1
L.L.ENDOPROTHETISCH
VERANKERUNG
ALT
KNOCHENZEMENT
1
1.1.1.
ASEPTISCHE
LOCKERUNGEN
2
1.1.2.
ANFORDERUNGEN
AN
DEN
KNOCHENZEMENT
UND
AN
DIE
ZEMENTIERTECHNIKEN
ALS
ENTSCHEIDENDE
FAKTOREN
FUER
DEN
ERFOLGREICHEN
HUFTGELENKERSATZ
5
1.1.3.
EINFLUSS
AUF
DIE
STABILITAET
UND
LANGZEITERGEBNISSE
8
1.2
.BISHERIG
ZEMENTIERTECHNIKEN
9
1.2.1.
HISTORISCHE
ENTWICKLUNG
9
1.2.2.
VERBESSERUNGEN
DER
ZEMENTIERTECHNIKEN
10
1.2.3.
WEITERHIN
BEOBACHTETE
MAENGEL
14
1.3.ZEMENTKANALMETHODE
15
1.4.
VERSUCHSPLANUNG
17
1.4.1.
FRAGESTELLUNG
17
1.4.2
.VERSUCHSDURCHFUEHRUNG
18
1.4.3.
DOKUMENTATION
21
1.4.4.
STATISTISCHE
RAHMENBEDINGUNGEN
22
2.
MATERIAL
UND
METHODIK
24
2.1.
ZEMENT
UND
SAUGKANALPROTHESE
24
2.1.1.BESTANDTEILE
24
2.1.2.
FUNKTION
DER
BESTANDTEILE
25
2.2.
UNTERSUCHUNGSMATERIAL
UND
INSTRUMENTARIUM
27
2.2.1.LEICHENFEMORA
-
BEHANDLUNG
DER
PRAEPARATE
27
2.2.2.
WEITERES
INSTRUMENTARIUM
2
7
2.2.2.1.
BLUTFLUSSSIMULATION
27
2.2.2.2
.KNOCHENZEMENT
29
2.2.2.3.
ZEMENTDRUCKSPRITZE
29
2.2.2.4.
SPEZIELLE
REIBAHLE
30
2.2.2.5.
ABSAUGPUMPE
31
2.2.2.6.
UNIVERSALPRUEFMASCHINE
32
2.3.
VORVERSUCH
3
5
2.3.1.
ZUG-DRUCKMESSUNG
IN
DER
UNIVERSALPRUEF
MASCHINE
UND
DIE
FIXIERUNG
DER
PRAEPARATE
35
2.3.2.BLUTFLUSSSIMULATION
37
2.3.3.
KORREKTE
FUNKTION
DER
ABSAUGPUMPE
38
2.3.4.
BEARBEITUNG
DER
STYLEX
R
-EINMALSPRITZEN
39
2.3.5.
VORBEREITUNG
DER
OSSA
FEMORA
FUER
DIE
IMPLANTATION
39
2.3.6.
ENTWICKLUNG
DER
PROTHESENMODELLE
40
2.3.7.
REINIGUNG
DER
PROTHESE
40
2.4
.VERSUCHSDURCHFUEHRUNG
UND
AUSWERTUNG
41
2.4.1.
LINKS/RECHTS
ZUFALLSAUSWAHL
41
2.4.2.
PRAEPARATION
,
OSTEOTOMIE
UND
BOHRUNGEN
DES
KNOCHENS
42
2.4.3.
WASSERBEUTELTECHNIK
45
2.4.4.
ABSAUGPUMPE
46
2.4.5.
EINSETZEN
DER
PROTHESE
IN
DAS
VORBEREITETE
FEMUR
47
2.4.6.
ZEMENTZUBEREITUNG
47
2.4.7.
ZEMENTIERUNG
DER
PROTHESE
48
2.4.8.
ROENTGENDOKUMENTATION
4
9
2.4.9.
MESSUNG
DER
PRIMAERSTABILITAET
IN
DER
UNIVERSALPRUEFMASCHINE
49
2.4.10.
VORBEREITUNG
DER
PROTHESE
51
3.
ERGEBNISSE
52
3.1.
EINZELMESSERGEBNISSE
52
3.1.2.
GRAPHISCHE
DARSTELLUNG
53
3.2.
VERGLEICH
DER
ERRECHNETEN
MITTELWERTE
UND
MEDIANE
55
3.2.1.
VERGLEICH
DER
ZEMENTKANALMETHODE
MIT
DER
KONVENTIONELLEN
SAUGMETHODE
55
3.2.1.1.
EINPRESSDRUCK
0,5
BAR:
55
3.2.1.2.
EINPRESSDRUCK
VON
1,5
BAR
56
3.2.2.
VERGLEICH
DER
BEIDEN
ZEMENTKANALMETHODEN
(0,5
UND
1,5
BAR
EINPRESSDRUCK)
57
3.3
.STATISTIK
58
3.3.1.
VORZEICHEN-RANG-TEST
VON
WILCOXON
58
3.3.1.1.BESCHREIBUNG
58
3.3.1.2.
ERGEBNISSE
59
3.3.2.
MAXIMUM-TEST
FUER
PAARDIFFERENZEN
60
3.3.2.1.BESCHREIBUNG
60
3.3.2.2.
ERGEBNISSE
61
4.
DISKUSSION
62
4.1.
EINLEITUNG
62
4.2.
MATERIAL
UND
METHODE
64
4.3.
ERGEBNISSE
66
5.
ZUSAMMENFASSUNG
6
7
5.1.ZEMENTKANALMETHODE
67
5.2.
VERSUCHSABLAUF
67
5.3.
ERGEBNISSE
68
5.4.
DISKUSSION
68
5.5.
AUSBLICK
68
6.
LITERATURVERZEICHNIS
70
7.
ANHANG
74
7.
L.VERAAIAHNIA
DER
TABELLEN
74
7.2.VERAEICLMIA
DER
GRAPHIKEN
74
7.3.TERSEICHNIA
DER
ABBILDUNGEN
75
STICHWORTREGISTER
76
LEBENSLAUF
BO |
any_adam_object | 1 |
author | Sailer, Fritz Peter |
author_facet | Sailer, Fritz Peter |
author_role | aut |
author_sort | Sailer, Fritz Peter |
author_variant | f p s fp fps |
building | Verbundindex |
bvnumber | BV010214927 |
ctrlnum | (OCoLC)64525882 (DE-599)BVBBV010214927 |
discipline | Medizin |
format | Book |
fullrecord | <?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>00000nam a2200000 c 4500</leader><controlfield tag="001">BV010214927</controlfield><controlfield tag="003">DE-604</controlfield><controlfield tag="005">19950808</controlfield><controlfield tag="007">t</controlfield><controlfield tag="008">950608s1995 ad|| m||| 00||| gerod</controlfield><datafield tag="016" ind1="7" ind2=" "><subfield code="a">944820085</subfield><subfield code="2">DE-101</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(OCoLC)64525882</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-599)BVBBV010214927</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-604</subfield><subfield code="b">ger</subfield><subfield code="e">rakddb</subfield></datafield><datafield tag="041" ind1="0" ind2=" "><subfield code="a">ger</subfield></datafield><datafield tag="049" ind1=" " ind2=" "><subfield code="a">DE-19</subfield><subfield code="a">DE-355</subfield><subfield code="a">DE-12</subfield><subfield code="a">DE-154</subfield><subfield code="a">DE-11</subfield></datafield><datafield tag="084" ind1=" " ind2=" "><subfield code="a">610</subfield><subfield code="2">sdnb</subfield></datafield><datafield tag="100" ind1="1" ind2=" "><subfield code="a">Sailer, Fritz Peter</subfield><subfield code="e">Verfasser</subfield><subfield code="4">aut</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">Primärstabilität eines Zementendoprothesenschafts</subfield><subfield code="b">vergleichende Messungen an humanen Leichenfemora</subfield><subfield code="c">vorgelegt von Fritz Peter Sailer</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">1995</subfield></datafield><datafield tag="300" ind1=" " ind2=" "><subfield code="a">80 S.</subfield><subfield code="b">Ill., graph. Darst.</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="b">txt</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="b">n</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="b">nc</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="500" ind1=" " ind2=" "><subfield code="a">München, Univ., Med.Fak., Diss., 1995</subfield></datafield><datafield tag="655" ind1=" " ind2="7"><subfield code="0">(DE-588)4113937-9</subfield><subfield code="a">Hochschulschrift</subfield><subfield code="2">gnd-content</subfield></datafield><datafield tag="856" ind1="4" ind2="2"><subfield code="m">DNB Datenaustausch</subfield><subfield code="q">application/pdf</subfield><subfield code="u">http://bvbr.bib-bvb.de:8991/F?func=service&doc_library=BVB01&local_base=BVB01&doc_number=006787958&sequence=000001&line_number=0001&func_code=DB_RECORDS&service_type=MEDIA</subfield><subfield code="3">Inhaltsverzeichnis</subfield></datafield><datafield tag="943" ind1="1" ind2=" "><subfield code="a">oai:aleph.bib-bvb.de:BVB01-006787958</subfield></datafield></record></collection> |
genre | (DE-588)4113937-9 Hochschulschrift gnd-content |
genre_facet | Hochschulschrift |
id | DE-604.BV010214927 |
illustrated | Illustrated |
indexdate | 2024-08-14T01:19:27Z |
institution | BVB |
language | German |
oai_aleph_id | oai:aleph.bib-bvb.de:BVB01-006787958 |
oclc_num | 64525882 |
open_access_boolean | |
owner | DE-19 DE-BY-UBM DE-355 DE-BY-UBR DE-12 DE-154 DE-11 |
owner_facet | DE-19 DE-BY-UBM DE-355 DE-BY-UBR DE-12 DE-154 DE-11 |
physical | 80 S. Ill., graph. Darst. |
publishDate | 1995 |
publishDateSearch | 1995 |
publishDateSort | 1995 |
record_format | marc |
spelling | Sailer, Fritz Peter Verfasser aut Primärstabilität eines Zementendoprothesenschafts vergleichende Messungen an humanen Leichenfemora vorgelegt von Fritz Peter Sailer 1995 80 S. Ill., graph. Darst. txt rdacontent n rdamedia nc rdacarrier München, Univ., Med.Fak., Diss., 1995 (DE-588)4113937-9 Hochschulschrift gnd-content DNB Datenaustausch application/pdf http://bvbr.bib-bvb.de:8991/F?func=service&doc_library=BVB01&local_base=BVB01&doc_number=006787958&sequence=000001&line_number=0001&func_code=DB_RECORDS&service_type=MEDIA Inhaltsverzeichnis |
spellingShingle | Sailer, Fritz Peter Primärstabilität eines Zementendoprothesenschafts vergleichende Messungen an humanen Leichenfemora |
subject_GND | (DE-588)4113937-9 |
title | Primärstabilität eines Zementendoprothesenschafts vergleichende Messungen an humanen Leichenfemora |
title_auth | Primärstabilität eines Zementendoprothesenschafts vergleichende Messungen an humanen Leichenfemora |
title_exact_search | Primärstabilität eines Zementendoprothesenschafts vergleichende Messungen an humanen Leichenfemora |
title_full | Primärstabilität eines Zementendoprothesenschafts vergleichende Messungen an humanen Leichenfemora vorgelegt von Fritz Peter Sailer |
title_fullStr | Primärstabilität eines Zementendoprothesenschafts vergleichende Messungen an humanen Leichenfemora vorgelegt von Fritz Peter Sailer |
title_full_unstemmed | Primärstabilität eines Zementendoprothesenschafts vergleichende Messungen an humanen Leichenfemora vorgelegt von Fritz Peter Sailer |
title_short | Primärstabilität eines Zementendoprothesenschafts |
title_sort | primarstabilitat eines zementendoprothesenschafts vergleichende messungen an humanen leichenfemora |
title_sub | vergleichende Messungen an humanen Leichenfemora |
topic_facet | Hochschulschrift |
url | http://bvbr.bib-bvb.de:8991/F?func=service&doc_library=BVB01&local_base=BVB01&doc_number=006787958&sequence=000001&line_number=0001&func_code=DB_RECORDS&service_type=MEDIA |
work_keys_str_mv | AT sailerfritzpeter primarstabilitateineszementendoprothesenschaftsvergleichendemessungenanhumanenleichenfemora |